Flue & Ducting GO-FLUE Скачать руководство пользователя страница 3

 

leakage. Dura Flue can also be power swept both 
ways. 
 
INSTALLATION: Where any bends occur in the chimney it 

would be advisable to remove a small hole in the wall 
to ensure the liner has to been installed properly. 
 
 

 

We advise that the installation is at least a two man job. 
Attach the nose cone and string to what will be the 
bottom of the liner. 
Installer 1 takes the liner to the top of the chimney and 
drops down the string. 
Installer 2 collects the string at the bottom ensuring that 
the liner does not snag or catch any obstacles on the 
way down. 
Installer 1 twists the liner down the flue ensuring that it 
doesn’t snag or catch any obstacles on the way down 
and Installer 2 pulls the string. 
 
 

 

 

NOTE: To ensure the diameter will fit, draw a 1 metre 
length of the liner in the diameter you are planning to 
use through the chimney first (do not use full lengths or 
smaller pieces taped together). 

 
Once the liner is fully down the flue, connect all 
required adaptors, clamps and plates using suitable 
sealant for wood/multi fuel appliances and self-taping 
screws (not supplied in this pack). 
Put back on chimney pot and flaunch back as 
required. 
If the original masonry flue is larger than 9” x 9” or/and is 
on an outside wall, Flue and Ducting Ltd highly 
recommend the liner is insulated. This decision is to be 
made by the HETAS registered installer. 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 