Fluke i400s Скачать руководство пользователя страница 8

i400s 

Calibration Information 

LIMITED WARRANTY AND LIMITATION OF LIABILITY

 

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period 

is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only 

to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any 

product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of 

operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days 

and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without 

interruption. 
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to 

extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke 

authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs 

of repair/replacement parts when product purchased in one country is submitted for repair in another country. 
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective 

product which is returned to a Fluke authorized service center within the warranty period. 
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, then send the 

product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk 

for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke 

determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal condition of operation or handling, 

including overvoltage failures caused by use outside the product’s specified rating, or normal wear and tear of mechanical components, 

Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be 

returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping 

Point). 
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR 

IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 

PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR 

LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. 
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or 

consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is 

held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or 

enforceability of any other provision. 
 

www.

.com

[email protected]

1.800.561.8187

Содержание i400s

Страница 1: ...se of qualified personnel only The i400s Calibration Information provides the information necessary to verify the performance and adjust the calibration of the Fluke i400s AC Current Clamp hereafter known as the Current Clamp The following information is included in this document Safety Information and Electrical Symbols Specifications Maintenance Performance Tests Calibration Adjustment User Repl...

Страница 2: ...an 1000 V CAT III or 600 V CAT IV CAT III equipment is designed to protect against transients in equipment in fixed equipment installations such as distribution panels feeders and short branch circuits and lighting systems in large buildings CAT IV equipment is designed to protect against transients from the primary supply level such as an electricity meter or an overhead or underground utility se...

Страница 3: ...23 5 C 20 to 75 RH conductor centered in jaw opening no DC component no adjacent conductor 40 A Range 400 A Range Measurement Range 0 5 A to 40 A 5 A to 400 A Output 10 mV A 1 mV A Accuracy 45 Hz to 400 Hz 2 0 015 A 2 0 04 A Phase Shift 45 Hz to 400 Hz 0 5 A to 1 A 1 A to 5 A 5 A to 10 A 10 A to 20 A 20 A to 40 A 40 A to 400 A Unspecified 4 3 3 2 NA NA NA Unspecified 2 2 1 5 Crest Factor 3 3 to 30...

Страница 4: ...WxH 150 x 70 x 30 mm 5 09 x 2 75 x 1 18 in Weight 114 g 4 oz Maintenance XW Warning To avoid possible electric shock or personal injury Before each use inspect the Current Clamp Look for cracks or missing portions of the clamp housing and output cable insulating cover and for loose or weakened components Pay particular attention to the insulation surrounding the clamp jaws Do not use a damaged Cur...

Страница 5: ...unction against the Clamp s specifications If the Current Clamp fails any part of the test calibration adjustment and or repair is indicated In the performance tests the Current Clamp is referred to as the unit under test UUT Required test equipment is defined in Table 2 Table 2 Required Test Equipment Equipment Required Characteristics Recommended Model Calibrator AC Current 0 8 A Max Accuracy 0 ...

Страница 6: ...00 Hz 0 4 A 400 Hz 19 56 20 44 1 mV A 400 A 50 Hz 8 0 A 50 Hz 391 96 408 04 1 mV A 400 A 100 Hz 8 0 A 100 Hz 391 96 408 04 10 mV A 2 A 50 Hz 40 mA 50 Hz 19 45 20 55 10 mV A 2 A 400 Hz 40 mA 400 Hz 19 45 20 55 10 mV A 40 A 50 Hz 0 8 A 50 Hz 391 85 408 15 10 mV A 40 A 100 Hz 0 8 A 100 Hz 391 85 408 15 bbc01f eps Figure 2 Current Accuracy Test Connections www com information itm com 1 800 561 8187 ...

Страница 7: ...t point VR1 3 Using a small flat head screwdriver adjust VR1 for a meter reading of 99 9 mV to 100 1 mV VR1 bbc02f eps Figure 3 i400s Calibration Point User Replaceable Parts The Current Clamp contains no user replaceable parts The following user documentation is available for this product Description Part No Qty i400s Instruction Sheet 2282671 1 i400s Calibration Information this document 2414327...

Страница 8: ...the warranty period To obtain warranty service contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB Destination Fluke assumes no risk for damage in transit Following warranty repair the product will be returned to Buyer transportation prepai...