Fluigent FLOW UNIT Скачать руководство пользователя страница 3

4

5

The FLOW UNIT range provides a solution for measuring and/

or controlling flow- rates for any fluidic applications. Combining 

the FLOW UNIT with our pressure handling system (Flow EZ

TM

 or 

Flowboard combined with MFCS

TM

)  will give you the opportu-

nity to check at all times flow-rate and volume of liquids flowing 

through your fluidic system. The four different FLOW UNIT models 

offer an extensive choice of flow-rate ranges to best match your 

required precision, f rom 8 nL/min to 40 mL/min. Beside water 

based solutions, a second calibration for hydrocarbons is available 

on three (3) different FLOW UNIT models (S, M+ and L+), see §8.

INTRODUCTION

INTRODUCTION

This user manual will show you how to install and use flow units in your 

daily work. It will describe all the Flow unit functionalities and will help 

you to connect all the different FLOW UNIT models  and to use it with 

all the equipment: with Fluigent  Flow EZ

TM

 and MFCS

TM

-EZ

General information

The Flow Unit enables flow-rate measurements, in a wide range of 

flow-rates thanks to the five (5) models: XS, S, M+, L+.

The flow-rate acquisition is based on a thermal technology. A heating 

element on the microchip adds a minimal amount of heat to the 

medium for the thermal flow measurement. Two temperature sensors, 

symmetrically located above and below the source of the heat, detect 

even the slightest temperature differences, thus providing the basic 

information about the spread of the heat, which itself is directly related 

to the flow- rate.

Technology principle

This user manual will show you how to install and use flow units in your 

daily work. It will describe all the Flow unit functionalities and will help 

you to connect all the different FLOW UNIT models  and to use it with 

all the equipment: with Fluigent  Flow EZ

TM

 and MFCS

TM

-EZ

Содержание FLOW UNIT

Страница 1: ...USER S MANUAL FLOW RATE PLATFORM FLOW UNIT FLOW UNIT...

Страница 2: ...vice department support fluigent com Prevent any objects or liquid from entering the Flowboard and FLOW UNITs this may cause a short circuit failure or other malfunction Failing to respect this advice...

Страница 3: ...will help you to connect all the different FLOW UNIT models and to use it with all the equipment with Fluigent Flow EZTM and MFCSTM EZ General information The Flow Unit enables flow rate measurements...

Страница 4: ...bove 4 2 L min 210 nL min below 4 2 L min 5 m v above 10 L min 0 5 L min below 10 L min 10 m v above 50 L min 5 L min below 50 L min 5 m v above 1 mL min 50 L min below 1 mL min 10 m v above 2 mL min...

Страница 5: ...le with 1 32 or 1 16 OD tubing nuts and ferrules from fittings suppliers to suit your application XS S tubing fittings FLOW UNIT DESCRIPTION The two 2 fluidic ports are on the sides of the device The...

Страница 6: ...bottom type FB Compatible with tubings of 1 16 external diameter 1 16 OD To get started FLUIGENT can provide you the CTQ_KIT_HQ kit including Two 2 Flow Unit HQ connector 28 Flat Bottom for 1 16 OD t...

Страница 7: ...ten the nut finger tight 4 To check the tightness of your connection you may pull gently on the tubing it must stay fitted in the ferrule and nut 5 Do the same thing on the 2nd port 1 2 4 3 SETTING UP...

Страница 8: ...ted to the Flow EZTM and to the fluidic system reservoir and chip flow rate can be measured either directly on the Flow EZTM in local mode or by using OxyGEN SETTING UP Local mode measure and control...

Страница 9: ...n the reservoir Pmeas is still displayed in the middle giving information on the fluidic set up Abnormal flow rates may reflect problems in the microfluidic set up leakage clogging etc For control usi...

Страница 10: ...u just need to launch the Oxygen software The Oxygen software will automatically detect the instrument connected to the flowboard and show immediately the flow rate measure of each connected flow unit...

Страница 11: ...r the use of our FLOW UNIT sensor range without Flow EZTM the Flowboard is a product that must be used This device hosts up to eight 8 FLOW UNIT models and provides them power supply The Flowboard is...

Страница 12: ...FCS series flow controller It can be used to measure and display flow rate with any flow control system On the back of the FLOWBOARD a table summarizes all the FLOW UNIT models available and their cha...

Страница 13: ...the Oxygen user manual in the following link https www fluigent com resources support support tools downloads user manuals The flow rate graph reports the current flow rate sensor measurements If flow...

Страница 14: ...that most closely matches your fluid For example water calibration can be used for water based solution and isopropyl alcohol calibration for hydrocarbons or oil The calibration can be selected and sw...

Страница 15: ...EZ Then simultaneously you record the flow rate given by the software and you measure the weight of fluid you have collected over a chosen period of time Knowing the density of the fluid you are able...

Страница 16: ...Before storing the sensor always drain of fluid flush with cleaning agent blow out and dry the capillary Procedure Cleaning and flushing of the Flow Units should consider the nature of the materials t...

Страница 17: ...when IPA is followed by water in a sensor without drying in between large offsets can be observed for hours after switching to water If possible dedicate a separate sensor for each different liquid to...

Страница 18: ...ref 244511 Sigma Aldrich Mineral oil Sigma cat no 5904 RBS 25 ref 83460 Sigma Aldrich Blood BD FACS Clean RBS 25 ref 83460 BD Sigma Aldrich Component Servicing interval All system Regular inspection f...

Страница 19: ...location with a level surface and a strong and stable support Respect the temperature compatibility from 5 C to 50 C Filter your solution if possible add a filter in the fluidic path 10 and clean your...

Отзывы: