5

Measuring

Fluke 416D

GB

D

F

I

E

P

NL

DK

NO

S

FIN

GR

TR

CZ

SK

PL

HU

RU

RO

CN

KOR

the stop bracket with a little force to the right 
side; the stop bracket can now be completely 
unfolded. See drawing {

E

}.

CAUTION:

Make sure that when measuring from the 

unfolded endpiece, the measuring reference point is 
set to "End piece".

1x briefly: the next measurement is taken from 
the front edge.

2x briefly: the measurement is taken from the 
unfolded end piece.

After one measurement, the reference point returns 
automatically to the default setting (rear reference 
point).

1x long: the measurements are taken with the 
front as reference until a new measuring refer-
ence point is set.

2x long: the measurements are taken from the 
unfolded end piece until a new measuring refer-
ence point is set.

See drawing {

F

}.

Measuring

Single Distance Measurement

1x briefly: the laser is activated.

1x briefly: a distance measurement is taken. 

The result is displayed immediately.

Continuous measurement

Distances can be measured with this function.

1x long: a "beep" is emitted. A continuous 
measurement is started.

1x briefly: the continuous measurement is 
stopped. 

The last measured value is displayed in the primary 
display.

Minimum-/Maximum-Measuring

This function enables determining the minimum or 
maximum distance from a specific measuring point, 
e.g. the determination of room diagonals (maximum 
value) or horizontal distance (minimum value).
Switching on continuous measurement (see above). 
The corresponding maximum and minimum values are 
displayed.

Содержание 416D

Страница 1: ...16D Laser Distance Meter Users Manual July 2008 2008 Fluke Corporation All rights reserved Specifications subject to change without notice All product names are trademarks of their respective companie...

Страница 2: ...e center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB Destination Fluke assumes no ris...

Страница 3: ...nically correct and efficient manner Intended Use Permitted uses Measuring distances Computing functions e g areas and volumes Adverse uses Using the instrument without instructions Using outside the...

Страница 4: ...ation with the Fluke equipment Responsibilities of the person in charge of the instrument WARNING The person responsible for the instrument must ensure that the equipment is used in accord ance with t...

Страница 5: ...g time remove the batteries as a protection against corrosion Operation Measuring Conditions Range Range is limited to 60 m 200 ft At night or dusk and if the target is in shadow the measuring range w...

Страница 6: ...cur Switching on off 1x briefly the instrument and the laser are switched on The display shows the battery symbol until the next button is pressed Pressing this button for longer switches the instrume...

Страница 7: ...oint is set 2x long the measurements are taken from the unfolded end piece until a new measuring refer ence point is set See drawing F Measuring Single Distance Measurement 1x briefly the laser is act...

Страница 8: ...in the primary display the individually measured values are displayed in secondary display lines 1 and 2 Adding and subtracting areas Calling up the area function and measuring areas Press once twice...

Страница 9: ...Indirect measurement determining a distance using 2 auxilliary measurements See drawing G 1x briefly the symbol is displayed The distance to be measured flashes in the symbol 1x briefly takes a measu...

Страница 10: ...hold simultaneously for 5 seconds The beep is switched off To reactivate it press and hold for 5 seconds Appendix Display Notices All display notices are either displayed with or Error The following e...

Страница 11: ...on and electrostatic discharges are present and without causing electromagnetic interference to other equipment WARNING The Fluke 416D conforms to the most stringent requirements of the relevant stand...

Страница 12: ...the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help W...

Страница 13: ...lutions Disposal Do not dispose of this product as unsorted municipal waste Go to Fluke s website for recycling information All rights reserved for changes drawings descrip tions and technical specifi...

Страница 14: ......

Страница 15: ...1 2 3...

Страница 16: ......

Отзывы: