Fluke Calibration 2700G Series Скачать руководство пользователя страница 2

LIMITED WARRANTY AND LIMITATION OF LIABILITY

 

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is 
one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to 
the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product 
which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation 
or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has 
been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. 
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to 
extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke 
authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of 
repair/replacement parts when product purchased in one country is submitted for repair in another country. 
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective 
product which is returned to a Fluke authorized service center within the warranty period. 

uke assumes no risk 

for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke 
determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal condition of operation or handling, 
including overvoltage failures caused by use outside the product’s specified rating, or normal wear and tear of mechanical components, 
Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be 
returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping 
Point). 
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR 
IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR 
LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. 
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or 
consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held 
invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability 
of any other provision. 

11/99                                                 

www.

.com

[email protected]

1.800.561.8187

Содержание 2700G Series

Страница 1: ...tion All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies 2700G Series Reference Pressure Gauge Users Manual www com i...

Страница 2: ...repair or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period uke assumes no risk for damage in transit Following warranty repair the p...

Страница 3: ...ard Equipment 2 Safety Information 2 Special Conditions for Safe Use 3 Symbols 4 Display and Buttons 5 Operation 6 How to Setup the Product 6 Engineering Units 6 Set Auto Off 7 Show Battery Voltage 7...

Страница 4: ...an the Product 9 How to Change the Batteries 10 Accessories 11 USB Interface Cable 11 Power Module 11 Serial Interface Instructions 13 Initiating Communication 13 List of Commands 13 Parameter Units 1...

Страница 5: ...iii List of Tables Table Title Page 1 Symbols 4 2 Display and Buttons 5 3 Units Conversion 16 www com information itm com 1 800 561 8187...

Страница 6: ...v List of Figures Figure Title Page 1 The Product 5 2 Change the Batteries 10 3 USB Power Module and Universal Connectors 12 www com information itm com 1 800 561 8187...

Страница 7: ...ference or in applications where high accuracy pressure measurement is required The Product features user configurable functions that include Sampling rate Tare Damping Auto off Min Max When the Produ...

Страница 8: ...le and operate high pressure systems if you know the correct safety procedures High pressure liquids and gases are hazardous and the energy from them can be released without warning To prevent possibl...

Страница 9: ...torque specified Maximum torque specified is 20 Nm 15 ft lb Special Conditions for Safe Use Misuse If the Product is exposed to overpressure or sudden physical shock such as being dropped examine it f...

Страница 10: ...relevant Australian standards This product complies with the WEEE Directive 2002 96 EC marking requirements The affixed label indicates that you must not discard this electrical electronic product in...

Страница 11: ...uct Zeros the display In Configure Mode push the button to move forward through the menus MIN MAX records minimum and maximum pressure values and saves them to memory Push to show maximum MAX indicati...

Страница 12: ...ord a Tare value the pressure shown is not the actual pressure applied How to Setup the Product Before you use the product it is necessary to configure it for your application Push to go to the Setup...

Страница 13: ...tions are on and off Damping smooths readings from pulsating pressure sources Set Sample Rate This function finds how many times pressure is sampled and the display is updated Selections are 0 5 1 3 a...

Страница 14: ...word entry Hold or down to move faster through the selections by a factor of 10 When you stop the counter push and again to move forward or backward by a factor of 1 The password is factory set and ca...

Страница 15: ...eration with the backlight off When the battery voltage is low the low battery icon shows on the top left of the display To replace the batteries see the How to Change the Batteries section Maintenanc...

Страница 16: ...batteries see Figure 2 1 Pull off the Product cover 2 Use a Phillips screwdriver to loosen the captive screw on the battery door 3 Remove the battery door 4 Replace the three AA batteries 5 Install th...

Страница 17: ...is on the back of the Product You can use serial communication to configure and calibrate the Product and move measurement data from the Product to a PC For specifications on the interface see the Sp...

Страница 18: ...2700G Series Users Manual 12 gsn003 eps Figure 3 USB Power Module and Universal Connectors www com information itm com 1 800 561 8187...

Страница 19: ...ent list of commands to communicate with the Gauge CLS Clears the error queue FAULT Returns an error code from the error queue IDN Identification query Returns the manufacturer model number and firmwa...

Страница 20: ...meter Units The subsequent list of units is used with the Product psi Pressure in pounds per square inch bar Pressure in bars mBar Pressure in millibars kg cm2 Pressure in kilograms per centimeter squ...

Страница 21: ...s The gauge uses the subsequent error codes 101 A non numeric entry was received where it should be a numeric entry 102 Too many significant digits entered 103 Invalid units or parameter value receive...

Страница 22: ...tor from kPa Conversion Factor to kPa psi 0 14503773773 6 894759 bar 0 01 100 MPa 0 001 1000 kgf cm2 0 010197162130 98 06652 inH2O 4 C 4 014742 0 249082 inH2O 20 C 4 021845 0 248642 inH2O 60 F 4 01858...

Страница 23: ...Factor to kPa cmH2O 4 C 10 19744 0 09806383 cmH2O 20 C 10 21549 0 09789056 mH2O 4 C 0 1019744 9 806383 mH2O 20 C 0 1021549 9 789056 kPa 1 1 mbar 10 0 1 inHg 0 C 0 2952998 3 386387 mmHg 0 C 7 500618 0...

Страница 24: ...an dry non corrosive gas 100 300 500 1000 psi any liquids or gases compatible with 316 stainless steel Above 1000 psi any non flammable non toxic non explosive non oxidizing liquid or gas compatible w...

Страница 25: ...5 x 5 in depth 1 5 in Without Protective Cover Pressure Connection in NPT Male Housing Cast ZNAL Display 5 1 2 Digits 16 53 mm 0 65 in high 20 Segment bar graph 0 to 100 Power Battery three size AA a...

Страница 26: ...3000 5000 10000 Pressure Range MPa 0 1 0 2 0 7 2 3 5 7 20 35 70 Vacuum Range psi 15 15 12 12 12 12 0 0 0 Vacuum Range kPa 100 100 80 80 80 80 0 0 0 Burst Pressure psi 45 90 1000 2000 2000 10000 10000...

Отзывы: