3.3 

Application limits

 

The materials of construction of a Shearstream SB Ball Valve are specified in the Shearstream SB Ball Valve datasheet. 

It is especially important that the designer of the SIF checks for material compatibility considering on-site chemical 

contaminants and air/hydraulic (as appropriate) supply conditions. If the Shearstream SB Ball Valve is used outside the 

application limits or with incompatible materials, the reliability data and predicted SIL capability becomes invalid.

3.4 

Design Verification

 

A detailed Failure Modes, Effects and Diagnostics Analysis (FMEDA) report is available from NAF AB for this product. This 

report details all failure rates and failure modes as well as expected lifetime of the product.

 

The achieved Safety Integrity Level (SIL) of an entire Safety Instrumented Function (SIF) design must be verified by 

the designer via a calculation of PFDAVG considering the architecture, proof test interval, proof test effectiveness, 

any  automatic diagnostics, average repair time and the specific failures rates of all equipment included in the SIF. Each           

subsystem must be checked to assure compliance with minimum Hardware Fault Tolerance (HFT) requirements. The   

exida exSILentia™ tool is recommended for this purpose as it contains accurate models for the Shearstream SB Ball 

Valve and its failure rates.

 

When using the Shearstream SB Ball Valve in a redundant configuration, a common cause factor of at least 5% should be 

included in the safety integrity calculations.

 

The failure rate data listed in the FMEDA report is only valid for the useful lifetime of the Shearstream SB Ball Valve. The 

failure rates will increase after this useful lifetime period has expired. Reliability calculations based on the data listed in 

the FMEDA report for mission times beyond the lifetime may yield results that are too optimistic, i.e. the calculated SIL 

will not be achieved.

3.5 

SIL Capability

 

3.5.1  Systematic Integrity

 

The Shearstream SB Ball Valve has met manufacturer design process requirements of Safety Integrity Level (SIL) 3. 

These are intended to achieve sufficient integrity against systematic errors of design by the manufacturer. A Safety              

Instrumented Function (SIF) designed with this product must not be used at a SIL higher than the statement without 

“prior use” justification by the end user, or verification of diverse technology in the design. 

3.5.2  Random Integrity

 

According to IEC 61508 the architectural constraints of an element must be determined. This can be done by following  

the 1H approach according to 7.4.4.2 of IEC 61508 or the 2H approach according to 7.4.4.3 of IEC 61508. 

 

The 1H approach involves calculating the SFF for the entire element.

 

The 2H approach involves assessment of the reliability data for the entire element according to 7.4.4.3.3 of IEC 61508.

 

The Shearstream SB Valve is classified as a device that is part of a Type A element according to IEC 61508, having a hardware 

fault tolerance of 0.

 

The Shearstream SB Valve can be classified as a 2H device when the failure rates listed in the FMEDA report are used for 

the Design Verification calculations. When 2H data is used for all of the devices in an element, then the element meets the 

hardware architectural constraints up to SIL 2 at HFT=0 (or SIL 3 @ HFT=1) per Route 2H. If Route 2H is not applicable 

for the entire final element, the architectural constraints will need to be evaluated per Route 1H.

 

When the final element assembly consists of several components additional to Shearstream SB Ball Valve, the SIL must 

be verified for the entire assembly using the failure rates of all components. This analysis must account for architectural 

constraints by comparing both SFF and HFT with IEC61508-2, Table 2 if following Route 1H

3.5.3  Safety Parameters

 

For detailed failure rate information refer to the FMEDA report for the Shearstream SB Ball Valve.

Содержание Valtek ShearStream

Страница 1: ...1 Valtek ShearStream SB Ball Valves VLENDS4152 00 A4 05 15 Experience In Motion SIL SAFETY MANUAL Valtek ShearStream SB Ball Valves FCD VLENDS4152 00 A4 05 15...

Страница 2: ...all Valve 4 3 1 Safety Function 4 3 2 Environmental limits 4 3 3 Application limits 4 3 4 Design Verification 5 3 5 SIL Capability 5 3 5 1 Systematic Integrity 5 3 5 2 Random Integrity 5 3 5 3 Safety...

Страница 3: ...gized and spring is extended Fail Annunciation Detected Failure that does not cause a false trip or prevent the safety function but does cause loss of an automatic diagnostic and is not detected by an...

Страница 4: ...Programmable Electronic Safety Related Systems IEC 60654 1 1993 02 second edition Industrial process measurement and control equipment Operating conditions Part 1 Climatic condition 2 Shearstream SB B...

Страница 5: ...time may yield results that are too optimistic i e the calculated SIL will not be achieved 3 5 SIL Capability 3 5 1 Systematic Integrity The Shearstream SB Ball Valve has met manufacturer design proce...

Страница 6: ...4 2 Physical location and placement The Shearstream SB Ball Valve shall be accessible with sufficient room for pneumatic connections to the actuator and shall allow for manual proof testing to take pl...

Страница 7: ...f the mechanical parts is 10 000 full scale cycles or 8 to 10 years whichever results in the shortest lifetime 5 4 Notification of failures In case of malfunction of the system or SIF the Shearstream...

Страница 8: ...derstand the Installation Operation Maintenance IOM instructions included with the product and train its employees and contractors in the safe use of Flowserve products in connection with the specific...