Specifications and Safety

2

DESCRIPTION

This Submersible Sump Pump is designed for home
sumps. Unit is equipped with a 3-prong grounding-
type power cord. Shaded-pole motor is oil filled and
sealed for cooler running. Sleeve bearings on motor
shaft never need lubrication. Automatic reset thermal
protection.

SPECIFICATIONS

Power supply required ...........................115V, 60 HZ.
Liquid Temp. Range ................32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.) ....15 Amps
Discharge:................................................1-1/2" FNPT

NOTICE:

This unit is not designed for applications

involving salt water or brine! Use with salt water or
brine will void warranty.

Pump water only with this pump.

Do not use where water recirculates.

Not designed as a swimming pool drainer.

PERFORMANCE

ELECTRICAL & SWITCH SPECIFICATIONS

GENERAL SAFETY INFORMATION

Electrically powered sump pumps normally give
many years of trouble-free service when correctly
installed, maintained, and used. However, unusual
circumstances (interruption of power to the pump,
dirt/debris in the sump, flooding that exceeds the
pump’s capacity, electrical or mechanical failure in
the pump, etc.) may prevent your pump from
functioning normally. To prevent possible water
damage due to flooding, consult your retailer about a
secondary AC sump pump, a DC backup sump
pump, and/or a high water alarm. See the
“Troubleshooting Chart” in this manual for
information about common sump pump problems
and remedies. For more information, see your
retailer, call Flotec customer service at 
1-800-365-6832 or visit our website at
www.flotecwater.com.

1. Know the pump application, limitations, and

potential hazards.

2.

Do not use in water with fish present. If any oil
leaks out of the motor it can kill fish.

3. Disconnect power before servicing.
4. Release all pressure within system before

servicing any component.

5. Drain all water from system before servicing.
6. Secure discharge line before starting pump. An

unsecured discharge line will whip, possibly
causing personal injury and/or property damage.

7. Check hoses for weak or worn condition before

each use, making certain that all connections are
secure.

8. Periodically inspect sump, pump and system

components. Keep free of debris and foreign
objects. Perform routine maintenance as
required. 

9. Provide means of pressure relief for pumps whose

discharge line can be shut-off or obstructed.

10. Personal Safety:

a. Wear safety glasses at all times when working

with pumps.

b. Keep work area clean, uncluttered and

properly lighted – replace all unused tools
and equipment.

c. Keep visitors at a safe distance from work area.
d. Make workshop child-proof – with padlocks,

master switches, and by removing starter keys.

11. When wiring an electrically driven pump, follow

all electrical and safety codes that apply.

12.

This equipment is only for use on 115 volt
(single phase) and is equipped with an
approved 3-conductor cord and 3-prong,
grounding-type plug.

To reduce risk of electric shock,

pull plug before servicing. This pump has not
been investigated for use in swimming pool
areas. Pump is supplied with a grounding
conductor and grounding-type attachment plug.
Be sure it is connected only to a properly
grounded grounding-type receptacle.
Where a 2-prong wall receptacle is encountered,
it must be replaced with properly grounded 
3-prong receptacle installed in accordance with
codes and ordinances that apply.

13. All wiring should be performed by a qualified

electrician.

14. Make certain power source conforms to

requirements of your equipment.

15. Protect electrical cord from sharp objects, hot

surfaces, oil, and chemicals. Avoid kinking cord.
Replace or repair damaged or worn cords 
immediately.

16. Do not touch an operating motor. Modern motors

can operate at high temperatures.

TOTAL FEET (M)

Motor

5

10

15

Series

HP

(1.5m)

(3m)

(4.6m)

CAPACITY GALLONS(L)/HOUR

FPSC2150A

1/3

2760

2160

1410

20 Ft.

(10 448)

(8176)

(5337)

(6.1M)

FPSC3150A

1/2

3200

2700

2000

24 Ft.

(12 113) (10 220)

(7 570)

(7.3M)

No flow 

at height

shown

below

Individual

Branch

*Switch Setting

Motor

Circuit

in inches (cm)

Series

HP

Req.(Amps)

On

Off

FPSC2150A

1/3

15

7-1/2"(19)

3"(7.6)

FPSC3150A

1/2

15

7-1/2"(19)

3"(7.6)

Содержание FPSC2150A

Страница 1: ...ages 2 6 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 7 11 Instalaci n Operaci n Piez...

