Safety

2

Im portant  Safety 

Instructions

SAVE THESE INSTRUCTIONS - This manual contains 

important instructions that should be followed during 

installation, operation, and maintenance of the product.

This is the safety alert symbol. When you see this 

symbol on your pump or in this manual, look for 

one of the following signal words and be alert to the 

potential for personal injury!

indicates a hazard which, if not avoided, 

will result in death or serious injury.

indicates a hazard which, if not avoided, 

could result in death or serious injury.

indicates a hazard which, if not avoided, 

could result in minor or moderate injury.
NOTICE addresses practices not related to 

personal injury.
Carefully read and follow all safety instructions in this 

manual and on pump.
Keep safety labels in good condition. Replace missing 

or damaged safety labels.
California Proposition 65 Warning

This product contains chemicals known to 

the State of California to cause cancer or birth defects 

or other reproductive harm.
1. Know the pump application, limitations, and potential

hazards.

2.  Do not use in water with fish present. If any oil leaks

out of the motor it can kill fish.

3. Disconnect power before servicing.
4.  Release all pressure within system before servicing

any component.

5.  Drain all water from system before servicing.
6. Secure discharge line before starting pump. An

unsecured discharge line will whip, possibly causing

personal injury and/or property damage.

7. Check hoses for weak or worn condition before each

use, making certain that all connections are secure.

8. Periodically inspect sump, pump and system

components. Keep free of debris and foreign objects.

Perform routine maintenance as required.

9. Provide means of pressure relief for pumps whose

discharge line can be shut-off or obstructed.

10. Personal Safety:

a. Wear safety glasses at all times when working with

pumps.

b.  Keep work area clean, uncluttered and properly

lighted – replace all unused tools and equipment.

c. Keep visitors at a safe distance from work area.
d.  Make workshop child-proof – with padlocks, master

switches, and by removing starter keys.

11. When wiring an electrically driven pump, follow all

electrical and safety codes that apply.

12. This equipment is only for use on 115 volt

(single phase) and is equipped with an approved

3-conductor cord and 3-prong, grounding-type plug.

Risk of electric shock. Can shock, burn or 

kill. This pump has not been investigated for use in 

swimming pool areas. Pump is supplied with a grounding 

conductor and grounding-type attachment plug. Be sure it 

is connected only to a properly grounded grounding-type 

receptacle.
Where a 2-prong wall receptacle is encountered, it must 

be replaced with properly grounded 3-prong receptacle 

installed in accordance with codes and ordinances that 

apply.
13. All wiring should be performed by a qualified

electrician.

14. Make certain power source conforms to requirements

of your equipment.

15. Protect electrical cord from sharp objects, hot

surfaces, oil, and chemicals. Avoid kinking cord.

Replace or repair damaged or worn cords

immediately.

16.  Do not touch an operating motor. Modern motors can

operate at high temperatures.

17.  Do not handle pump or pump motor with wet hands

or when standing on wet or damp surface, or in water.

Risk of electric shock. Can shock, burn or 

kill. If your basement has water or moisture on floor, do 

not walk on wet area until all power has been turned off. 

If shut-off box is in basement, call electric company or 

hydro authority to shut-off service to house, or call your 

local fire department for instructions. Remove pump and 

repair or re place. Failure to follow this warning can result 

in fatal electrical shock.
Do not lift pump by power cord.

GPH (LPH) at total feet (m) of lift

Series

HP

(1.5m)

10 

(3m)

15 

(4.6m)

20 

(6.1m)

No flow 

at height 

shown 

below

Capacity Gallons(L)/Hour

FPZS25T  1/4

2700 

(10221)

2160 

(8176)

1500 

(5678)

-

20 ft 

(6.1m)

FPZS33T

 1/3

3060 

(11583)

2400 

(9085)

1680 

(6359)

660 

(2498)

22 ft 

(6.7m)

FPZS33V

FPZS50T

 1/2

3660 

(13855)

3000 

(11356)

2160 

(8176)

960 

(3634)

22 ft 

(6.7m)

FPZS50V

FPZS75V  3/4

4200 

(15899)

3540 

(13400)

2820 

(10675)

1800 

(6814)

24 ft 

(7.3m)

Series

HP

Motor 

Full 

Load 

Amps

Branch 

Circuit Req. 

(Amps)

Switch Setting in inches 

(cm)

On

Off

FPZS25T 1/4

3.9

15

14 (35.6)

5 (12.7)

FPZS33T 1/3

4.0

14 (35.6)

5 (12.7)

FPZS33V 1/3

4.0

7.5 (19.1)

3 (7.6)

FPZS50T 1/2

4.1

14 (35.6)

5 (12.7)

FPZS50V 1/2

4.1

7.5 (19.1)

3 (7.6)

FPZS75V 3/4

5.5

7.5 (19.1)

3 (7.6)

Performance

Electrical & Switch Specifications

Содержание FPZS25T

Страница 1: ...OWNER S MANUAL Submersible Plastic Sump Pumps Installation Operation Parts English Pages 2 7 FPZS25T FPZS33T FPZS50T FPZS33V FPZS50V FPZS75V ...

Страница 2: ...wiring an electrically driven pump follow all electrical and safety codes that apply 12 This equipment is only for use on 115 volt single phase and is equipped with an approved 3 conductor cord and 3 prong grounding type plug Risk of electric shock Can shock burn or kill This pump has not been investigated for use in swimming pool areas Pump is supplied with a grounding conductor and grounding typ...

Страница 3: ...pit of small stones and gravel which could clog pump Keep pump inlet screen clear NOTICE Do not use ordinary pipe joint compound on plastic pipe Pipe joint compound can weaken plastics Specifications Installation 3 Specifications Power supply required 115V 60 HZ Liquid Temp Range 32 F to 70 F 0 21 C Individual Branch Circuit Required min 15 Amps Discharge 1 1 2 NPT NOTICE Do not reduce size of dis...

Страница 4: ... a minimum 15 amp individual branch circuit Both pump and switch are supplied with 3 wire cord sets with grounding type plugs Switch plug is inserted directly into outlet and pump plug inserts into opposite end of switch plug Risk of electric shock Can shock burn or kill Pump should always be electrically grounded to a suitable electrical ground such as a grounded water pipe or a properly grounded...

Страница 5: ...r if plugged otherwise replace pump Check valve installed without vent hole Drill a 1 16 1 8 1 6mm 3 2mm dia hole between pump discharge check valve 1 2 above where the discharge pipe screws into the pump discharge and below the waterline Restricted intake screen Remove the pump and clean out the intake screen Check valve is installed either backward or upside down Be sure check valve is installed...

Страница 6: ...7 Ref Description Qty FPZS25T FPZS33T FPZS50T FPZS33V FPZS50V FPZS75V 1 Power Cord Assembly 1 PS117 54 TSU 2 Tethered Float Assembly 1 FP18 15BD 3 Vertical Float Switch Assembly 1 FPS17 66 4 Screw 8 32 x 7 8 4 5 Motor 1 6 Upper Volute 1 See Chart 7 Screw 8 32 x 1 2 5 8 Impeller 1 See Chart 9 Lower Volute 1 PS1 326 10 Screw 8 x 5 8 coarse thread Sheet Metal Screw 6 PLASTIC SERIES 1 2 3 4 6 8 9 10 L...

Отзывы: