![Fluke CableAnalyzer DSP-4000 Series Скачать руководство пользователя страница 90](http://html1.mh-extra.com/html/fluke/cableanalyzer-dsp-4000-series/cableanalyzer-dsp-4000-series_user-manual_2309835090.webp)
DSP-4000 Series
Users Manual
3-30
The Autotest Report
With CableManager software you can upload reports to a PC for viewing and
printing. The CableManager appendix in this manual shows examples of complete
Autotest reports for twisted pair cable.
You can send Autotest reports directly to a serial printer or edit the report’s
identification information in the PRINT mode. See Chapter 5, “Viewing and
Printing Saved Reports,” for complete instructions.
The overall result printed on a report can be a pass or fail, or warning. A failure of
any test required by the selected test standard produces a fail result on the report
summary. If required by the selected standard, a warning appears on reports for
twisted pair cable if a length, impedance, propagation delay, or delay skew test
produced a warning. The warning means that the measurement exceeds its limit,
but the test standard does not fail the cable based on that measurement.
Содержание CableAnalyzer DSP-4000 Series
Страница 6: ...DSP 4000 Series Users Manual iv...
Страница 8: ...DSP 4000 Series Users Manual vi...
Страница 18: ...DSP 4000 Series Users Manual 1 8...
Страница 60: ...DSP 4000 Series Users Manual 2 42...
Страница 128: ...DSP 4000 Series Users Manual 6 6...
Страница 160: ...DSP 4000 Series Users Manual 7 32...
Страница 186: ...DSP 4000 Series Users Manual 8 26...
Страница 188: ...DSP 4000 Series Users Manual...
Страница 204: ...DSP 4000 Series Users Manual B 14 oy81f bmp Figure B 5 Autotest Report in Graphical Format...
Страница 210: ...DSP 4000 Series Users Manual B 20...
Страница 222: ...DSP 4000 Series Users Manual C 12...