3
Start up
Fluke 416D
GB
D
F
I
E
P
NL
DK
NO
S
FIN
GR
TR
CZ
SK
PL
HU
RU
RO
CN
KOR
Display
See drawing {
B
}
1
Laser "ON"
2
Reference point (front/rear/end piece)
3
Indirect measurement
4
Memory
5
Area/volume
6
Battery status
7
Units with exponents (
2
/
3
)
8
Secondary display line 2
9
Secondary display line 1
10 Primary display
11 Min / max display
12 Info symbol
Start up
Inserting / Replacing Batteries
1
Remove battery compartment lid.
See drawing {
C
}.
2
Insert batteries, observing correct polarity.
3
Close the battery compartment.
•
Replace the batteries when the symbol
flashes
permanently in the display.
Note:
Only use alkaline batteries.
Note:
If the instrument will not be used for a long
time, remove the batteries as a protection against
corrosion.
Operation
Measuring Conditions
Range
Range is limited to 60 m (200 ft).
At night or dusk and if the target is in shadow the
measuring range without the target plate is
increased. Use a target plate to increase the meas-
urement range during daylight, or if the target has
poor reflection properties!
Target Surfaces
CAUTION:
Measuring errors can occur when measuring
toward colorless liquids (e.g. water) or dust free
glass, Styrofoam or similar semi-permeable surfaces.
Aiming at high gloss surfaces may deflect the laser-
beam and lead to measurement errors.
Hazards of Use
CAUTION:
Watch out for erroneous distance measure-
ments if the instrument is defective or if it has been
dropped or has been misused or modified.
Precautions:
Carry out periodic test measurements.
Particularly after the instrument has been subject to