Troubleshooting
Using the chart below, locate the problem in the first column, then select the
probable cause to check and action to take from the next two columns. The
problems are arranged from the simplest to the most complex.
Where appropriate, refer to the Servicing and Repair section to correct the
problem.
PROBLEM
CHECK
ACTION
The paint mixer does not start.
if mixer attached to receptacle.
receptacle for voltage.
if front door is not closed.
POWER switch is in the ON
position and operating properly. The
EMERGENCY STOP button should
not be depressed.
6.3 amp fuse.
5 amp Slow-Blow fuse.
PCB connector.
may be a problem with printed circuit
board.
• Connect to power source.
• Contact electrician.
• Close the front door.
• Turn on POWER switch. Put the
EMERGENCY STOP button in the
ON position.
• Replace fuse.
• Replace fuse.
• Reestablish PCB connector.
• Call Customer Service.
• Replace printed circuit board.
The top plate does not move in a
downward direction.
loose/broken wire in the DC motor
cable.
START switch mechanism on the
control panel for a loose connection.
DC motor.
may be a problem with printed circuit
board.
• Reconnect loose wire or replace
broken wire.
• Tighten connections at the START
switch.
• Replace START switch mechanism.
• Using voltmeter, measure voltage at
DC motor or call Customer Service.
• Replace DC motor.
• Call Customer Service.
• Replace printed circuit board.
22 | Harbil 5G Mixer
Fluid Management Customer Service 1.800.462.2466
Troubleshooting