14
Designation and basic parameters of FS in complete set are indicated in the table 4.2.
(For outline drawing of FS see Appendix L)
Table 4.2
FS
DN,
mm
Marking on FS
Number of places
for flow sensors
Marking
Nominal bore Nominal
pressure
Single beam flow measurement section
FS
-20
20
DN 20
PN 16
-
FS
-20
FS
-32
32
DN 32
2
FS
-32
FS
-50
50
DN 50
FS
-50
FS
-65
65
DN 65
FS
-65
FS
-80
80
DN 80
FS
-80
FS
-100
100
DN 100
FS
-100
РУ
-125
125
DN 125
FS
-125
РУ
-150
150
DN 150
FS
-150
Another componentry included in delivery set in accordance with the obligatory or ad-
ditional order are listed in the table 4.3.
4.2
Meter’s configuration, FS type, connecting cables, number of communications
channels and their length are specified while ordering. The format of meter’s marking is giv-
en in Appendix A.
Description of design features for FS and also drawings, mounting dimensions are re-
sulted in Appendix K.
Warning
!!!
Identification of FS standard size is provided by marking of nominal diameter DN on
FS body.
Thus numerical value in FS reference designation meets to a numerical value in a de-
signation of a nominal diameter DN (see table 4.2).
Example:
−
Marking “
DN 32
” put on the flow measurement section with reference designation
FS-32. Next element of marking “
Р
N 16
” means that this flow measurement section is in-
tended for use in heat- or water-supply systems with overpressure 1.6
М
P
а
(16 kgf/
с
m
2
);
Table
4.3 Componentry included in delivery set
#
Name
Marking
Assignment
Number
Set of delivery
obliga-
tory
Special
order
1
Pipe nipple
SMP.752291.001
Connection of FS-20 with
straight pipe section
2 pcs. for
1 FS
+
2
Pipe nipple
SMP.302661.002
Connection of FS -32
р
with
straight pipe section
+
3
Sleeve nut
SMP.758422.006
Mounting of FS -20
+
4
Sleeve nut
SMP.758422.001
Mounting of FS -32
+
5
Flange
SMP.711154.013-01, 013-03,
013-05 (in accordance with DN
of FS)
Mounting of FS -50…80
+
Содержание SVTU-11B
Страница 1: ...Water meter SVTU 11B Operating manual SMP 407251 010 Part 1 September 2010...
Страница 2: ......
Страница 29: ...29 Figure 9 7 Installation of R D S of type 2 3 and 4 without thermal pocket...
Страница 30: ...30 Figure 9 8 Installation of R D S of type 2 3 and 4 with thermal pocket...
Страница 37: ...37 Figure 11 1...
Страница 40: ...40 Figure 121 1...
Страница 49: ...49 Appendix C Overall and connecting dimensions of calculator 17...
Страница 51: ...51...
Страница 52: ...52 Indication of main parameters mode...
Страница 53: ...53 Check mode...
Страница 54: ...54 Setup mode...
Страница 55: ...55 Setup Set zero mode Setup PS parameters mode...
Страница 56: ...56 Setup Pressures mode...
Страница 61: ...61 Schematic of device cable...
Страница 62: ...62 Pinout of connectors...
Страница 64: ...64 Appendix L Overall and connecting dimensions for flow measurement sections FS...
Страница 65: ...65 Overall and connecting dimensions for FS 32...
Страница 66: ...66 FS of DN 50 80 FS of DN 100 150...