BS EN 1856-2:2004

 

 

 

 

BS EN 1856-2:2004

 

 

 

 

 

GO-FLUE CHIMNEY LINER 

 
GO-FLUE is suitable for use with oil,  atmospheric gas 
and kerosene appliances where the flue gas 

temperature does not exceed 260°C.  
 
There are several specific elements increasing the value 
of the system: 
 

 

 
Those adaptors are CE marked with the system – other 
adapters are suitable. 
 
 

 

 

 

 
 
 

MATERIALS: 

 
CONSTRUCTION: 
single ply 
MATERIALS: 316 

 

FUELS: 

 
Go Flue can be used with oil, gas and kerosene and all 
kinds of fuels provided the working conditions stated in 
the designation numbers are fulfilled and the fuels are 
HETAS approved. 
 
 

DIAMETERS: 

 
STANDARD: 3”, 4”, 5”, 6”, 7”, 8”, 10”, 12” 
 
 

APPROVALS: 

 

 

T200 P1 W V2 L50010 O 
T400 N1 D V2 L50010 G 
 

APROVED PRODUCTION SITES: 

 
STOCKPORT: 
Unit D6, Stockport Trading Estate, Yew Street, Stockport 
SK4 2JZ 
WELLINGTON: 
8E Castle Road, Chelston Business Park, Wellington TA21 
9JQ 
NORMANTON: 
Unit 9 Ripley Close, Normanton Industrial Estate, 
Normanton, Yorkshire WF6 1TB 
 
 

DISTANCES & MEASURES:

 

 
INSULATION: Go-Flue should be insulated whenever 
possible especially when installing on gable ends and in 
flues larger than 9” x 9”. 
 
CHIMNEY: The structure of the chimney must be at least 
4” thick (100mm) to comply with current building 
regulations. 
 
 

TIPS & TRICKS: 

 
BEFORE INSTALLATION: Make sure the masonry flue is 
swept thoroughly by a competent person to ensure that 
all soot and tars have been removed as best as 
possible. Soot and tar within the chimney may corrode 
the liner. 
 
CHIMNEY: The structure of the chimney must be sound 
and must be wind and water tight. It is recommended 
to remove any existing pots, dampers or obstructions 
before you start to allow full access. 
 
EITHER WAY UP: 
Due to its unique construction, Dura Flue 
can be installed in either direction without risk of 