FLS FlowX3 F9.20 Скачать руководство пользователя страница 4

 
 
 

 

2. Description 

 
 

2.1.  Design 

 

 

The FLS FlowX3 F9.20 Battery Powered Flow Monitor is equipped with two long life 
lithium batteries and it integrates the power supply for the sensor. It is designed to 
show on the LCD display flow rate and totalized flow volume with no external power 
supply required. One of the two totalizers is resettable while the other is non-resettable 
and it is used to permanently record volume consumption. Self explaining calibration 
menus allow a customized setup of all measuring parameters and the state of the art 
electronic design ensures long-term reliable and stable indications. The high flexibility 
is maximized with only one packaging for compact pipe mount, panel or wall 
installation. 

 

 

2.2.  Technical Features 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

 

2.3.  Connection to FlowX3 Sensors 
   

 

 

FlowX3 Sensors 

FlowX3 

Monitor 

F3.00.H 

F3.00.C 

F3.01.H 

F3.01.C 

F3.15.H* 

F3.30.H* 

ULF.H 

ULF.R 

ULF3.15* 

ULF3.30* 

F111.H 

F111.C 

F9.20 

 

 

   X     

 

 

* with Output Kit mounted 

 

F9.20 Battery Powered Flow Monitor

Содержание FlowX3 F9.20

Страница 1: ...owX3 Sensors 4 3 Specifications 5 3 1 Technical Data 5 3 2 Dimensions 6 4 Installation 7 4 1 Panel Installation 7 4 2 Wall Installation 8 4 3 Compact Installation 8 4 4 Wiring 9 5 Operational Overview...

Страница 2: ...Backup 16 8 4 Options Menu 17 8 4 2 Filter 17 8 4 3 Flow Decimal Point 18 8 4 4 Total Decimal Point 18 8 4 7 Menu PWD 19 8 4 8 Restot PWD 19 8 4 9 K Factor Calculate 20 9 Troubleshooting 21 9 1 Displ...

Страница 3: ...struction Installation and Commissioning Statements To clean the unit use only chemical compatible products 1 2 Unpacking Please verify that the product is complete and without any damage The followin...

Страница 4: ...to permanently record volume consumption Self explaining calibration menus allow a customized setup of all measuring parameters and the state of the art electronic design ensures long term reliable an...

Страница 5: ...osure IP65 front Electrical Supply Voltage 2 x 3 6 Volt Lithium thionyl chloride battery 2 8 Ahr Battery life nominal 5 years Sensor Input Frequency Sensor power 3 6 Volt Range 1 to 500 Hz Environment...

Страница 6: ...3 2 Dimensions Compact Mount Panel Mount Wall Mount F9 20 Battery Powered Flow Monitor 6...

Страница 7: ...ctly fits into a standard DIN panel cutout 1 Cut out the panel the F9 20 requires a panel opening of 90 5 x 90 5 mm 3 563 x 3 563 DIN punches are recommended alternatively a jigsaw or another cutting...

Страница 8: ...astic adapter with gasket for IP65 watertight installation the sensor gasket the compact cap the locking ring and four fixing screws 1 Assemble the sensor gasket in the proper 2 ate the sensor gasket...

Страница 9: ...e all other terminals are green G trip around 10 mm 0 4 of insulation from the wire avoid fraying Ferrules are su Remove the upper part of the terminals for an easy cabling Insert wire tip or ferrule...

Страница 10: ...Diagram 3 00 C IP68 or F3 01 C compact version F3 00 C IP65 flow sensor connection LFXX R flow sensor connection Maximum cable length is 16 m 52 8 ft F flow sensor connection U F9 20 Battery Powered F...

Страница 11: ...rn to View Menu Scroll gh Scroll through Enter menu it Return to Menu Edit Modify an item Modify an item fla ts Return to Menu Save new 5 2 General Operation Flowchart The F9 20 battery powered flow m...

Страница 12: ...F9 20 Battery Powered Flow Monitor 12...

Страница 13: ...u will need to enter the password first Lock or unlock the total reset in Option Menu refer to section 8 4 8 Restot PWD for details 7 Menu Directory Level Access to this level can be free or password...

Страница 14: ...7 1 Free access no password required 7 2 Password protected access F9 20 Battery Powered Flow Monitor 14...

Страница 15: ...tant flow rate and the total flow rate All the options available are displayed on the LCD The instrument will automatically convert the values of the two totalizers in the new engineering units To set...

Страница 16: ...and material Refer to section 10 K Factor Tables for the correct v Limits 000 01 to 99999 the K Factor cannot be set to 0 8 1 3 Inftot Backup The totalizer value can be stored in permanent memory whe...

Страница 17: ...the averaging level of LCD output and relay response To set the flow rate decimal point position To set the totalizer decimal point position To set ON or OFF password protection to enter Menu Levels...

Страница 18: ...sition to get the best resolution for the application Select one of the following options XXXXXXXX XX S position to get the best solution for the re a Select one of the llowing optio fo X X X XX XX XX...

Страница 19: ...odified Se pro tot undesired res OTE the standard password is and it cannot be modified ON the Menu PWD to tect access to Menu ectory Level and next els 2 5 Restot PWD 8 t ON the Restot PWD to tect th...

Страница 20: ...a valve F9 2 the s When the tank is full switch off the pump or close the valve Press ENTER to stop calculation F9 20 stops counting pulses from the sensor Enter the volume in liter of fluid filled i...

Страница 21: ...heck sensor connection If n verify sensor data sheet and compatibility K Factor cannot be set to 0 Volume filled into the tank during K factor calculation procedure cannot be set to 0 Enter K Factor v...

Страница 22: ...iron Other metals 51 57 48 94 51 37 50 4 10 2 K Factor values f saddles on PN 10 plastic pipes Dimensions K Factors D mm DN mm PVC PP PVDF PE AD 63 50 21 95 27 25 20 11 27 50 75 65 16 90 18 71 13 83...

Страница 23: ...Field M Flow Moni ransmitter L0 EPDM F9 0 Field M Flow Moni ransmitter L0 FPM F9 0 Field M Flow Moni ransmitter L1 EPDM F9 00 04 Field Mount Flow Monitor Transmitter L1 CPVC FPM F9 00 05 Field Mount F...

Страница 24: ...Kit Plastic adapter with gasket compact cap locking ring and 4 fixing screws F9 KP1 Panel mounting Kit Mounting bracket with gasket F9 KW1 Wall mounting Kit Plastic adapter with gasket and fixing scr...

Страница 25: ...all PG 1 mounting Kit 2 F9 2 PG 11 PG11 Cable Gland for Compact or Wall mounting Kit 3 F9 SP6 battery 3 6 Volt Lithium thionyl chloride battery Replacement SP4 F I P Formatura Iniezione Polimeri S p A...

Отзывы: