FW_F112A_v1702_02_EN
Page 42
Setup variables
PDU
ADDRESS
REGISTER VARIABLE
TOTAL
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 32
[h] 0x020
40033
unit
1
r/w uint16 0=none
1=L
2= m
3
3=kg
4= lb
5=gal
6= US GAL
7=bbl
[d] 33
[h] 0x021
40034
decimals
1
r/w uint16
0…3
[d] 34
[h] 0x022
40035
span
2
r/w uint32 1...9999999
Representation: 0.000001…9999999 depending on
variable 54: decimals span.
[d] 37
[h] 0x025
40038
decimals span
1
r/w uint16
0…6
PDU
ADDRESS
REGISTER VARIABLE
FLOWRATE
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 48
[h] 0x030
40049
unit
1
r/w uint16 0=mL
1=L
2= m
3
3=mg
4=g
5=kg
6=ton
7=GAL
8=bbl
9=lb
10=cf
11=rev
12=none
13=scf
14=NM
3
15=NL
16=p
[d] 49
[h] 0x031
40050
time unit
1
r/w uint16 0=/sec
1=/min
2=/hour
3=/day
[d] 50
[h] 0x032
40051
decimals
1
r/w uint16
0…3
[d] 51
[h] 0x033
40052
span
2
r/w uint32 1...9999999
Representation: 0.000001…9999999
depending on variable 54: decimals span.
[d] 54
[h] 0x036
40055
decimals span
1
r/w uint16
0…6
PDU
ADDRESS
REGISTER VARIABLE
DISPLAY
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 64
[h] 0x040
40065
display function
1
r/w uint16 0=total
1=flow rate
[d] 67
[h] 0x043
40068
backlight brightness
1
r/w uint16 0=off
1=20%
2=40%
3=60%
4=80%
5=100%
PDU
ADDRESS
REGISTER VARIABLE
POWER MANAGEMENT
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 80
[h] 0x050
40081
LCD update time
1
r/w uint16 0=fast
1=1sec
2=3sec
3=15sec
4=30sec
5=off
[d] 81
[h] 0x051
40082
power mode
1
r/w uint16 0=operational
1=shelf
PDU
ADDRESS
REGISTER VARIABLE
LINEARIZATION
NO.
REGISTERS
R/W
TYPE
VALUE / REMARKS
[d] 1024
[h] 0x400
41025
percentage/M-factor
3
r/w uint48 The linearization table is an INDEXED variable.
Reading and writing the entries of the linearization
tables is done by first selecting the entry through
the index. Valid values for the index are 0…14,
which correspond with the linearization table entries
1 through 15. Indexes outside this range will result
in an error being sent back.
(See the communication-section of this appendix for
setting the index and its extended functionality
through variable 150 and 149).
The 3 registers represent a structure containing 2
variables of each 3 bytes. The three least significant
bytes (PDU address 1024 and LSB of PDU address
1025) contain the percentage part, the three most
significant bytes (MSB of PDU address 1025 and
PDU address 1026) contain the M-factor part.
Valid range for the percentage is (0)4-20mA..
A value of 0 for percenatge means that entry is
disabled.
Valid range for the M-factor 0.000000 to 9.999999.
[d]1038
[h]0x40E
41039
Linearization on/off
1
r/w uint16 0=disable
1=enable