Flowserve ColdFlow 341000 Скачать руководство пользователя страница 14

14

Kämmer Series 341000  FCD KMENIM4104-01 03/18

7.1  Cv Table

Kvs

Cv

Seat 

Trim#

4

6

8

10

15

20

25

32

40

50

65

80 100 125 150 200

0.16˝ 0.25˝ 0.31˝ 0.39˝ 0.59˝ 0.79˝ 1˝ 1.25˝ 1.5˝ 2˝ 2.5˝ 3˝

mm

in

mm

10

20

40

60

0,011

0,013

3

0.12H 3H

0,017

0,02

0.12G 3G

0,025

0,029

0.12F 3F

0,04

0,047

0.12E 3E

0,063

0,074

0.12D 3D

0,1

0,12

0.12C 3C

0,16

0,19

0.12B 3B

0,25

0,29

0.12A 3A

0,4

0,47

4,5

0.18B 4.5B

0,63

0,74

0.18A 4,5A

1

1,2

7

0.28B 7B

1,6

1,9

0.28A 7A

10

0.40B 10B

2,5

2,9

0.40A 10A

4

4,7

15

0.63B 15B

6,3

7,4

0.63A 15A

20

0.80B 20B

10

12

0.80A 20A

25

1.00B 25B

16

19

1.00A 25A

32

1.25B 32B

25

29

1.25A 32A

40

1.60B 40B

40

47

1.60A 40A

50

2.00B 50B

63

74

2.00A 50A

63

2.50B 63B

100

120

2.50A 63A

80

3.20B 80B

160

190

3.20A 80A

100

3.90B 100B

250

290

3.90A 100A

125

4.90B 125B

400

470

4.90A 125A

140

5.50B 140B

560

650

5.50A 140A

190

7.48B 190B

900

1040

7.48A 190A

* Alloy 6 plug only / equal percentage characteristic only

TECHNICAL TABLES

Содержание ColdFlow 341000

Страница 1: ...1 K mmer Series 341000 FCD KMENIM4104 01 03 18 Experience In Motion Maintenance USER INSTRUCTIONS ColdFlow 341000 Cryogenic Control Valves 4K FCD KMENIM4104 01 03 18...

Страница 2: ...r substantial property damage will occur if proper precautions are not taken STOP WARNING indicates that death severe personal injury and or substantial property damage can occur if proper precautions...

Страница 3: ...is shown on a stainless steel nameplate attached to the actuator See also section 5 Identification 2 2 Preparation for vacuum box installation figure 2 2 2 1 After trim has been removed from the valve...

Страница 4: ...form a pressure test with all valves For this all valves must be fitted with mounting flanges This mounting flange has a dual purpose firstly it assists in mounting the valves into the vacuum tank and...

Страница 5: ...he trim assembly with the valve housing Severe damage of the bellows seal and or the trim assembly may occur 3 2 Install Trim assembly Figure 8 3 2 1 Insert body O Ring seal 8 1 3 2 2 Carefully insert...

Страница 6: ...plug 11 3 All three components can be disassembled and replaced individually These parts are secured with pins 11 4 To remove the pins carefully drive them out by a suitable tool When replacing one o...

Страница 7: ...l Number of the valve engraved at the bonnet and of the actuator Tag plate correspond to each other 4 1 2 Removing for repair or maintenance figure 13 We recommend separating the actuator from the val...

Страница 8: ...d ensuring the actuator faces in the right direction 4 1 3 3 Unscrew the coupling insert until the lower yoke rods are raised from the lower yoke plate by around 2 mm NOTE Ensure that the plug assembl...

Страница 9: ...l repair work However many maintenance and adjusting operations can be carried out in an installed condition 4 2 2 1 Shut off air supply 4 2 2 2 Disconnect all air tubing from the actuator 4 2 2 3 Rem...

Страница 10: ...the plug stem to ensure the plug is fully seated 4 2 3 1 Using suitable lifting equipement carefully place the actuator onto the valve assembly Before the actuator is fully lowered slip the locknut on...

Страница 11: ...lve assembly valve plus actuator are clearly marked with the serial number CAUTION Ensure that only parts of the same serial number are assembled together Serious damage of the parts may occur Figure...

Страница 12: ...70 S46031147 ID 33 4 x 2 4 4 0 16 6 0 25 8 0 31 10 0 39 2 70 0100376A2 15 0 59 20 0 79 25 1 70 341B50471 00 2 70 0100380A2 70 S46031165 ID 59 92 x 2 62 32 1 25 40 1 5 50 2 65 2 5 70 341K80271 00 1 70...

Страница 13: ...419435XCT 70 3419465XCT 20 0 79 6 3 7 4 20B 0 80B 70 3419435VCT 70 3419465VCT 10 12 20A 0 80A 70 3419436VCT 70 3419466VCT 25 1 10 12 25B 1 00B 70 3419436ECT 70 3419466ECT 16 19 25A 1 00A 70 3419437ECT...

Страница 14: ...0 4 0 47 4 5 0 18B 4 5B 0 63 0 74 0 18A 4 5A 1 1 2 7 0 28B 7B 1 6 1 9 0 28A 7A 10 0 40B 10B 2 5 2 9 0 40A 10A 4 4 7 15 0 63B 15B 6 3 7 4 0 63A 15A 20 0 80B 20B 10 12 0 80A 20A 25 1 00B 25B 16 19 1 00...

Страница 15: ...2 5 3 40 1 5 85 65 875 48 120 48 3 x 2 7 1 50 2 85 62 875 48 120 60 3 x 2 7 1 65 2 5 125 105 875 57 190 76 1 x 2 6 30 80 3 125 105 875 57 190 88 9 x 3 05 30 100 4 175 125 1000 59 230 114 x 3 53 125 5...

Страница 16: ...675 daN 1000 daN 1500 daN 3900 daN 6000 daN 4 0 16 10 0 394 X X X 6 0 25 10 0 394 X X X 8 0 31 10 0 394 X X X X 10 0 38 10 0 394 X X X X 15 0 5 10 0 394 X X X X 20 0 75 10 0 394 X X X X 25 1 20 0 787...

Страница 17: ...damaged 3 Renew gaskets 4 Inadequate actuator thrust 4 Check air feed If air feed is OK contact Flowserve 5 Plug incorrectly adjusted 5 Correctly adjust plug according to step 3 3 1 6 Incorrect direc...

Страница 18: ...18 K mmer Series 341000 FCD KMENIM4104 01 03 18 Notes...

Страница 19: ...19 K mmer Series 341000 FCD KMENIM4104 01 03 18 Notes...

Страница 20: ...gen vorbehalten All data subject to change without notice 04 2017 Flowserve Corporation Flowserve and K mmer are registered trademarks of Flowserve Corporation Your contact Flowserve Essen GmbH Schede...