Fluke i430-Flexi-TF-II Скачать руководство пользователя страница 1

PN 4426307 (4822 872 30932 – Rev.3)             

December 2011, Rev.3, 9/15 
© 2011-2015 Fluke Corporation. All rights 
reserved. Specifications are subject to change 
without notice. All product names are 
trademarks of their respective companies.      

i430-Flexi-TF-II 

6000 A Flexible 

AC Current Probe 

Instructions 

Introduction 

The i430-Flexi-TF-II (the Probe or Product) is a flexible AC current probe 
for use with the Fluke 430 series I and II Power Quality Analyzers and 
other dedicated test tools. The i430-Flexi-TF-II is optimized for current 
measurement on thick and hard to reach conductors. Check the user 
documentation of your test tool for compatibility before you use this 
current sensor. 
Available versions are: 

i430-Flexi-TF-II

61 cm (24 inch) 

i430-Flexi-TFII-48

122 cm (48 inch) 

Contacting Fluke 

To contact Fluke, call one of the following telephone numbers: 

Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)

Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)

Canada: 

1-800-36-FLUKE 

(1-800-363-5853)

Europe: +31 402-675-200

Japan: 

+81-3-6714-3114

Singapore: 

+65-6799-5566

Anywhere in the world: +1-425-446-5500

Or, visit Fluke's website at 

www.fluke.com

.

To register your product, visit 

http://register.fluke.com

.

To view, print, or download the latest manual supplement, visit

http://us.fluke.com/usen/support/manuals

.

To locate an authorized service center, go to 

www.fluke.com

Содержание i430-Flexi-TF-II

Страница 1: ...heck the user documentation of your test tool for compatibility before you use this current sensor Available versions are i430 Flexi TF II 61 cm 24 inch i430 Flexi TFII 48 122 cm 48 inch Contacting Fluke To contact Fluke call one of the following telephone numbers Technical Support USA 1 800 44 FLUKE 1 800 443 5853 Calibration Repair USA 1 888 99 FLUKE 1 888 993 5853 Canada 1 800 36 FLUKE 1 800 36...

Страница 2: ...ductors are exposed Limit operation to the specified measurement category voltage or current ratings De energize the circuit or wear personal protective equipment in compliance with local requirements before you apply or remove the Product Do not touch voltages 30 V ac 42 V ac peak or 60 V dc Do not use the Product around explosive gas vapor or in damp or wet environments Do not use the Product if...

Страница 3: ...cuits connected directly to utilization points socket outlets and similar points of the low voltage MAINS installation Measurement Category III is applicable to test and measuring circuits connected to the distribution part of the building s low voltage MAINS installation Measurement Category IV is applicable to test and measuring circuits connected at the source of the building s low voltage MAIN...

Страница 4: ...low these instructions 1 Connect the BNC connector of the i430 Flexi TF II to the input on the Fluke 430 series Power Quality Analyzer 2 Wear protective equipment or de energize the circuit before you connect the flexible probe around the conductor See Figure 1 C B A 1 3 1 3 1 3 D hcf157 eps Figure 1 3 Re energize the circuit if not energized 4 Center the conductor perpendicularly inside the flexi...

Страница 5: ...y Remove the input signals before you clean the Product Have an approved technician repair the Product The flexible probe and its latching system require no special care For routine maintenance 1 Ensure that no foreign body obstructs the latching mechanism 2 Clean the Probe with a damp cloth and a mild detergent Do not use abrasives solvents or alcohol 3 Do not immerse the Probe in liquids If the ...

Страница 6: ...f reading at 10 to 100 of range Noise 1 mV rms at 10 Hz to 10 kHz Additional errors temperature coefficient over operating temperature range for 24 inch model 0 02 of reading C 0 011 F for 48 inch model 0 035 of reading C 0 02 F with position of conductor in the probe window see Figure 1 Zone A Zone B Zone C 0 5 to 30 A 0 5 of reading 1 0 of reading 2 0 of reading 1 count or 0 1 A whichever is gre...

Страница 7: ...er fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Fluke s behalf To obtain service during the warranty period contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that Service Cen...

Отзывы: