![Fluke CableAnalyzer DSP-4100 Скачать руководство пользователя страница 182](http://html1.mh-extra.com/html/fluke/cableanalyzer-dsp-4100/cableanalyzer-dsp-4100_user-manual_2309836182.webp)
DSP-4000 Series
Users Manual
8-12
Length
Twisted Pair Cable
Coaxial Cable
Range
0 ft to 328 ft
(0 m - 100 m)
328 ft to 2500 ft
(100 m - 762 m)
0 ft to 328 ft
(0 -100 m)
328 ft to 4000 ft
(100 m - 1219 m)
Resolution
1 ft or 0.1 m
1 ft or 0.1 m
1 ft or 0.1 m
1 ft or 0.1 m
Accuracy
± (1 ft (0.3 m)
+ 2 % of reading)
± (1 ft (0.3 m)
+ 4 % of reading)
± (1 ft (0.3 m)
+ 2 % of reading)
± (1 ft (0.3 m)
+ 4 % of reading)
Note
Specifications are relative to calibrated value using a representative
reference cable. Variations occur because of variations in the cable
manufacturing process.
Propagation Delay
Twisted Pair Cable
Coaxial Cable
Range
0 ns to 500 ns
500 ns to 3800 ns
0 ns to 500 ns
500 ns to 6000 ns
Resolution
1 ns
1 ns
1 ns
1 ns
Accuracy
±
(5 ns + 2 % of
reading)
±
(5 ns + 4 % of
reading)
±
(5 ns + 2 % of
reading)
±
(5 ns + 4 % of
reading)
Delay Skew
Twisted Pair Cable
Range
0 ns to 100 ns
Resolution
1 ns
Accuracy
±
10 ns
DC Loop Resistance Test
Range: 0
Ω
to 400
Ω
Accuracy: ±(2
Ω
+ 2 % of reading)
Resolution: 0.1
Ω
Overload recovery time: Less than 10 minutes to rated accuracy following an
overvoltage. Self-calibration is required after repeated or prolonged overvoltage.
Содержание CableAnalyzer DSP-4100
Страница 10: ...DSP 4000 Series Users Manual viii...
Страница 20: ...DSP 4000 Series Users Manual 1 8...
Страница 66: ...DSP 4000 Series Users Manual 2 46...
Страница 99: ...Autotest The Autotest Report 3 3 33 oy82f bmp Figure 3 12 Autotest Report in Tabular Format...
Страница 138: ...DSP 4000 Series Users Manual 6 6...
Страница 170: ...DSP 4000 Series Users Manual 7 32...
Страница 195: ...Appendices Appendix Title Page A Tests Supported by LIAs A 1 B Glossary B 1...
Страница 196: ......
Страница 210: ...DSP 4000 Series Users Manual B 12...
Страница 216: ...DSP 4000 Series Users Manual 6...