background image

For parts or assistance, call Flotec Customer Service at 

1-800-365-6832

Safety / Performance / Installation

2

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol. 

When you see this

symbol on your pump or in this manual, look for

one of the following signal words and be alert to the
potential for personal injury:

warns about hazards that 

will 

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

can

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

will

or 

can

cause

minor personal injury or property damage if ignored.

The label 

NOTICE

indicates special instructions which

are important but not related to hazards.

Carefully read and follow all safety instructions in this
manual and on pump.

Keep safety labels in good condition. 
Replace missing or damaged safety labels.

1. Read this manual carefully. Failure to follow these

Instructions could cause serious bodily injury and/or
property damage.

2. Check your local codes before installing. You must

comply with their rules. 

3. Vent sewage or septic tank according to local codes.

4. Do not install pump in any location classified as 

hazardous by National Electrical Code, ANSI/NFPA
70-1990.

Hazardous voltage, Can shock, burn or

cause death. 

During operation, the pump is in water. To

avoid fatal shocks, proceed as follows if pump needs ser-
vicing:

Risk of electrical shock. Can burn or kill.

Do not lift pump by power cord. See “Cord Lift
Warning” on Page 5.

5A. Disconnect power to outlet box before unplugging

pump.

5B. Take extreme care when changing fuses. Do not

stand in water or put your finger in fuse socket.

5C. Do not modify cord and plug. When using cord and

plug, plug into a grounded outlet only. When wiring
to a system control, connect pump ground lead to
system ground.

6. Do not run pump dry. Dry running can overheat

pump, (causing burns to anyone handling it) and will
void warranty. 

7. Pump normally runs hot. To avoid burns when ser-

vicing pump, allow it to cool for 20 minutes after
shut-down before handling it.

8. In normal service, motor should not need oiling. Motor

has been filled at the factory with a special oil.

INSTALLATION

NOTICE:

Install pump on a hard, level surface (cement,

asphalt, etc.). Never place pump directly on earth, clay
or gravel surfaces.

Piping – Effluent Applications 
(3/4" or Less Solids)

Piping must be 1-1/2" minimum to carry volume of
pump discharge. Check local codes to determine if a
check valve is required in your system. In cold climates,
check valves are not used to prevent effluent from freez-
ing in piping.

If using as a sump pump, a check valve is recommended.

Piping – Sewage Applications 
(2" or Less Solids)

In any case, piping must not be smaller than pump dis-
charge.

When installed in a sewage system, pipe must be capable
of handling semi-solids of at least 2” (5.1 cm) diameter.

The rate of flow in the discharge pipe must keep any
solids present in suspension in the fluid. To meet mini-
mum flow requirements (2 feet (.6 m) per second in dis-
charge line), size pipe as follows:

A Pipe Size Of:

Will Handle a Flow Rate Of:

1-1/2" (3.8 cm)

12 GPM (45 LPM)

2" (5.1 cm)

21 GPM (79 LPM)

2-1/2" (6.3 cm)

30 GPM (113 LPM)

3" (7.6 cm)

48 GPM (181 LPM)

PERFORMANCE

GPH (LITERS) AT DISCHARGE FT. OF HEAD

Model

5 (1.5m)

10 (3m)

15 (4.6m)

20 (6.1m)

25 (7.6m)

FPSE2800A

3180 (12,038)

2700 (10,221)

2100 (7,949)

1500 (5,678)

750 (2,839)

FPSE3200A

3900 (14,763)

2550 (9,653)

960 (3,634)

0

Содержание FPSE2800A

Страница 1: ...h Pages 2 6 Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Français Pages 7 11 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 800 365 6832 Español Paginas 12 16 P O Box 342 Delavan WI 53115 Phone 1 800 365 6832 Fax 1 800 5...

Страница 2: ... fuses Do not stand in water or put your finger in fuse socket 5C Do not modify cord and plug When using cord and plug plug into a grounded outlet only When wiring to a system control connect pump ground lead to system ground 6 Do not run pump dry Dry running can overheat pump causing burns to anyone handling it and will void warranty 7 Pump normally runs hot To avoid burns when ser vicing pump al...

Страница 3: ... into an electrical outlet Connect or wire pump to an individual branch circuit with no other outlets or equipment in the circuit Size fuses or circuit breakers according to chart below Risk of electrical shock and fire Be sure that power supply information Voltage Hertz Phase on pump motor nameplate matches incoming power supply exactly Install pump according to all electrical codes that apply OP...

Страница 4: ...8 FPSE3200A 08 No Description Qty 115 Volt 115 Volt 1 Lower Volute 1 PW1 12P PW1 11P 2 Impeller 1 PW5 13P PW5 15P 3 Upper Volute 1 PW1 10P PW1 10P 4 Power Cord 1 PS117 51 TSE PS117 53 TSE 5 Automatic Float Switch 1 PS17 92 FP18 15BD 4 3 2 1 5 REPAIR PARTS LIST 2800A 3200A SERIES IF MOTOR FAILS REPLACE PUMP ...

Страница 5: ...ely disconnect from power source for 30 minutes to allow motor to cool then reconnect to power source Check for cause of overheating overloading 1 Be sure all valves in discharge valve are fully open 2 Clean out discharge pipe and check valve 3 Check for blockage in pump inlet or impeller 4 Pump not sized properly A higher capacity pump may be required 1 Check switch or controller automatic floats...

Страница 6: ...t misapplication tampering alteration nor due to improper installation operation mainte nance or storage nor to other than normal application use or service including but not limited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommended maximums Requests for service under this warranty shall be made by returning...

Страница 7: ...on du cordon et du connecteur ne les enficher que dans une prise de courant reliée à la terre Lorsque la connexion se fait vers le boîtier de commande du système relier le fil de masse de la pompe à la prise de terre du système 6 Ne pas faire fonctionner la pompe à vide Faire fonctionner la pompe sans eau risque de la faire surchauffer et de causer ainsi des brûlures et annule la garantie 7 La pom...

Страница 8: ...ant Brancher le connecteur ou directement les fils de la pompe sur circuit de dérivation individuel spécifique libre de tout autre équipement ou prise de courant Sélectionner fusibles ou dis joncteur en fonction du tableau ci dessous Risque d électrocution et d incendie S assurer que les informations relatives à l alimentation tension fréquence en Hertz phase sur la plaquette d identifica tion de ...

Страница 9: ...E2800A 08 FPSE3200A 08 No Description Qté 115 Volt 115 Volt 1 Volute inférieure 1 PW1 12P PW1 11P 2 Rotor 1 PW5 13P PW5 15P 3 Volute supérieure 1 PW1 10P PW1 10P 4 Cordon d alimentation 1 PS117 51 TSE PS117 53 TSE 5 Contact flotteur autom 1 PS17 92 FP18 15BD 4 3 2 1 5 LISTE DES PIÈCES DE RECHANGE 2800 3200A Série SI LE MOTEUR TOMBE EN PANNE REMPLACER LA POMPE ...

Страница 10: ... minutes pour permettre au moteur de refroidir puis rebrancher l alimentation Rechercher la cause de la surchauffe de la surcharge 1 Vérifier si toutes les valves de la valve de refoulement sont complètement ouvertes 2 Nettoyer le tuyau d évacuation et vérifier la valve 3 Vérifier si la crépine d entrée ou le rotor ne sont pas bloqués 4 La capacité de la pompe ne convient pas Il est peut être néce...

Страница 11: ...ui n ont pas été installés utilisés entreposés ou entretenus correctement ni à ceux qui n ont pas été utilisés ou entretenus normalement y compris mais sans s y limiter aux produits ayant des pan nes de fonctionnement causées par la corrosion la rouille ou autre corps étranger dans le système ou à des produits ayant fonctionné à des pressions dépassant la limite maximale recommandée Les demandes d...

Страница 12: ...biar los fusibles No trabaje con los pies en el agua ni introduzca sus dedos en el zócalo del fusible 5C No modifique el cable y el enchufe Si usa cable con enchufe utilice sólo una toma con conexión a masa Si conecta a un sistema de control ponga a tierra el cable conector de tierra de la bomba 6 No haga funcionar la bomba en seco El funcionamiento en seco sobrecalienta la bomba puede causar quem...

Страница 13: ...a debe conectarse a su propio un ramal individual y no deben colocarse otras tomas o equipo en ese circuito Los fusibles o disyuntores de circuito deben tener la capacidad que se indica en el cuadro que figura más abajo Peligro de descarga eléctrica e incendio Asegúrese de que la información sobre la corriente eléctrica voltaje frecuencia y número de fases inscrita en la chapa del motor de la bomb...

Страница 14: ...00A 08 Réf de piezas Cantidad 115 Volt 115 Volt 1 Voluta inferior 1 PW1 12P PW1 11P 2 Rodete 1 PW5 13P PW5 15P 3 Voluta superior 1 PW1 10P PW1 10P 4 Cable de alimentación 1 PS117 51 TSE PS117 53 TSE 5 Interruptor automático de flotador 1 PS17 92 FP18 15BD 4 3 2 1 5 LISTA DE PIEZAS DE REPUESTO 2800A 3200A SERIE SI EL MOTOR FALLA REEMPLACE LA BOMBA ...

Страница 15: ... motor se enfríe luego vuelva a conectarla a la corriente eléctrica Investigue la causa del sobrecalentamiento o sobrecarga 1 Asegúrese de que todas las válvulas en la tubería de descarga estén totalmente abiertas 2 Limpie el caño de descarga y verifique la válvula 3 Verifique que la entrada de la bomba o el rodete no estén bloqueados 4 Quizás la bomba no tenga el tamaño correcto y es posible que ...

Страница 16: ...ciones contraindicadas mane jo indebido alteraciones ni debido a instalación funcionamiento mantenimiento o almacenaje incorrectos ni a ningu na otra cosa que no sea su aplicación uso o servicio normales incluyendo pero no limitado a fallas operacionales causadas por corrosión oxidación u otros elementos extraños en el sistema o funcionamiento a presión por encima del máximo recomendado Los pedido...

Отзывы: