Flow vision FS10-dbEX Скачать руководство пользователя страница 5

G

MB

H

FS10-dbEX

 | Flow Monitor

5

 DESCRIPTION

G

t

L

t

SW

ød

27

32

40

50

55

70

SW

50

64

78

94

110

138

11

12

14

15

15

19

t

ød

16

20

25

32

40

50

DN

Typ/Type

TP-01 …

TP-02 …

TP-03 …

TP-04 …

TP-05 …

TP-06 …

15

20

25

32

40

50

G

1/2"

27

50

10

8

TP-00 … 8

1/4"

3/4"

1"

11/4"

11/2"

2"

L

Arretierstift

retention pin

Sensoradapter TP-…  / Sensor adapter TP-…:

Kugelhahn BV-… / Ball valve BV-…:

41

50

54

70

SW

88

100

110

131

21

24

24

28

t

ød

25

32

40

50

DN

Typ/Type
BV-03M3

BV-04M3

BV-05M3

BV-06M3

25

32

40

50

G

1"

11/4"

11/2"

2"

L

59

65

77

85

H

115

115

150

150

A

H

ød

G

t

SW

A

L

ø18

18.2

ø23.8

Anschweißset 05/

welding set 05 :

4

Anschweißstutzen / welded fitting

Edelstahl 1.4571 /stainless steel 1.4571/AISI 316 Ti

Arretierstift / retention pin

Überwurfmutter / cap nut

Edelstahl 1.4571/stainless steel 1.4571/AISI 316 Ti

PN 315 bar/4569 psi

Messing/brass

PN 25 bar / 363 psi

Rotguss  (nur TP-03..) / red brass  (only TP-03..)

PN 16 bar / 232 psi

Messing vernickelt/nickel plated brass

PN 25 bar / 363 psi

Typ/Type

ød

t

t

L

SW

øD

DN

15

20

25

32

40

50

27

32

40

50

55

70

SW

80

70

80

100

110

140

15

15

15

15

15

15

t

ød

16

20

25

32

40

50

TP-01M1-SA

TP-02M1-SA

TP-03M1-SA

TP-04M1-SA

TP-05M1-SA

TP-06M1-SA

L

øD

21.3

8

27

80

15

8

TP-00M1-SA

13.5

26.9

33.7

42.4

48.3

60.3

Edelstahl 1.4571/stainless steel 1.4571/AISI 316 Ti

PN 315 bar/4569 psi

G

MB

H

G

MB

H

G

MB

H

Fig. 2

Содержание FS10-dbEX

Страница 1: ...Str mungsw chter FS10 dbEX MONTAGE UND EINSTELLANLEITUNG Flow Monitor FS10 dbEX INSTRUCTIONS FOR INSTALLATION AND ADJUSTMENT M_FS10 dbEX_0320_d_e...

Страница 2: ...chritts jederzeit zu ndern Ma nderungen sind vorbehalten nderungen sowie auch Irrt mer und Druckfehler vorbehalten Equipment installation connection and adjustment by qualified personnel only Please f...

Страница 3: ...ub in Abh ngigkeit von der maximalen Mediums temperatur siehe Tabelle 1 Ex atmosphere Information on explosion protection The flow monitor FS10 dbEX has been designed for use in potentially explosive...

Страница 4: ...rretierungsnut Locking slot berwurfmutter 3 4 Cap nut 3 4 O Ring 15 3x2 2 in Anlehnung an DIN ISO 6149 Material FKM O Ring 15 3x2 2 following DIN ISO 6149 material FKM SW 27 SW 30 120 70 36 120 70 36...

Страница 5: ...Anschwei set 05 welding set 05 4 Anschwei stutzen welded fitting Edelstahl 1 4571 stainless steel 1 4571 AISI 316 Ti Arretierstift retention pin berwurfmutter cap nut Edelstahl 1 4571 stainless steel...

Страница 6: ...500 mA induktive Last max 100 mA Kennzeichnung gem den Bestimmun gen der Richtlinien 2014 30 EU EMV und 2014 34 EU ATEX 3 Technical Data Flow rate range liquids 10 mm s 0 39 inch s minimum 4 5 m s 14...

Страница 7: ...be a distance of at least 10 pipe dia meters before the flow monitor and 5 pipe diameters after the flow monitor before or after any bends and changes in pipe dia meter to avoid any effects of turbul...

Страница 8: ...der berwurfmutter durch den Arretierstift garantiert c For horizontal pipelines the flow monitor should be mounted on the underside of the line suspended d Avoid installing the flow monitor in known...

Страница 9: ...ition of the sensor is ensured retention pin locking slot Exakte Positionierung des Sensors ist sichergestellt Arretierungsstift Nut Correct position of the sensor is ensured retention pin locking slo...

Страница 10: ...age rating shown on the system Connect the cable according to the connection diagram see fig 6 and connect power supply The green LED status indication lights Achtung Die beiden Messf hler S m ssen ne...

Страница 11: ...gehen Schaltpunkt mehrmals ansteuern 5 Metall Frontdeckel aufschrauben anschlie end Gewindestift festziehen Arretierung des Metall Frontdeckels 6 Adjustment of flow response value Requirement Ensure f...

Страница 12: ...the flow monitor is suitable for the medium 7 Wartung Der Str mungsw chter ist wartungsfrei bei Me dien die sich nicht an den Messf hlern festsetzen Die Messf hler in entsprechenden Erfahrungs interva...

Отзывы: