SVCN 7 INSTALLATION, OPERATION, & MAINTENANCE
pure mist systems, ensure that the pure mist system is installed on the pump bearing housing, and is
operating in accordance with the manufacturer’s instructions. No further preparation is necessary.
3.3.1 LUBRICATION SPECIFICATIONS
The ideal bearing lubricant is mineral oil, preferably of the turbine type. It should not contain free
acid, chlorine sulfur or more than a trace of free alkali. It is suggested that the oil conform to the
following physical characteristics. See Figure 3-4 for recommended viscosity at specified pumping
and ambient temperature.
F
ISO 32 (150 SSU)
Oiling Ring Lube
ISO 46 (220 SSU)
Oiling Ring Lube
Pure Oil Mist
ISO 46 (220 SSU)
Frame A
Pumpage
Temperature
Ambient Temperature
C
130
120
110
100
90
80
70
60
50
400
350
300
250
200
150
100
50
0
40
50
40
30
20
10
C
F
100
200
300
400
500
600
700
800
F
Pure Oil Mist ISO
68 (315 SSU)
Frame B & C
Pumpage
Temperature
ISO 68 (315 SSU)
Ambient Temperature
C
130
120
110
100
90
80
70
60
50
400
350
300
250
200
150
100
50
0
40
50
40
30
20
10
C
F
100
200
300
400
500
600
700
800
Figure 3-4 Recommended Viscosity at Specified Pumping and Ambient Temperature
Frame A
Frame B
Frame C
1×7 1.5×10.5
6×13
6×18
1.5×7 2×10.5 8×13 8×18
2×7 3×10.5S
3×15
10×18
3×7 3×10.5
4×15
6×21
1×8.5 4×10.5 6×15S
8×21
1.5×8.5 6×11
6×15LS 10×21
2×8.5 8×11 6×15L
3×8.5S 2×13
8×15
3×8.5 3×13S 10×15
4×8.5 3×13 3×17
4×13
4×17
Table 3-1 - Pump Frame by Pump Size
3.3.1.1 Synthetic Lubricants
If a synthetic lubricant (fire-resistant fluid) is to be used instead of the normal type oil for the
lubrication of bearings, gears etc., the material of all gaskets and O-rings in contact with the lubricant
must be compatible with the lubricant. Normal gasket materials will usually swell and deteriorate
when immersed in synthetic lubricants, and normal paints will peel from internal walls of reservoirs
and bearing chambers.
- 3-5 -
DO2604-13
Содержание SVCN 7
Страница 2: ...SVCN 7 PUMP INSTALLATION OPERATION MAINTENANCE 1 ...
Страница 15: ......
Страница 57: ......
Страница 60: ...SVCN 7 INSTALLATION OPERATION MAINTENANCE 5 3 DO2604 13 ...