Fluke 438-II Скачать руководство пользователя страница 2

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The 

warranty period is three years and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 

days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not 

apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected, 

contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will 

operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on 

non-defective media. Fluke does not warrant that software will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no 

authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is 

purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the 

right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted 

for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or 

replacement of a defective product which is returned to a Fluke authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, 

then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB 

Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, 

transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination, 

alteration, accident, or abnormal condition of operation or handling, including overvoltage failures caused by use outside 

the product’s specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair 

costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer 

transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, 

EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR 

FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, 

INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY 

CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of 

incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any 

provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such 

holding will not affect the validity or enforceability of any other provision.

11/99

Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.

Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands

Содержание 438-II

Страница 1: ...March 2016 Rev 1 10 17 2016 2017 Fluke Corporation All rights reserved All product names are trademarks of their respective companies 438 II Motor Analyzer Users Manual...

Страница 2: ...r nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB...

Страница 3: ...Motor Measurements 3 Motor Setup 4 Unit Setup 6 Set Analyzer Limits 7 Trend Setup 7 Motor Analyzer Parameters 8 Mechanical Parameters 8 Electrical Parameters 9 View Analyzer Limit 9 Meter Screen 10 Tr...

Страница 4: ...ii 438 II Users Manual...

Страница 5: ...eed to use additional mechanical sensors or shut down the process The Motor Analyzer is for three wire three phase DELTA measurement configurations If any other configuration is active the feature pro...

Страница 6: ...oduct if it is damaged Disable the Product if it is damaged Do not work alone See the 434 II 435 II 437 II Users Manual for a complete list of Safety Warnings and explanation of Symbols used on the Pr...

Страница 7: ...to 100 0 1 3 1 NA Unbalance NEMA MG 1 0 to 100 0 1 0 15 5 Harmonics Voltage Factor NEMA MG 1 0 to 0 20 0 01 1 5 0 15 Unbalance Derating Factor 0 7 to 1 0 0 1 indicative NA Harmonics Derating Factor 0...

Страница 8: ...drives 5 Use to enter the motor nameplate parameters The Motor Analyzer supports motor designs according to NEMA and IEC design types See Table 5 and Table 6 If the design type is unknown select Othe...

Страница 9: ...ine VSD 300 rpm to 3600 rpm 800 rpm to 3600 rpm 1 rpm Rated Voltage 50 Hz motors 60 Hz motors 170 V to 1000 V 208 V to 1000 V 1 V Rated Current 1 A to 1500 A 0 1 A Rated Frequency 50 Hz or 60 Hz Rated...

Страница 10: ...7 Supported Variable Speed Drives Drive Characteristics Supported Range Drive Output Frequency 41 Hz to 69 Hz Drive Type Voltage Source Inverter only Drive Control Method V f Volt over Hertz only open...

Страница 11: ...Trend Setup screen is a simplified version of the normal TIMED START screen Motor Analyzer has an immediate start mode only and TIMED START is not available To open the screen go to Motor Setup screen...

Страница 12: ...wer supplied and mechanical power delivered in A colored bar graph indicates the performance of the motor compared to its rating The actual value for each parameter shows in the appropriate unit its r...

Страница 13: ...s View Analyzer Limit The View Analyzer Limit screen has the same information as the Set Analyzer Limits screen but is read only The only allowed action is OK or BACK to go to the Motor Analyzer scree...

Страница 14: ...ge 6 Speed rpm Efficiency Frequency Hz Harmonics HVF NEMA no unit Unbalance NEMA Harmonics Derating Factor HDF no unit Unbalance Derating Factor UDF no unit Total Derating Factor no unit The other par...

Страница 15: ...the 43X Series II that shows the recorded measurement data over time Note The Power Quality EVENT capture function is not available in Motor Analyzer to scroll through the METER screen Opens the ANAL...

Страница 16: ...alanced currents in the stator windings will result A small percentage of voltage unbalance will result in a much larger percentage of current unbalance Consequently the temperature rise of the motor...

Страница 17: ...ied When a voltage is applied to the motor that consists of components at frequencies other than the fundamental frequency the rated power of the motor should be derated according to the Derating Fact...

Страница 18: ...on the motor and entered in the Motor Setup screen The red area indicates the overload area for the motor A persistence function that plots the cross hair center in blue color is automatically enabled...