DURCO MARK 3 ISO FRAME MOUNTED ENGLISH 85392719 06-12
Page 34 of 52
flowserve.com
Impeller assembly with key drive
6.10.4.2
impeller
a) Fit a new impeller sealing gasket [4590.4] against
shaft shoulder.
b) Fit impeller key [6700.2].
c) Assemble impeller [2200] onto the shaft [2100].
d) Fit a new O-ring [4610.5] into the impeller nut
[2912.1/2912.2] groove.
e) Apply anti-galling compound (which does not
contain copper) to the impeller nut threads to
help any subsequent removal.
f) Fit impeller nut [2912.1/2] onto the shaft [2100]
and torque up.
6.10.5 Assembly of power-end into casing
a) Fit a new gasket [4590] into the casing [1100].
On the recessed impeller a new gasket
is required each side of the distance ring [2510.2].
b) Ensure bearing housing and adaptor concentricity
and squareness.
c) Install the power-end assembly into the pump
casing. Coat the studs [6572.1] with anti-galling
compound and tighten nuts [6580.1] onto casing.
d) Check impeller clearance against original setting
or process requirement and adjust as necessary.
(See section 6.7, Setting impeller clearance.)
e) Ensure that all other items have been re-attached
and all fasteners tightened to the correct torques,
then follow the instructions in the sections on
Installation and Commissioning.
6.11 Sealing arrangements
The following section shows details of the seal
arrangements. The dimensions provided are for non-
step balanced mechanical seals conforming to EN
12757 L1K and L1N. Contact your nearest Flowserve
sales office or service centre if you require further
information, such as a mechanical seal dimensional
drawing, or are unsure of the specific arrangement
supplied. Refer also to section 4.6.5, Auxiliary piping.
6.11.1 Single seal types
Single stepped balanced seal
6.11.1.1
Single unbalanced (or inherently
6.11.1.2
balanced) seal
Bearing housing
Setting dimension mm (in.)
X
Y
Frame 1
23.5 (0.925)
11.0 (0.433)
Frame 2
34.0 (1.339)
19.0 (0.748)
Frame 3
33.5 (1.319)
11.0 (0.433)
Frame 4
51.5 (2.028)
24.0 (0.945)
Single seal with external neck bush
6.11.1.3
Q - Rp ¼ in. quench
D - Rp ¼ in. drain
F - Rp ¼ in. flush
Bearing housing
Setting dimension mm (in.)
X
Y
Frame 1
23.5 (0.925)
11.0 (0.433)
Frame 2
34.0 (1.339)
19.0 (0.748)
Frame 3
33.5 (1.319)
11.0 (0.433)
Frame 4
51.5 (2.028)
24.0 (0.945)