![Flowmeter SVTU-11B Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/flowmeter/svtu-11b/svtu-11b_operating-manual_2308318045.webp)
45
14
Storing
14.1
Water meter storing can be made in heated or unheated storehouses.
Meter life cycle:
−
in heated storehouse is no more than 10 years;
−
in unheated storehouse is no more than 5 years.
14.2
Storage conditions for meters:
1)
in heated storehouse:
−
ambient temperature can vary from 0 up to 50
°
С
;
−
relative air humidity is up to 80 %, while temperature is 30
°
С
and below without
moisture condensation;
2)
in unheated storehouse:
−
ambient temperature can vary from minus 5 °C up to 50
°
С
;
−
relative air humidity is up to 95 %, while temperature is 35
°
С
and below without
moisture condensation.
14.3
At long-term storage in unheated storehouse meters should be placed in an addi-
tional cover from a polyethylene film.
15
Transportation
15.1
Meters can be transported by all modes of transport. Their packing should provide
protection against direct influence of atmospheric precipitation.
While transporting by air transport, meters in packing should be placed in hermetically
compartments.
15.2
Transportation conditions:
−
ambient temperature:
−
for calculator can vary from minus 20
°
С
up to 50
°
С
;
−
for FS can vary from minus 50
°
С
up to 70
°
С
;
−
relative air humidity is up to 98 %, while temperature is 35
°
С
;
−
transport jolty with acceleration 30 m/sec
2
, while frequency varies from 80 up to 120
beats per minute.
15.3
Meters are steady against influence of sinusoidal vibrations, while frequencies vary
from 5 up to 35 Hz with amplitude up to 0.35 mm.
15.4
Throwing of meters during delivering and unloading it is not permitted.
FS and packing box with the calculator should be fixed to except accidental moving at
shipment in vehicle.
16
Guarantee of manufacturer
16.1
Manufacturer guarantees that produced water meters meet to all requirements of
their specifications within 48 months from the moment of shipment if the consumer observes
the following conditions:
−
installation, starting-up and adjustment of the water meter is made by the organiza-
tion, which has the manufacturer’s sanction;
−
a mark of the organization, which has provided installation, starting-up and adjust-
ment of the water meter should be put in section 19 of present Operating manual;
Содержание SVTU-11B
Страница 1: ...Water meter SVTU 11B Operating manual SMP 407251 010 Part 1 September 2010...
Страница 2: ......
Страница 29: ...29 Figure 9 7 Installation of R D S of type 2 3 and 4 without thermal pocket...
Страница 30: ...30 Figure 9 8 Installation of R D S of type 2 3 and 4 with thermal pocket...
Страница 37: ...37 Figure 11 1...
Страница 40: ...40 Figure 121 1...
Страница 49: ...49 Appendix C Overall and connecting dimensions of calculator 17...
Страница 51: ...51...
Страница 52: ...52 Indication of main parameters mode...
Страница 53: ...53 Check mode...
Страница 54: ...54 Setup mode...
Страница 55: ...55 Setup Set zero mode Setup PS parameters mode...
Страница 56: ...56 Setup Pressures mode...
Страница 61: ...61 Schematic of device cable...
Страница 62: ...62 Pinout of connectors...
Страница 64: ...64 Appendix L Overall and connecting dimensions for flow measurement sections FS...
Страница 65: ...65 Overall and connecting dimensions for FS 32...
Страница 66: ...66 FS of DN 50 80 FS of DN 100 150...