Pressure Calibrator 

 

Specifications 

 

1-year Specifications 

Low Pressure Sensor 

High Pressure Sensor 

Model 

Calibrator 

Description 

Range 

Sensor 1 

Resolution 

Sensor 1 

Accuracy 

Sensor 1 

Range Sensor 2 

Resolution 

Sensor 2 

Accuracy 

Sensor 2 

721-1601 

16 PSIG, 100 PSIG 

-14 psi + 16 psi
-0.97 bar to 
1.1 bar 

0.001 psi, 
0.0001 bar 

0.025 % of 
full scale  

-12 psi to +100 psi 
-0.83 bar to 6.9 bar 

0.001 psi 
0.0001 bar 

0.025 % of 
full scale 

721-1603 

16 PSIG, 300 PSIG 

-12 psi to +300 psi 
-0.83 bar to 20 bar 

0.01 psi 
0.001 bar 

721-1605 

16 PSIG, 500 PSIG 

-12 psi to +500 psi 
-0.83 bar to 34.5 bar 

0.01 psi 
0.001 bar 

721-1610 

16 PSIG, 1000 
PSIG 

0 psi to +1000 psi 
0.00 bar to 69 bar 

0.01 psi 
0.001 bar 

721-1615 

16 PSIG, 1500 
PSIG 

0 psi to +1500 psi 
0.00 bar to 103.4 bar 

0.1 psi 
0.01 bar 

721-1630 

16 PSIG, 3000 
PSIG 

0 psi to +3000 psi 
0.00 bar to 200 bar 

0.1 psi 
0.01 bar 

721-1650 

16 PSIG, 5000 
PSIG 

0 psi to +5000 psi 
0.00 bar to 345 bar 

0.1 psi 
0.01 bar 

0.035 % of 
full scale 

721-3601 

36 PSIG, 100 PSIG 

-14 psi + 36 psi
-0.97 bar to 
2.48 bar 

-12 psi to +100 psi 
-0.83 bar to 6.9 bar 

0.001 psi 
0.0001 bar 

0.025 % of 
full scale 
  

721-3603 

36 PSIG, 300 PSIG 

-12 psi to +300 psi 
-0.83 bar to 20 bar 

0.01 psi 
0.001 bar 

721-3605 

36 PSIG, 500 PSIG 

-12 psi to +500 psi 
-0.83 bar to 34.5 bar 

0.01 psi 
0.001 bar 

721-3610 

36 PSIG, 1000 
PSIG 

0 psi to +1000 psi 
0.00 bar to 69 bar 

0.01 psi 
0.001 bar 

721-3615 

36 PSIG, 1500 
PSIG 

0 psi to +1500 psi 
0.00 bar to 103.4 bar 

0.1 psi 
0.01 bar 

721-3630 

36 PSIG, 3000 
PSIG 

0 psi to +3000 psi 
0.00 bar to 200 bar 

0.1 psi 
0.01 bar 

721-3650 

36 PSIG, 5000 
PSIG 

0 psi to +5000 psi 
0.00 bar to 345 bar 

0.1 psi 
0.01 bar 

0.035 % of 
full scale 

 

Electromagnetic Environment ....................... IEC 61326-1: Portable 

Electromagnetic Compatibility....................... Applies to use in Korea only. Class A Equipment (Industrial Broadcasting & 

Communication Equipment) 

[1]

 

[1]  This product meets requirements for industrial (Class A) electromagnetic 
wave equipment and the seller or user should take notice of it. This 
equipment is intended for use in business environments and is not to be used 
in homes. 

Содержание 721-1601

Страница 1: ...2014 2014 Fluke Corporation All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies 721 Pressure Calibrator Calibration...

Страница 2: ...r nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB...

Страница 3: ...cation Tests 6 Pressure Verification 7 DC Voltage Measure Verification 9 DC Current Measure Verification 10 RTD Measure Verification 10 720RTD Probe Verification 11 mA Loop Performance Check 11 Calibr...

Страница 4: ...721 Calibration Manual ii...

Страница 5: ...fication and Calibration 6 3 Pressure Verification Tests 7 4 DC Voltage Measure Verification Tests 9 5 DC Current Measure Verification Tests 10 6 RTD Measure Verification Tests 10 7 720RTD Probe Verif...

Страница 6: ...721 Calibration Manual iv...

Страница 7: ...v List of Figures Figure Title Page 1 Battery Replacement 17 2 User Replaceable Parts 20...

Страница 8: ...721 Calibration Manual vi...

Страница 9: ...ion options that include absolute and differential pressure measurement Contact Fluke To contact Fluke call one of the following telephone numbers Technical Support USA 1 800 44 FLUKE 1 800 443 5853 C...