Страница 2: ...rge line will whip possibly causing personal injury and or property damage 7 Check hoses for weak or worn condition before each use making certain that all connections are secure 8 Periodically inspec...

Страница 3: ...5 V 60 Hz operation and requires a minimum 15 amp individual branch circuit Both pump and switch are supplied with 3 wire cord sets with grounding type plugs Switch plug is inserted directly into outl...

Страница 4: ...and locate source of binding Float obstructed Remove obstruction Pump starts and stops Backflow of water from piping Install or replace check valve too often Faulty float switch Replace float switch...

Страница 5: ...PSC3150A 1 Power Cord Assembly 1 PS117 54 TSU PS117 53 TSU 2 Screw 1 U30 955PS U30 955PS 3 Vertical Float Switch Assembly 1 FPS17 66 FPS17 66 4 Screw 8 32x7 8 Hex Head 4 U30 951PS U30 951PS 5 Motor 1...

Страница 6: ...0AC FP0FDC 1 3 HP Submersible Sump Pumps Pool Cover Pump Model FP0S1790PCA Utility Pump Model FP0S4100X 2 Years Condensate Pump Model FPCP 20ULST INTELLIPUMP Model FP0S1775A Back up Sump Pump System M...

Страница 7: ...ctionner la pompe Une canalisation de refoulement non immobilis e risque de se d placer comme un fouet et de causer des blessures corporelles et ou des dommages mat riels 7 Avant chaque utilisation s...

Страница 8: ...surer de percer le trou sous le niveau de l eau et sous le clapet de non retour pour emp cher la formation de bouchons d air 7 Courant lectrique La pompe est con ue pour fonctionner sur le courant lec...

Страница 9: ...se du blocage Obstruction du flotteur D gager le mouvement du flotteur La pompe d marre et Reflux du liquide dans Installer un clapet de retenue s arr te trop souvent la pompe Interrupteur du flotteur...

Страница 10: ...cord n lectrique 1 PS117 54 TSU PS117 53 TSU 2 Vis 1 U30 955PS U30 955PS 3 Interrupteur flotteur vertical 1 FPS17 66 FPS17 66 4 Vis t te hexagonale n 8 32 x 7 8 de pouce 4 U30 951PS U30 951PS 5 Moteur...

Страница 11: ...pe usage g n ral mod le FP0S4100X INTELLIPUMP mod le FP0S1775A 2 ans Pompe de r cup ration des eaux condens es mod le FPCP 20ULST Syst me de pompage de secours de puisard de soutien mod le FP2800DCC P...

Страница 12: ...n marcha la bomba Una tuber a de descarga que no est bien segura puede moverse y causar lesiones personales y o da os materiales 7 Antes de cada uso verifique si las mangueras est n d biles o gastadas...

Страница 13: ...omba est dise ada para funcionar con corriente de 115 V 60 Hz y requiere un ramal individual m nimo de 15 amps Tanto la bomba como el interruptor vienen con juegos de cordones de 3 conductores con enc...

Страница 14: ...onde el rodete se traba El movimiento del flotante Retire las obstrucciones est obstruido La bomba se pone en Hay retroceso de agua de Instale una v lvula de retenci n marcha y se detiene con la tuber...

Страница 15: ...de corriente 1 PS117 54 TSU PS117 53 TSU 2 Tornillo 1 U30 955PS U30 955PS 3 Unidad del interruptor de flotador vertical 1 FPS17 66 FPS17 66 4 Tornillo cabeza hexagonal 8 32x7 8 4 U30 951PS U30 951PS 5...

Страница 16: ...e agua en l nea 90 d as Bomba para todo uso modelos FP0F360AC FP0FDC Bombas de sumidero sumergibles de 1 3 HP INTELLIPUMP modelo FP0S1775A Bomba para cubiertas de piscina modelo F0S1790PCA 2 a os Bomb...

Отзывы: