147
Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08
flowserve.com
STEP 9
Mount new power assembly (1-19) on top of the three standoffs (1-55) using the existing three M4
power assembly screws (1-45).
a
CAUTION:
Assure the voltage jumper on the power board is located in the proper location
per the nameplate and motor voltage! See Figure 5.8 for location of jumper.
STEP 10
Route the two-pin AMP plugs (L1 power connector) over the bottom plate of the control module
and connect to the ceramic fuse block plug.
NOTE:
1-53 SSMR protection fuse Limitorque part number 102476, Bussmann part number
FWP-30A14F.
STEP 11
Referring to Section 5.2.2, connect all plugs.
STEP 12
Mount the CP cover assembly per Section 5.1. Applicable wiring diagrams: 1792, 1793, 1794,
1795, 1796, and 1797.
5.19 Mounting of SSMR (Solid State Motor
Reverser) in units shipped after February 2008
Table 5.19 - SSMR Parts List
Part Number
Description
Qty.
1-18
Controls cover assembly
1
7-27
Socket head cap screws
4
1-52
Solid state reverser power assembly
1
1-55
Standoff
3
Swanson Flo | 800-288-7926 | www.swansonflo.com
Содержание Limitorque MX-05
Страница 2: ...Swanson Flo 800 288 7926 www swansonflo com ...