Страница 10: ...r 60 V dc Remove all probes test leads and accessories before the battery door is opened Do not exceed the Measurement Category CAT rating of the lowest rated individual component of a Product probe o...

Страница 11: ...or in this manual are shown in Table 1 Table 1 Symbols Symbol Description Symbol Description Risk of Danger Important information See Manual Conforms to relevant North American Safety Standards Hazar...

Страница 12: ...V dc Measure 0 to 30 V dc 0 001 V 0 015 of rdg 0 002 V Temperature measure RTD Ohms 40 C to 150 C 40 F to 302 F 0 01 C 0 01 F 0 015 of rdg 0 02 0 1 C 0 2 F 0 25 C 0 45 F combined uncertainty when usi...

Страница 13: ...1 psi 0 01 bar 0 035 of full scale 721 3601 36 PSIG 100 PSIG 14 psi 36 psi 0 97 bar to 2 48 bar 12 psi to 100 psi 0 83 bar to 6 9 bar 0 001 psi 0 0001 bar 0 025 of full scale 721 3603 36 PSIG 300 PSI...

Страница 14: ...0xi Piston Gauge 3000 PSI to 5000 PSI 0 005 Fluke Calibration PG7302 or PG7202 Metrology Well 30 C to 140 C 0 06 C Fluke Calibration 9170 Performance Verification Tests Warning To prevent possible ele...

Страница 15: ...pressure port 5 Connect and test the second pressure port 6 Set up the deadweight tester for the sequence of PSI inputs from Table 3 to be injected into the pressure port of the Product 7 Ensure the...

Страница 16: ...1000 PSI Input Pressure Lower Limit Upper Limit Input Pressure Lower Limit Upper Limit 500 00 499 87 500 13 1000 0 999 75 1000 25 400 00 399 87 400 13 800 0 799 75 800 25 300 00 299 87 300 13 600 0 5...

Страница 17: ...oltage measure verification test 1 Push repeatedly until VOLTS is shown on the third row of the Product display 2 Connect the Product red banana jack V mA to the Calibrator HI VOLTS output 3 Connect t...

Страница 18: ...4 mA 24 006 mA 5 Set the Calibrator to Standby RTD Measure Verification 1 Push repeatedly until RTD is shown in the third row of the Product display 2 Connect the RTD Adapter to the Product 3 Connect...

Страница 19: ...lerance Table 7 720RTD Probe Verification Tests Applied Temperature Lower Limit Upper Limit 30 00 C 30 25 C 29 75 C 0 00 C 0 25 C 0 25 C 70 00 C 69 75 C 70 25 C 130 00 C 129 75 C 130 25 C 5 Set the Me...

Страница 20: ...o the 5 pin Lemo on the side of the Product Connect the other end of the cable to the terminal PC serial port The terminal settings need to be set as follows Bits per second 9600 Data bits 8 Parity No...

Страница 21: ...put 30 V 6 When the reading is stable send this command CAL_POINT 0 1 7 The voltage range is now calibrated Adjust mA Input To adjust the mA input 1 Use the test lead set to attach the voltage output...

Страница 22: ...ense jacks of the RTD Adapter to the high side of the sense output of the Resistance Standard 5 Connect the low side of the sense jacks of the RTD Adapter sense input to the low side of the sense outp...

Страница 23: ...lue returned 4 Use the Pressure Standard to input a value equal or close to the noted value 5 When the pressure is stable send the OFFSET_ADJ n command where n is the entered pressure 6 Send the GAIN_...

Страница 24: ...amage the Product Replace the batteries when the low battery indicator shows to prevent incorrect measurements Be sure that the battery polarity is correct to prevent battery leakage Repair the Produc...

Страница 25: ...Pressure Calibrator Maintenance 17 hmq061 eps Figure 1 Battery Replacement...

Страница 26: ...ion Qty Part Number Case Top Assembly For 721 1 4409796 Fluke 721 Lens 721 1 4364743 Screw 5 20k 312 Ph Threaded 4 494641 Fluke 7xx Display Module 1 4404450 Fluke 721 Keypad 1 4364568 Conn Panel Mount...

Страница 27: ...00bar 1 4374301 Not Shown Fluke 721 Decal Rear Serial Number Plate 1 4364755 Not Shown Tie Cable 4 1 172080 See www fluke com for more information about the test leads and alligator clips available fo...

Страница 28: ...721 Calibration Manual 20 1 6 11 13 3 5 2 4 10 9 12 8 7 14 15 hmq101 eps Figure 2 User Replaceable Parts...

Отзывы: