SAFETY INSTRUCTIONS 

Any responsibility is lapsed if the instructions and procedures as described in this manual are not 
followed. 

 

LIFE SUPPORT APPLICATIONS: The F115-P is not designed for use in life support 
appliances, devices, or systems where malfunction of the product can reasonably be 
expected to result in a personal injury. Customers using or selling these products for 
use in such applications do so at their own risk and agree to fully indemnify the 
manufacturer and supplier for any damages resulting from such improper use or sale. 

 

Electro static discharge does inflict irreparable damage to electronics! Before 
installing or opening the unit, the installer has to discharge himself by touching a well-
grounded object. 

 

This unit must be installed in accordance with the EMC guidelines (Electro Magnetic 
Compatibility). 

 

Do connect a proper grounding to the metal enclosure as indicated if the F115-P has an 
incoming power line which carries a 115-230V AC. The Protective Earth (PE) wire may 
never be disconnected or removed. 

 

Intrinsically safe applications: follow the instructions as mentioned in Chapter 5 and 
consult “Fluidwell F1..-..-XI - Documentation for Intrinsic safety”.  

  

 

DISPOSAL OF ELECTRONIC WASTE 

  The WEEE Directive requires the recycling of disposed electrical and electronic equipment in the 

European Union. When the WEEE Directive does not apply to your region, we support its policy 
and ask you to be aware on how to dispose of this product. 

  The crossed out wheelie bin symbol as illustrated and found on our products tells that this 

product shall not be disposed of into the general waste system or into a landfill. 

  At the end of its life, equipment shall be disposed of according to the local regulations regarding 

waste of the electrical and the electronic equipment. 

 

Please contact your local dealer, national distributor or the manufacturer’s Technical helpdesk for 
information on the product disposal. 

 
 

SAFETY RULES AND PRECAUTIONARY MEASURES 

 

The manufacturer accepts no responsibility whatsoever if the following safety rules and 
precautions instructions and the procedures as described in this manual are not followed. 

 

Modifications of the F115-P implemented without preceding written consent from the 
manufacturer, will result in the immediate termination of product liability and warranty period. 

  Mounting, electrical installation, start-up and maintenance of this device may only be carried out 

by trained persons authorized by the operator of the facility. Persons must read and understand 
this manual before carrying out its instructions. 

  This device may only be operated by persons who are authorized and trained by the operator of 

the facility. All instructions in this manual are to be observed. 

 

Check the mains voltage and information on the manufacturer's plate before installing the unit. 

 

Check all connections, settings and technical specifications of the various peripheral devices 
with the F115-P supplied. 

 

Open the enclosure only if all leads are free of potential. 

 

Never touch the electronic components (ESD sensitivity). 

 

Never expose the system to heavier conditions than allowed according the classification of the 
enclosure (see manufacture's plate and chapter 4). 

 

If the operator detects errors or dangers, or disagrees with the safety precautions taken, then 
inform the owner or principal responsible. 

 

The local labor and safety laws and regulations must be adhered to. 

 
 

 

Содержание F115-P

Страница 1: ...puts Signal input flowmeter pulse Namur and coil Signal outputs 0 4 20mA 0 10V ref flow rate and pulse ref total and flow direction Options Intrinsically safe Modbus communication and backlight F Seri...

Страница 2: ...FW_F115P_v1702_02_EN Page 2...

Страница 3: ...the general waste system or into a landfill At the end of its life equipment shall be disposed of according to the local regulations regarding waste of the electrical and the electronic equipment Plea...

Страница 4: ...connected instruments A caution indicates actions or procedures which if not performed correctly may lead to personal injury or incorrect functioning of the F115 P or connected instruments A note ind...

Страница 5: ...Pulse 17 3 1 11 Explanation of SETUP menu A Communication option 18 3 1 12 Explanation of SETUP menu B Others 18 4 Installation 19 4 1 General directions 19 4 2 Installation surrounding conditions 19...

Страница 6: ...eter signals transmitting possibilities with analog pulse and communication outputs Flowmeter input This manual describes the unit with a pulse input from the flowmeter Other versions are available to...

Страница 7: ...backlight to show the process information status and alarm messages The display refresh rate is programmed in the setup menu At a key press the display refresh rate will switch to FAST for 30 seconds...

Страница 8: ...t for users operators 2 1 CONTROL PANEL The control panel has three keys The available keys are Fig 2 Control Panel Functions of the keys This key is used to program and save new values or settings Th...

Страница 9: ...ollowing information is shown in case of reverse flow flow rate will be negative and total will count down or flow rate value will be zero and no totalization or flow rate will be positive and total w...

Страница 10: ...ossible to prevent access to the setup menu with a password A password may be required to enter the setup menu Without this password access is denied 3 1 HOW TO PROGRAM THE F115 P The setup menu has d...

Страница 11: ...d the setting UNIT When you do not want to save the change wait for approximately 20 seconds or press and hold the PROG ENTER key for approximately 3 seconds Action Result Remark 1 Momentarily press t...

Страница 12: ...6 POWER MANAGEMENT 61 LCD new fast 1 sec 3 sec 15 sec 30 sec off 62 battery mode operational shelf 7 FLOWMETER 71 signal A npn npn lp reed reed lp pnp pnp lp namur coil hi coil lo 8 1 DC 12 DC 24 DC 7...

Страница 13: ...ses per m3 So the K Factor is 2481 3 Enter for the Flowmeter K Factor 24813 and for the flowmeter K Factor decimals 1 Example 2 Calculating the K Factor The flowmeter generates 6 5231 pulses per gallo...

Страница 14: ...Factor the flowmeter pulse signals are converted to a quantity The K Factor is based on the number of pulses generated by the flowmeter per selected engineering unit for example per m3 A more accurate...

Страница 15: ...shelf has been selected the F115 P can be stored for several years it will not process the sensor signal the display is switched off but all settings and totals are stored In this mode power consumpt...

Страница 16: ...t up Reverse flow rate will be calculated signed negative Total accumulated total and Total B will count down 3 1 9 EXPLANATION OF SETUP MENU 8 ANALOG OUTPUT A linear 4 20mA signal option AB 0 20mA or...

Страница 17: ...al filter a more stable but less actual representation of the flow rate can be obtained The filter principal is based on three input values the filter level 01 99 the last calculated flow rate and the...

Страница 18: ...twork the product and the communication against any kind of security breaches The functions described below deal with hardware that is not part of the standard delivery Programming of these functions...

Страница 19: ...en the housing cover is removed or the panel cabinet has been opened danger from electrical shock The housing may only be opened by trained persons authorized by the operator of the facility Take care...

Страница 20: ...mm 30mm M20 x 1 5 M16 x 1 5 M16 x 1 5 30mm 30mm M20 x 1 5 M20 x 1 5 M20 x 1 5 25mm 25mm 1 2 NPT 0 9 3x 1 2 NPT 0 12 0 12 HA HM HN HO HP HT HU 6 x M12 12mm 12mm 24mm 24mm 36mm 36mm 14mm 17mm 115 mm 4 5...

Страница 21: ...120 mm 4 72 HD HK HK back box flat bottom HE HF HG HH D 12mm 12mm 12mm 24mm 24mm 36mm 36mm 14mm 17mm 22 5mm 30mm 30mm D 16mm D 20mm 0 9 D 22mm 0 866 22 5mm 25mm 25mm D 20mm D 20mm D 16mm HC 75 mm 2 9...

Страница 22: ...that came with a power module type PM 110V 230V AC or type PD PF with an option OR the relays can handle 110V 230V AC shall be connected to the Protective Earth PE stud which is installed in the metal...

Страница 23: ...screws that attach the cover to the back panel Type PM 110 230V AC The PE connection in the metal back panel is made with a serrated washer a terminal a washer and a screw The PE connection to the me...

Страница 24: ...C GRP ENCLOSURE The PE connection The F115 P in a GRP enclosure meets the requirements of class 2 double insulated Therefore the incoming PE wire is terminated with an insulating end cap Type PM 110 2...

Страница 25: ...r All energy used by the flowmeters pick up will directly influence the battery life time It is strongly advised to use a zero power pickup such as a coil or reed switch when operating without externa...

Страница 26: ...in AC 14Vin DC 24V DC 18Vin AC 26Vin DC Type PF Power supply in 15 24V AC 20 30V DC Switch location typical Sensor Vout selection Sensor supply out A B 1 2 3 4 int int off off Coil 1 2V DC 1mA Reed 3V...

Страница 27: ...tions Active output typical Type OR A mechanical relay output according the functions R1 and R2 is available with this option Max switch power 240V 0 5A per output Requires power supply type PD PF PM...

Страница 28: ...n these terminals Max driving capacity 1000 Ohm 24VDC Requires power supply type PD PF PM Fig 12 Terminal connections 4 20mA analog output typical Type AB An active 0 20mA signal proportional to the f...

Страница 29: ...flowmeter signals can be connected to the unit pulse active pulse or coil Only the connection diagrams for flowmeter A are given The connections for flowmeter A Terminal 09 11 and B Terminal 12 14 are...

Страница 30: ...s to go above 1 2V Signal setting PNP LP employs a low pass signal noise filter which limits the maximum input frequency read chapter 3 A sensor supply voltage of 8 2 12 or 24V DC can be provided with...

Страница 31: ...on RS232 RS485 TTL option For connections refer to figure Overview of terminal connectors Standard configuration and options Full serial communications and computer control in accordance with RS232 le...

Страница 32: ...ith IEC 60529 suitable cable entries and blanking elements must be used and correctly installed For enclosures and windows with a high surface resistance potential charging hazard exists Do not rub th...

Страница 33: ...Classification of the unit as group IIC is only possible under the following conditions The indicator is either supplied by the internal supply type PC the external supply connected to terminals 0 an...

Страница 34: ...able with this option When the output is disabled a 3 5mA signal will be generated Max driving capacity 1000 Ohm 30V DC Fig 26 Terminal connections Intrinsically safe floating 4 20mA analog output typ...

Страница 35: ...k of electrocution High voltage Make sure all the leads to the terminals are disconnected from the F115 P and NEVER connect the mains power supply to the unit when the protection cover has been remove...

Страница 36: ...FW_F115P_v1702_02_EN Page 36 Fig 29 F115 P AP CT OT PC XI Battery powered IIB IIC IIIC...

Страница 37: ...FW_F115P_v1702_02_EN Page 37 Fig 30 F115 P AP CT OT PX XI Output loop powered IIB IIC IIIC Fig 31 F115 P AF CT OT PD XI External power supply IIB IIC IIIC...

Страница 38: ...with the utmost care to prevent a short circuit and damage 4 Do not recharge crush disassemble incinerate heat above its rated temperature or expose the contents to water 5 Dispose of the battery in a...

Страница 39: ...nalog output signal be sure that an external power supply is connected or that the function is disabled if not in use or else it will have a major influence on the battery life time Display update fas...

Страница 40: ...M20 Drilling 2x M20 Drilling 6x M12 Drilling 1x NPT Drilling 3x NPT Drilling 4x M20 No drilling No drilling Drilling 2x 16mm 0 63 1x 20mm 0 78 Drilling 1x 22mm 0 87 Drilling 2x 20mm 0 78 Drilling 3x...

Страница 41: ...output Function transmitting flow rate Accuracy 10 bit Error 0 05 update 10 times a second Software function to calibrate the 4 00mA and 20 00mA levels precisely within set up Load max 1 kOhm Type AA...

Страница 42: ...by pressing the CLEAR key twice Totals Digits 7 digits Units L m3 kg lb GAL USGAL bbl no unit Decimals 0000000 111111 1 22222 22 3333 333 Note differential total can be reset to zero Accumulated tota...

Страница 43: ...tion Check amount pulse per x quantity is the value programmed reasonable and will the maximum output be under 20Hz width is the external device able to recognize the selected pulse width and frequenc...

Страница 44: ...ters sometimes require you to manually calculate the resulting value For additional information regarding using your Modbus device please read our General Modbus Communication Protocol and Modbus trou...

Страница 45: ...d 50 h 0x032 40051 decimals 1 r w uint16 0 3 d 51 h 0x033 40052 K factor 2 r w uint32 1 9999999 Representation 0 000010 9999999 depending on variable 54 decimals K factor d 54 h 0x036 40055 decimals...

Страница 46: ...or 1 r w uint16 0 Single 1 Dual d 140 h 0x08C 40141 calculate 1 r w uint16 0 diff 1 add PDU ADDRESS REGISTER VARIABLE ANALOG NO REGISTERS R W TYPE VALUE REMARKS d 112 h 0x070 40113 output 1 R W uint16...

Страница 47: ...0x0F7 40248 databits 1 r w uint16 0 7bits 1 8bits d 248 h 0x0F8 40249 parity 1 r w uint16 0 none 1 even 2 odd PDU ADDRESS REGISTER VARIABLE OTHERS NO REGISTERS R W TYPE VALUE REMARKS d 173 h 0x0AD 40...

Страница 48: ...FW_F115P_v1702_02_EN Page 48 APPENDIX D DECLARATION OF CONFORMITY...

Страница 49: ...Terminal connections Mechanical relay output typical 27 Fig 11 Terminal connections Passive transistor output typical 27 Fig 12 Terminal connections 4 20mA analog output typical 28 Fig 13 Terminal co...

Страница 50: ...actor total A 32 decimals K factor total A 4 FLOW RATE B 41 K factor flow rate A 42 decimals K factor flow rate A 5 DISPLAY 51 function total 52 show a b enable 52 light 100 6 POWER MANAGEMENT 61 LCD...

Страница 51: ...ed 92 width 0 000 93 decimals 0000000 94 amount 1000 A COMMUNICATION A1 baud rate 9600 A2 address 1 A3 mode BUS RTU A4 databits 8 bits A5 parity none B OTHERS B1 model F115 P B2 s vers 03 __ __ B3 ser...

Страница 52: ...Fluidwell B V PO box 6 Voltaweg 23 Website www fluidwell com 5460 AA Veghel 5466 AZ Veghel Find your nearest representative www fluidwell com representatives the Netherlands the Netherlands 2017 Fluid...

Отзывы: