![Fluidwell F014-P Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/fluidwell/f014-p/f014-p_manual_2308987038.webp)
Page 37
FW-F014-P-M_v0402_05_EN.docx
Power requirements
Type PB Lithium battery - life-time depends upon settings - up to 5 years.
Type PC Intrinsically Safe lithium battery - life-time depends upon settings - up to 5 years.
Type PD 16-30 V DC. Power consumption max. 1 Watt.
Type PF 24V AC/DC +10%. Power consumption max. 15 Watt.
Type PL Input loop powered from 4-20mA signal input. Voltage drop max. 2.6V DC
Type PM 115-230V AC +10%. Power consumption max. 15 Watt.
Type PX 8-30 V DC (also available with PB / PC). Power consumption max. 0.3 Watt.
Type ZB
20-30V DC. Power consumption max. 1 Watt. Note: with type PF / PM: internally powered.
PF / PM:
The total consumption of the sensor, transistor output type OA and backlight
type ZB may not exceed 400mA@24V DC.
IS application:
For intrinsically safe applications, consult the safety values in the certificate.
Sensor excitation
Type PB / PC / PX
Sensor supply voltage: 3.2V DC for pulse signals and 1.2V DC for coil pick-up.
Please note: this is not a real sensor supply. Only suitable for sensors with a very low power
consumption like coils (sine wave) and reed-switches.
Analog sensors type A / U: sensor supply not available.
Type PD
With pulse input type P: sensor supply 1.2, 3.2, 8.2V DC - max. [email protected] DC.
With analog input type A / U: as connected power supply voltage (internally linked)
Type PF / PM
Analog sensors type A / U: sensor supply 8.2, 12 and 24V DC - max. 400mA@24V DC
With pulse input type P: sensor supply 1.2, 3.2, 8.2, 12 and 24V DC - max. 400mA@24V DC
Terminal connections
Type:
Removable plug-in terminal strip. Wire max. 1.5mm2 and 2.5mm2
Data protection
Type
EEPROM backup of all settings. Data retention at least 10 years.
Pass code
Configuration settings can be pass code protected.
Hazardous area (option)
Intrinsically safe
Type XI
ATEX approval:
II 1 G Ex ia IIC T4
II 1 D Ex iaD 20 IP 65 / 67 T 100°C
IECEx approval:
Ga Ex ia IIC T4
Ex iaD 20 IP 65 / 67 T 100°C
CSA / FM approval :
IS Class I/II/III, Division 1 Groups A to G T4
Class I zone 0 AEx ia IIC T4
Explosion proof
Type XF
ATEX approval ref.: <EX> II 2 GD EEx d IIB T5. Weight appr. 15kg.
Dimensions of enclosure: 350 x 250 x 200mm (13.7” x 9.9” x 7.9”) LxHxD.