background image

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Each Fluke product is warranted to be free from defects in material and 

workmanship under normal use and service. The warranty period is three 

years and begins on the date of shipment. Parts, product repairs, and 

services are warranted for 90 days. This warranty extends only to the 

original buyer or end-user customer of a Fluke authorized reseller, and does 

not apply to fuses, disposable batteries, or to any product which, in Fluke's 

opinion, has been misused, altered, neglected, contaminated, or damaged 

by accident or abnormal conditions of operation or handling. Fluke warrants 

that software will operate substantially in accordance with its functional 

specifications for 90 days and that it has been properly recorded on 

nondefective media. Fluke does not warrant that software will be error free or 

operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused 

products to end-user customers only but have no authority to extend a 

greater or different warranty on behalf of Fluke. Warranty support is available 

only if product is purchased through a Fluke authorized sales outlet or 

Buyer has paid the applicable international price. Fluke reserves the right to 

invoice Buyer for importation costs of repair/replacement parts when product 

purchased in one country is submitted for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase 

price, free of charge repair, or replacement of a defective product which is 

returned to a Fluke authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service 

center to obtain return authorization information, then send the product to 

that service center, with a description of the difficulty, postage and insurance 

prepaid (FOB Destination). Fluke assumes no risk for damage in transit. 

Following warranty repair, the product will be returned to Buyer, transportation 

prepaid (FOB Destination). If Fluke determines that failure was caused by 

neglect, misuse, contamination, alteration, accident, or abnormal condition of 

operation or handling, including overvoltage failures caused by use outside the 

product’s specified rating, or normal wear and tear of mechanical components, 

Fluke will provide an estimate of repair costs and obtain authorization before 

commencing the work. Following repair, the product will be returned to the 

Buyer transportation prepaid and the Buyer will be billed for the repair and 

return transportation charges (FOB Shipping Point).

THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND 

IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, 

INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE 

SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR 

CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, 

ARISING FROM ANY CAUSE OR THEORY.

Since some countries or states do not allow limitation of the term of an 

implied warranty, or exclusion or limitation of incidental or consequential 

damages, the limitations and exclusions of this warranty may not apply to 

every buyer. If any provision of this Warranty is held invalid or unenforceable 

by a court or other decision-maker of competent jurisdiction, such holding will 

not affect the validity or enforceability of any other provision.

 

Fluke Corporation 

Fluke Europe B.V

 

P.O. Box 9090 

PO Box 1186

 

Everett, WA 98206 

5602 BD EINDHOVEN

 

U.S.A. 

The Netherlands

11/99

Содержание FEV300

Страница 1: ...cle Charging Station Test Adapter Users Manual PN 5361878 May 2022 2022 Fluke Corporation All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies ...

Страница 2: ... Category II is applicable to test and measuring circuits connected directly to utilization points socket outlets and similar points of the low voltage MAINS installation PE PE Protective Earth CP CP Control Pilot Vehicles not requiring ventilation for indoor charging areas Vehicles requiring ventilation for indoor charging areas This product complies with the WEEE Directive and its marking requir...

Страница 3: ...f a Product probe or accessory Comply with local and national safety codes Use personal protective equipment approved rubber gloves face protection and flame resistant clothes to prevent shock and arc blast injury where hazardous live conductors are exposed Do not operate the Product with covers removed or the case open Hazardous voltage exposure is possible Do not use a current measurement as an ...

Страница 4: ...PE terminal by mistake touch electrode and LED Phase indicator presence of all three phase voltages measured to N three LED s PP State simulation open 13 A 20 A 32 A 63 A rotary switch CP State simulation state A B C D rotary switch CP Error state E simulation CP signal short circuited to PE push button PE Error state F Earth Fault simulation interruption of PE conductor push button Measurements o...

Страница 5: ...test purposes only Do not supply any appliance or charge an electric vehicle via these connectors In case of wrong wiring or error of the charging station terminals N and PE may present a hazard Operation Elements and Connectors Figure 2 Front panel function 1 2 3 4 5 6 7 8 9 11 10 12 13 1 PP Proximity Pilot State rotary switch selector open 13A 20A 32A and 63A 2 PE Pre Test warning indicator 3 PE...

Страница 6: ...of tests are done or if testing is done in an incorrect sequence then a potentially hazardous situation can occur for both the operator and the DUT Device Under Test The operator must fully understand the various tests required and how they should be done The charging station must pass the Protective Earth Ground PE Pre Test prior to the operator touching exposed metal surfaces or any other test I...

Страница 7: ...al standards which are linked to IEC HD 60364 6 for initial test or IEC HD 60364 7 722 Required tests are Visual inspection Continuity of protective conductors and protective bonding earth bond PE Insulation resistances Loop line impedance RCD trip test Function tests including but not limited to Vehicle state A B C D Error handling error state E PE Error state F Earth Fault Communication PWM sign...

Страница 8: ... 2 Connect above assembly to the charging station to be tested Proper test adapter connection to the charging station is shown in Figures 6 7 and 8 FEV300 CON TY2 FEV300 Charging Station Type 2 with panel mount socket outlet Figure 6 Test adapter to Type 2 with panel FEV300 CON TY2 FEV300 Charging Station Type 2 with fixed cable Figure 7 Test adapter to Type 2 with fixed cable FEV300 FEV300 CON TY...

Страница 9: ... shoes or other clothing Do not touch any metal parts of the charging station while performing this test In case of improper connection to earth for example isolated placement of your body this indication may be not reliable Test procedure 1 Connect the test adapter to the charging station 2 Touch the touch sensor with a bare finger If PE warning indicator item 2 Figure 2 illuminates then dangerou...

Страница 10: ... 63 A 100 Ω Control Pilot CP State Vehicle Simulation Use the CP State rotary switch selector item 10 Figure 2 to simulate various vehicle states when the test adapter is connected to the charging station Vehicle states are simulated with different resistances connected between CP and PE conductors Correlation between resistance and vehicle states is shown in Table 3 Table 3 Correlation between re...

Страница 11: ...nd the documentation of the manufacturer of the charging station CP output terminals are connected to CP and PE conductors of the charging station under test via the test cable The green socket is connected to PE These outputs are for connection of a meter with a duty cycle function or an oscilloscope to check the waveform and amplitude of the CP signal Verification of the maximum charging current...

Страница 12: ... 17 4 60 36 0 90 65 0 30 18 0 61 36 6 91 67 5 31 18 6 62 37 2 92 70 0 32 19 2 63 37 8 93 72 5 33 19 8 64 38 4 94 75 0 34 20 4 65 39 0 95 77 5 35 21 0 66 39 6 96 80 0 36 21 6 67 40 2 97 80 0 37 22 2 68 40 8 38 22 8 69 41 4 Error states Duty Cycle 0 Duty Cycle 3 State F or E see IEC EN 61851 1 Standard no charging allowed Duty Cycle 5 4 5 Duty Cycle 5 5 Indicates that digital communication is needed...

Страница 13: ...tion via the test cable Use these terminals for measuring purposes only Do not draw current over a longer period or supply anything else The terminals can be used to perform measurements like earth bond insulation loop line impedance RCD trip test voltage and Power Quality An appropriate measurement instrument for example the FLUKE 166x series is needed Maintenance When using the test adapter in c...

Страница 14: ...ection IEC 60529 IP54 housing IEC 60529 IP54 Measuring terminals with protection caps in place connector plug in connected condition or with protection caps in place otherwise IP20 Operating temperature 20 C to 40 C 4 F to 104 F Storage temperature 20 C to 50 C 4 F to 122 F Operating humidity range 10 to 85 relative humidity non condensing Storage relative humidity 0 to 85 non condensing Operating...

Страница 15: ...your nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB Destination Fluke assumes no risk for damage in transit Following warranty repair the product will be returned to Buyer transportation prepaid FOB Destination If Fluke determines that failure was ...

Отзывы: