Flowserve MaxFlo4 Скачать руководство пользователя страница 13

Table 8: Parts list

13

MaxFlo 4 Control Valve  FCD VLENIM0064-02-AQ – 09/16

flowserve.com

Item 117  Packing box nuts

Item 109  Packing box studs

Item 80 

Gland flange

Item 87 

Packing follower

Item 114  Bonnet nuts

Item 108  Bonnet studs

Item 88 

Packing set

Item 93 

Packing spacer

Item 99 

Packing stop

Item 40 

Bonnet

  

Item 58¹  Bonnet gasket

Item 46 

Thrust bearing

Item 51 

Shaft

Item 83 

Shaft bearing

Item 50

2

 Plug

Item 84 

End post bearing

Item 1  

Body

Item 20

2

 Seat

Item 30 

Seat retainer

Item 61¹  End post gasket

Item 122  End post
Item 115  End post studs
Item 119  End post nuts

Note 1: Start-up/commissioning spares
Note 2: Two-year operation spares

Note: MBT, 10% carbon filled TFE, lined metal shell

Item

Description

Material

1

Body

A216-WCC / 1.0619
A351-CF8M / 1.4408

20

Seat Ring

316L SS
316L w/ Alloy 6
416 SS HT
316L / PTFE

30

Seat Retainer

Stainless Steel

40

Bonnet

Carbon Steel 
Stainless Steel

50

Plug

1.4418
1.4405
(6”/DN 150 and larger)
316L w/ Alloy 6
CF3M w/ Alloy 6
(6”/DN 150 and larger)

51/122

Shaft / End Post

1.4418
17-4PH
17-4PH H1150D
A638 Gr 660

46/83/84 Bearings

MBT¹
440C SS HT
Ultimet
UNS S31803
Alloy 6

58/61

Gaskets

PTFE
Graphite

80

Gland Flange

Stainless Steel

87

Packing Follower Stainless Steel

88

Packing

PTFE V-ring
Braided PTFE
LATTYflon 3265 LM
LATTYgraf 6995 NG
Graphite Braid

93/99

Packing Spacers  
& Stops

Stainless Steel

108/114

Bonnet Bolting

Carbon Steel
Stainless Steel

109/117

Gland Bolting

Stainless Steel

115/119

End Post Bolting

Carbon Steel
Stainless Steel

Figure 4: Valve reassembly

Item numbers correspond directly to the valve’s bill of material.  

Refer to it for specific part numbers.

Содержание MaxFlo4

Страница 1: ...MaxFlo 4 Eccentric Rotary Plug Control Valve FCD VLENIM0064 02 AQ 09 16 Experience In Motion USER INSTRUCTIONS Installation Operation Maintenance...

Страница 2: ...ained and qualified technicians are authorized to adjust repair or work on control valves actuators positioners and other accessories Review this bulletin prior to installing operating or performing a...

Страница 3: ...p to 300 g m3 unless restricted by the accessories The product offering may include optional ancillary equip ment such as positioners air filter regulators solenoid valves limit switches or boosters D...

Страница 4: ...her dirt and other potentially harmful influences Do not remove the protective covers from the body flanges of the control valve or from the instrument ports of the actuator and accessories until the...

Страница 5: ...hure for proper clearances 6 Confirm there are suitable piping lengths upstream and downstream of the valve installation site in order to minimize a sudden pressure surge in the flow Absence of suitab...

Страница 6: ...cause leakage in PTFE and graphite gaskets Consult a current chemical resis tance list before applying 2 Whenever possible the valve should be installed so that actuator is in an upright position Vert...

Страница 7: ...bient temperature par ticle size below 1 m and oil content not to exceed 1 ppm Contaminated instrument air can damage the accessories and control valve or cause them to fail 4 Do not touch the body an...

Страница 8: ...ft cloth Overhaul or replace actuator after prod uct lifecycle 5 Preventive overhaul of the valve Dependent upon results of previous maintenance see numbers 1 to 4 above or a minimum once every 60 mon...

Страница 9: ...larm Table 4 continued Service activities checklist Prior to valve maintenance we require that you check the following conditions to reduce the risk of malfunction and safety related incidents No Chec...

Страница 10: ...ure usually 87 psig 6 bar 1 2 Mounted accessories do not work See User Instructions for accessory manufacturer 1 3 Pneumatic actuator is defective Contact customer service department or contract partn...

Страница 11: ...plug Contact customer service department or contract partner 4 2 Foreign particles in seat area Contact customer service department or contract partner Slightly retighten packing box NOTICE Make sure...

Страница 12: ...nterna tional environmental regulations for control valve removal from the pipe and cleaning Permissible exposure limits must be maintained appropriate personal protective equip ment must be used and...

Страница 13: ...ion Material 1 Body A216 WCC 1 0619 A351 CF8M 1 4408 20 Seat Ring 316L SS 316L w Alloy 6 416 SS HT 316L PTFE 30 Seat Retainer Stainless Steel 40 Bonnet Carbon Steel Stainless Steel 50 Plug 1 4418 1 44...

Страница 14: ...ste Molydal NB1200 or a nickel anti seize lubricant Permatex 77164 or equivalent Place the valve body in a vice and clamp securely in a vertical position 13 12 Always use new packing and gaskets when...

Страница 15: ...t lbs 210 Nm 3 DN 80 Part number 183227 999 000 Torque 406 ft lbs 550 Nm 4 DN 100 Part number 183228 999 000 Torque 428 ft lbs 580 Nm 6 DN 150 Part number 183229 999 000 Torque 959 ft lbs 1300 Nm 8 DN...

Страница 16: ...roducts should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions Although Flowserve can and often does provide general guide...

Отзывы: