![Fluke 5020A Скачать руководство пользователя страница 79](http://html1.mh-extra.com/html/fluke/5020a/5020a_user-manual_2309639079.webp)
Digital Communications Interface
Interface Commands
6
6-9
specified channel
DATa:RECord:FREE?
Returns the recording memory usage
DATa:RECord:OPEN?
Returns the number of bytes in the open data set
DATa:RECord:OPEN
(<year>,<month>,<day>,<hour>,<minute>,<second>[,
<year>,<month>,<day>,<hour>,<minute>,<second>)
Opens the range of data for reading
DATa:RECord:READ? [<num>]
Returns a group of data
DATa:RECord:TIMe?
Returns the data recording timer
DATa:RECord:TIMe <num>|MIN|MAX|DEF
Sets the data recording timer
FETCh? [<chn>]
Returns the temperature and humidity measurements
for the specified channel
FORMat:TDSTamp:STAT?
Returns the state of the date/time stamp for
FETCh,MEASure, or READ command
FORMat:TDSTamp:STAT? <bool>
Enables or disables the date/time stamp for FETCh,
MEASure, or READ command
INITiate no
action
INITiate:CONTinous?
Returns the continuous state (always 1)
MEASure? [<chn>]
Returns the temperature and humidity measurements
for the specified channel
READ? [<chn>]
Returns the temperature and humidity measurements
for the specified channel
ROUTe:CLOSe? [<chn>]
Returns the state of the specified channel
ROUTe:CLOSe <chn>
Enables the specified channel
ROUTe:OPEN? [<chn>]
Returns the channel state
ROUTe:OPEN <chn>
Disables the specified channel
SENSor:AVERage?
Returns the state of the measurement averaging
SENSor:AVERage <bool>
Enables or disables the measurement averaging
SENSor<chn>:LOCK?
Returns the state of the sensor lock for the specified
channel
SENSor<chn>:LOCK <bool>
Enables or disables the sensor lock for the specified
channel
SENSor<chn>:IDENification?
Returns the sensor identification for the specified
channel
SENSor<chn>:IDENification <str>
Sets the sensor identification for the specified channel
SENSor<chn>:STATus?
Returns the sensor status for the specified channel
STATus:ALARm?
Returns and clears the alarm status event
STATus:ALARm:CONDition?
Returns the alarm status condition
STATus:ALARm:ENABle?
Returns the alarm status enable
Содержание 5020A
Страница 6: ...5020A Users Manual iv...
Страница 8: ...5020A Users Manual vi...
Страница 12: ...5020A Users Manual 1 2...
Страница 20: ...5020A Users Manual 2 2...
Страница 24: ...5020A Users Manual 3 2...
Страница 30: ...5020A Users Manual 3 8...
Страница 32: ...5020A Users Manual 4 2...
Страница 38: ...5020A Users Manual 5 2 Comm Setting 5 30 Serial 5 31 IR 5 32 Password 5 32 System Info 5 34...
Страница 72: ...5020A Users Manual 6 2...
Страница 124: ...5020A Users Manual 6 54...
Страница 126: ...5020A Users Manual 7 2...
Страница 130: ...5020A Users Manual 7 6...
Страница 132: ...5020A Users Manual 8 2...
Страница 138: ...5020A Users Manual 8 8...
Страница 141: ...Index continued 3 W warnings 1 4 Z zone types 5 9...
Страница 142: ...5020A Users Manual 4...