Adjusting the stroke limiter
The further you screw in the hexagon bolt, the more
the flowrate is reduced.
13
To restrict the stroke length screw the hexagon
bolt (15) in a clockwise direction.
To increase the stroke length screw the
hexagon bolt (15) in an anticlockwise direction.
15
To lock the stroke limiter in place, screw down
the nut until it hits the handwheel nut.
Operation
Activities during operation
CAUTION
Hot surfaces and heat radiation present
the risk of burns.
Wear protective gear that is suitable
for the temperatures generated in your
plant.
Do not work on the equipment while it is operating.
After operation
DANGER
If the equipment is used in contaminated
areas there is a risk of severe injuries or
death caused by harmful substances in or
on the equipment.
Only qualified personnel are allowed to
perform work on contaminated
equipment.
Always wear the protective clothing
prescribed for contaminated areas
when working on the equipment.
Make sure that the equipment is
completely decontaminated before
carrying out any service work.
Follow the pertinent instructions for
handling the hazardous substances in
question.
Attention!
Frost damage may occur when the
installation is shut down.
Drain the equipment if ambient
temperatures below 0 °C (frost) are to
be expected.