Introduction and Specifications
Electrical Specifications
1
1-19
8845A Accuracy
Accuracy is given as
±
(% measu % of range)
Range
Frequency
(Hz)
24 Hour
(23
±
1
°
C)
90 Days
(23
±
5
°
C)
1 Year
(23
±
5
°
C)
Temperature
Coefficient/
°
C
Outside 18 to 28
°
C
3 – 5 Hz
1.1 + 0.06
1.1 + 0.06
1.1 + 0.06
0.2 + 0.006
5 – 10 Hz
0.35 + 0.06
0.35 + 0.06
0.35 + 0.06
0.1 + 0.006
10 Hz – 5 kHz
0.15 + 0.06
0.15 + 0.06
0.15+ 0.06
0.015 + 0.006
10 mA
5 – 10 kHz
0.35 + 0.7
0.35 + 0.7
0.35 + 0.7
0.03 + 0.006
3 – 5 Hz
1.0 + 0.04
1.0 + 0.04
1.0 + 0.04
0.1 + 0.006
5 – 10 Hz
0.3 + 0.04
0.3 + 0.04
0.3 + 0.04
0.035 + 0.006
10 Hz – 5 kHz
0.1 + 0.04
0.1 + 0.04
0.1 + 0.04
0.015 + 0.006
100 mA
5 – 10 kHz
0.2 + 0.25
0.2 + 0.25
0.2 + 0.25
0.03 + 0.006
3 – 5 Hz
1.0 + 0.1
1.0 + 0.1
1.0 + 0.1
0.1 + 0.006
5 – 10 Hz
0.3 + 0.1
0.3 + 0.1
0.3 + 0.1
0.035 + 0.006
10 Hz – 1 kHz
0.1 + 0.1
0.1 + 0.1
0.1 + 0.1
0.015 + 0.006
400 mA
[3]
1kHz – 10 kHz
0.2 + 0.7
0.2 + 0.7
0.2 + 0.7
0.03 + 0.006
3 – 5 Hz
1.0 + 0.04
1.0 + 0.04
1.0 + 0.04
0.1 + 0.006
5 – 10 Hz
0.3 + 0.04
0.3 + 0.04
0.3 + 0.04
0.035 + 0.006
10 Hz – 5 kHz
0.1 + 0.04
0.1 + 0.04
0.1 + 0.04
0.015 + 0.006
1 A
[2]
5 – 10 kHz
0.35 + 0.7
0.35 + 0.7
0.35 + 0.7
0.03 + 0.006
3 – 5 Hz
1.1 + 0.06
1.1 + 0.06
1.1 + 0.06
0.1 + 0.006
5 – 10 Hz
0.35 + 0.06
0.35 + 0.06
0.35 + 0.06
0.035 + 0.006
10 Hz – 5 kHz
0.15 + 0.06
0.15 + 0.06
0.15 + 0.06
0.015 + 0.006
3 A
[1][2]
5 – 10 kHz
0.35 + 0.7
0.35 + 0.7
0.35 + 0.7
0.03 + 0.006
3 – 5 Hz
1.1 + 0.06
1.1 + 0.06
1.1 + 0.06
0.2 + 0.006
5 – 10 Hz
0.35 + 0.06
0.35 + 0.06
0.35 + 0.06
0.035 + 0.006
10 Hz – 5 kHz
0.15 + 0.06
0.15 + 0.06
0.15 + 0.06
0.015 + 0.006
10 A
[2]
5 – 10 kHz
0.35 + 0.7
0.35 + 0.7
0.35 + 0.7
0.03 + 0.006
[1] Part of the 10 A range
[2] Available only at front panel connectors
[3] 400 mA available in software version 1.0.700.18 or greater only. 400 mA continuously; 550 mA for 2 minutes on,
1 minute off; maximum crest factor 3:1 at 400 mA; specification for current above 329 mA is typical.
Additional Low Frequency Errors
Error is stated as % of reading.
AC Filter
Frequency
3HZ (slow)
20HZ (medium)
200HZ (fast)
10 – 20 Hz
0
0.25
–
20 – 40 Hz
0
0.02
–
40 – 100 Hz
0
0.01
0.55
100 – 200 Hz
0
0
0.2
200 Hz – 1 kHz
0
0
0.02
> 1 kHz
0
0
0
Frequency
Gate Times ............................................................. Programmable to 1 s, 100 ms, and 10 ms
Measurement Method ............................................. Flexible counting technique. AC-coupled input using the ac voltage
measurement function.
Settling Considerations ........................................... When measuring frequency or period after a dc offset voltage change,
errors may occur. For the most accurate measurement, wait up to
1 second for the input blocking capacitor to settle.
Measurement Considerations ................................. To minimize measurement errors, shield inputs from external noise
when measuring low-voltage, low-frequency signals.
Содержание 8845A
Страница 6: ...8845A 8846A Users Manual iv...
Страница 8: ...8845A 8846A Users Manual vi...
Страница 10: ...8845A 8846A Users Manual viii...
Страница 12: ...8845A 8846A Users Manual 1 2 Diode Test 1 22 Measurement Rates IEEE488 4 1 22...
Страница 34: ...8845A 8846A Users Manual 2 2...
Страница 42: ...8845A 8846A Users Manual 2 10...
Страница 70: ...8845A 8846A Users Manual 4 2...
Страница 88: ...8845A 8846A Users Manual...
Страница 90: ...8845A 8846A Users Manual A 2...
Страница 96: ...8845A 8846A Users Manual C 2...
Страница 101: ...Index continued 3 U Unpacking Meter 2 3 User documentation 1 3 V Voltage AC measurements 4 5 DC measurements 4 4...
Страница 102: ...8845A 8846A Users Manual 4...