background image

Warranty

5

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

ATTACH ORIGINAL RECEIPT HERE FOR WARRANTY CONSIDERATION.

FLOTEC warrants to the original consumer purchaser (“Purchaser”) of its products that they are free from defects in
material or workmanship.

If within twelve (12) months from the date of the original consumer purchase any such product shall prove to be defec-
tive, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and conditions set forth below. Your origi-
nal receipt of purchase is required to determine warranty eligibility.

Exceptions to the Twelve (12) Month Warranty

Product

Warranty Period

Drill Pump, Pitcher Pump,

90 days

In-line Water Filter Cartridge

1/3 HP Submersible Sump Pumps
I

NTELLI

P

UMP

(Model FP0S1775A)

2 Years

Back-up Sump Pump System (Model FP2800DCC)

4" Submersible Well Pumps
1/2 HP Submersible Sump Pumps

3 Years

Models FPSC2200A-10 and FPSC2250A-10

Pre-Charge Water System Tank

5 Years

Models FPSC3200A-10 and FPSC3250A-10

Floodmate

®

7000 (Model FP0S6000A)

Ironmate

®

(Model FPSC4550A)

Sewage Ejector (Model FPSE3601A)

Lifetime

Pedestal Sump Pump (Model FPPSS5000)
Utility Pump (Model FPSC1725X)
Submersible Sump Pump (Model FPSC4550A-10)

General Terms and Conditions

Purchaser must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty
shall not apply to acts of God, nor shall it apply to products which, in the sole judgement of FLOTEC, have been subject
to negligence, abuse, accident, misapplication, tampering, alteration; nor due to improper installation, operation, mainte-
nance or storage; nor to other than normal application, use or service, including but not limited to, operational failures
caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended
maximums.

Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to
FLOTEC as soon as possible after the discovery of any alleged defect. FLOTEC will subsequently take corrective action
as promptly as reasonably possible. No requests for service under this warranty will be accepted if received more than
30 days after the term of the warranty.

This warranty sets forth FLOTEC’s sole obligation and purchaser’s exclusive remedy for defective products.

FLOTEC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHAT-
SOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES.
IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICA-
BLE EXPRESS WARRANTIES PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long
an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific
legal rights and you may also have other rights which vary from state to state.

FLOTEC • P.O. Box 342 • Delavan, WI U.S.A. 53115

Phone: 1-800-365-6832 • Fax: 1-800-526-3757

E-Mail: [email protected] • Web Site: http://www.flotecwater.com

Содержание IntelliPump FP0S1775A

Страница 1: ......

Страница 2: ...es 2 5 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 6 9 Instalaci n Operaci n Piezas...

Страница 3: ...most recent National Electrical Code NEC and Occupational Safety and Health Act OSHA Pump motor is equipped with an auto matic resetting thermal protector and may restart unexpectedly 12 Risk of elect...

Страница 4: ...IPUMPTM is fully automatic in operation The smart controller starts the pump every 2 1 2 minutes and causes it to run for 5 seconds If it senses that there is no water to the pump it stops If it sense...

Страница 5: ...CORRECTIVE ACTION Pump won t Blown fuse If blown replace with fuse of proper size start or run Low line voltage If voltage under recommended minimum check size of wiring from main switch on property...

Страница 6: ...misapplication tampering alteration nor due to improper installation operation mainte nance or storage nor to other than normal application use or service including but not limited to operational fai...

Страница 7: ...l atelier avec des cadenas et des interrupteurs ma tres et en tant les cl s de d marrage 11 Pendant le c blage d une pompe fonctionnement lectrique suivre tous les codes de s curit et d lectricit ains...

Страница 8: ...contr leur d tecte de l eau il continuera de faire fonctionner la pompe jusqu ce que l eau soit pomp e jusqu une profondeur de 1 4 de pouce puis il arr tera la pompe La pompe passe ensuite dans un cyc...

Страница 9: ...t Le moteur est d fectueux Remplacer la pompe Roue h lice D poser la cr pine et localiser la source du coincement La pompe La tension est faible N utiliser que des cordons prolongateurs de calibre 14...

Страница 10: ...ui n ont pas t install s utilis s entrepos s ou entretenus correctement ni ceux qui n ont pas t utilis s ou entretenus normalement y compris mais sans s y limiter aux produits ayant des pan nes de fon...

Страница 11: ...ando conecte una bomba de impulsi n el ctrica respete todos los c digos el ctricos y de seguridad as como otros m s recientes como el C digo El ctrico Nacional NEC y la Ley de Seguridad e Higiene en e...

Страница 12: ...nde la bomba cada 2 1 2 minutos y hace que marche por 5 segundos Si detecta que no hay flujo de agua hacia la bomba se detiene Si detecta agua contin a funcionando hasta que haya bombeado agua hasta u...

Страница 13: ...bien consulte con la compa a el ctrica Motor defectuoso Reemplace la bomba Impulsor Retire la criba ubique la fuente del atascamiento La bomba Bajo voltaje de l nea Use nicamente cables de extensi n...

Страница 14: ...iones contraindicadas mane jo indebido alteraciones ni debido a instalaci n funcionamiento mantenimiento o almacenaje incorrectos ni a ningu na otra cosa que no sea su aplicaci n uso o servicio normal...

Страница 15: ...14 For parts or assistance call Flotec Customer Service at 1 800 365 6832...

Страница 16: ...15 For parts or assistance call Flotec Customer Service at 1 800 365 6832...

Страница 17: ......