Memory
1x briefly: the
symbol and the last measured
value are displayed.
Use the
or
buttons to navigate through the
last 10 values. The values can also be used in func-
tions.
Using stored values in functions
Using added distances in area functions (e.g. wall
surfaces):
Adding distances (see additions / subtractions)
Call up area function to e.g. measure the height
of a room.
1x briefly: calls up memory and to search for the
correct value.
1x long: the value is entered into the function
and the result of the function (e.g. area) is
displayed.
Switching off the beep
Press and hold simultaneously for 5
seconds:
The beep is switched off.
To reactivate it, press and hold for 5 seconds.
Appendix
Display Notices
All display notices are either displayed with
or
"Error". The following errors can be corrected.
Cause
Correction
204
Calculation error
Repeat procedure
252
Temperature too
high
Let device cool down
253
Temperature too
low
Warm device up
255
Received signal too
weak, time for a
measurement too
long
Use a target plate
256
Received signal too
strong
Use target plate (gray
side)
257
Faulty measure-
ment, too much
background light
Use target plate (brown
side)
258
Outside of the
measurement range
Select measurement
distance within the
range of measurement
Error
Cause
Correction
Error
Hardware error
Should this message
remain active after
switching the instru-
ment off and on several
times, please contact
the dealership