![Fluke CableAnalyzer DSP-4100 Скачать руководство пользователя страница 188](http://html1.mh-extra.com/html/fluke/cableanalyzer-dsp-4100/cableanalyzer-dsp-4100_user-manual_2309836188.webp)
DSP-4000 Series
Users Manual
8-18
HDTDX
Analyzer Specifications for Cables <100 m (328 ft)
The following performance is typical for cables less than 100 m (328 ft):
Distance accuracy: ±(1 ft (0.3 m) + 2 % distance)
Distance resolution: 1 ft or 0.1 m
HDTDR
Specifications for Cables <100 m (328 ft)
The specifications below are for HDTDR tests on cables less than 100 m (328 ft)
long.
Twisted Pair Cable
Coaxial Cable
Distance accuracy
±
(1 ft (0.3 m) + 2 % distance)
±
(1 ft (0.3 m) + 2 % distance)
Distance resolution
1 ft or 0.1 m
1 ft or 0.1 m
Impulse Noise
Adjustable from 10 mV to 500 mV in 10 mV steps. The default threshold is
270 mV.
Monitors either polarity of noise on pair 3, 6.
Minimum detectable impulse width: 10 ns
Characteristic Impedance
The test tool reports an estimate of the cable's impedance at 4 m from the
beginning of the link. The accuracy of the measurement is relative to a 100
Ω
terminating resistance.
Twisted Pair Cable
Coaxial Cable
Range
70
Ω
- 180
Ω
35
Ω
- 100
Ω
Accuracy
± (5
Ω
+ 5 %
Nominal - Measured
)
± (5
Ω
+ 5 %
Nominal - Measured
)
Anomaly Threshold
15 % Reflection
10 % Reflection
Resolution
1
Ω
1
Ω
Содержание CableAnalyzer DSP-4100
Страница 10: ...DSP 4000 Series Users Manual viii...
Страница 20: ...DSP 4000 Series Users Manual 1 8...
Страница 66: ...DSP 4000 Series Users Manual 2 46...
Страница 99: ...Autotest The Autotest Report 3 3 33 oy82f bmp Figure 3 12 Autotest Report in Tabular Format...
Страница 138: ...DSP 4000 Series Users Manual 6 6...
Страница 170: ...DSP 4000 Series Users Manual 7 32...
Страница 195: ...Appendices Appendix Title Page A Tests Supported by LIAs A 1 B Glossary B 1...
Страница 196: ......
Страница 210: ...DSP 4000 Series Users Manual B 12...
Страница 216: ...DSP 4000 Series Users Manual 6...