Specifications
Size:
4.2 x 6.6 x 1.3 in. (11x17x3.3 cm)
Weight:
12.8 oz. (364 g)
Operating Temperature:
-4
o
F to +140
o
F (-
20
ο
C to +60
o
C)
Storage Temperature:
-40
o
F to +158
o
F (-40
o
C to +70
o
C)
DC Input Voltage:
+6 to +15 VDC
DC Input Current (Standby Mode):
210 mA@ 8VDC (Typ.)
DC Input Current (Active Mode):
420 mA @ 8VDC (Typ.)
990 Battery Operating Time (Active Mode)
4 Hours Continuous (Typ.)
ADSL Standards Compliance (ATU-R):
ADSL ANSI
ADSL G.DMT
ADSL G.Lite
ADSL2
ADSL2+
ANSI T1.413 Issue 2
ITU G.992.1a, b
ITU G.992.2ab
ITU G.992.3a, b, l, m
ITU G.992.5a, b
Regulatory Compliance:
CSA: C22.2 No 1010.1
CE: EN 61326 Class A
CE: EN61010-1
DSL Connector Pinout:
Pin 3, 4
Pins 1, 2, 5, 6
DSL Tip, Ring
Not Used
ENET Connector Pinout:
Pin 1, 2
Pin 3, 4
Pins 4, 5, 7, 8
Ethernet Rx+, Rx-
Ethernet Tx+, Tx-
Not Used
990 Software Version Required:
3.21.16 (or greater)
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Fluke Networks mainframe products will be free from defects in material and workmanship for
one year from the date of purchase. Parts, accessories, product repairs and services are
warranted for 90 days, unless otherwise stated. Ni-Cad, Ni-MH and Li-Ion batteries, cables or
other peripherals are all considered parts or accessories. This warranty does not cover damage
from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation
or handling. Resellers are not authorized to extend any other warranty on Fluke Networks’
behalf. To obtain service during the warranty period, contact your nearest Fluke Networks
authorized service center to obtain return authorization information, then send your defective
product to that Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A
PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE NETWORKS IS NOT LIABLE FOR
ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING
FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or
limitation of an implied warranty or of incidental or consequential damages, this limitation of
liability may not apply to you.
Fluke Networks
PO Box 777
Everett, WA 98206-0777
USA