Do not exceed the Measurement Category (CAT) rating of 
the lowest rated individual component of a Product, probe, 
or accessory. 

 

High voltages and currents can be present in adjacent 
circuits under test. 

 

Do not use the Product above its rated frequency. 

 

Use the Product only on insulated conductors. Use caution 
around bare conductors or bus bars. Do not touch the 
conductor. 

Symbols 

The table below is a list of the symbols used on the Probe and in the 
instructions. 

Symbol Description 

W

 

WARNING - RISK OF DANGER. Consult user 
documentation. 

X

 

WARNING. HAZARDOUS VOLTAGE. Risk of 
electric shock. 

-

 

Do not apply around or remove from uninsulated 
hazardous live conductors without taking additional 
protective measures. 

 

T

 

Double Insulated 

 

Measurement Category II is applicable to test and 
measuring circuits connected directly to utilization 
points (socket outlets and similar points) of the low-
voltage MAINS installation. 

 

Measurement Category III is applicable to test and 
measuring circuits connected to the distribution part 
of the building’s low-voltage MAINS installation. 

 

Measurement Category IV is applicable to test and 
measuring circuits connected at the source of the 
building’s low-voltage MAINS installation. 

P

 

Conforms to European Union directives. 

)

 

Certified by CSA Group to North American safety 
standards. 

 

Conforms to relevant Australian safety and EMC 
standards. 

~

 

This product complies with the WEEE Directive 
marking requirements. The affixed label indicates 
that you must not discard this electrical/electronic 
product in domestic household waste. Product 
Category: With reference to the equipment types in 
the WEEE Directive Annex I, this product is classed 
as category 9 "Monitoring and Control 
Instrumentation" product. Do not dispose of this 
product as unsorted municipal waste. 

Содержание i430-Flexi-TF-II

Страница 1: ...heck the user documentation of your test tool for compatibility before you use this current sensor Available versions are i430 Flexi TF II 61 cm 24 inch i430 Flexi TFII 48 122 cm 48 inch Contacting Fluke To contact Fluke call one of the following telephone numbers Technical Support USA 1 800 44 FLUKE 1 800 443 5853 Calibration Repair USA 1 888 99 FLUKE 1 888 993 5853 Canada 1 800 36 FLUKE 1 800 36...

Страница 2: ...ductors are exposed Limit operation to the specified measurement category voltage or current ratings De energize the circuit or wear personal protective equipment in compliance with local requirements before you apply or remove the Product Do not touch voltages 30 V ac 42 V ac peak or 60 V dc Do not use the Product around explosive gas vapor or in damp or wet environments Do not use the Product if...

Страница 3: ...cuits connected directly to utilization points socket outlets and similar points of the low voltage MAINS installation Measurement Category III is applicable to test and measuring circuits connected to the distribution part of the building s low voltage MAINS installation Measurement Category IV is applicable to test and measuring circuits connected at the source of the building s low voltage MAIN...

Страница 4: ...low these instructions 1 Connect the BNC connector of the i430 Flexi TF II to the input on the Fluke 430 series Power Quality Analyzer 2 Wear protective equipment or de energize the circuit before you connect the flexible probe around the conductor See Figure 1 C B A 1 3 1 3 1 3 D hcf157 eps Figure 1 3 Re energize the circuit if not energized 4 Center the conductor perpendicularly inside the flexi...

Страница 5: ...y Remove the input signals before you clean the Product Have an approved technician repair the Product The flexible probe and its latching system require no special care For routine maintenance 1 Ensure that no foreign body obstructs the latching mechanism 2 Clean the Probe with a damp cloth and a mild detergent Do not use abrasives solvents or alcohol 3 Do not immerse the Probe in liquids If the ...

Страница 6: ...f reading at 10 to 100 of range Noise 1 mV rms at 10 Hz to 10 kHz Additional errors temperature coefficient over operating temperature range for 24 inch model 0 02 of reading C 0 011 F for 48 inch model 0 035 of reading C 0 02 F with position of conductor in the probe window see Figure 1 Zone A Zone B Zone C 0 5 to 30 A 0 5 of reading 1 0 of reading 2 0 of reading 1 count or 0 1 A whichever is gre...

Страница 7: ...er fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Fluke s behalf To obtain service during the warranty period contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that Service Cen...

Отзывы: