background image

INSTALLATION

Connect system pipe to port on tank cover flange. Use plastic or
steel pipe as required. To prevent leaks, use Teflon tape or Plasto-
Joint St k

1

on male threads of all threaded connections to tank.

Flush all air out of piping system and water reservoir portion of pre-
charged tank. Required on: new installations, pumps requiring
repriming and pumps disassembled for service. Do as follows:

1. Open faucets furthest from tank and run pump.

2. Allow pump to run until sputtering stops and steady stream of

water runs.

3. Open and close faucets repeatedly until sure all air has been

removed.

4. If stream does not become steady, air may be leaking into sys-

tem; check for leaks in piping on suction side of pump.

NOTICE: To prevent waterlogging, check tank air charge annually.

STANDARD TANK REPLACEMENT

When replacing standard tank in water system with pre-charged
tank, no bleeder orifices or Air Volume Control (AVC) are required.

Hazardous voltage and hazardous pressure.

Disconnect all power to pump and bleed all pressure from sys-
tem before working on pump, tank, or piping.

For jet pump installation, remove AVC tube from port in pump body
or jet body and plug port (see Fig. 3).

MAINTENANCE

In areas where temperature is high for long periods of time, tank
pre-charge pressure may increase. This may reduce tank drawdown
(amount of water available per cycle). If this occurs, reduce pre-
charge pressure to 2 PSI (14kPa) below pump ON pressure setting.

TO CHECK TANK AIR CHARGE

If drawdown decreases significantly, check as follows:

1. To check air charge in tank, shut off electric power to pump, open

faucet near tank, and drain completely.

2. At air valve, check air pressure with tire gauge. Pressure should

be 2 PSI (14kPa) below pump ON pressure setting.

3. If air pressure is more than 2 PSI (14kPa) below the ON setting,

add air to tank. Use air compressor or portable air storage tank.

4. Use soap or liquid detergent to check for air leaks around air

valve. Continuous bubbling indicates leak. If necessary, install
new core in air valve, (same as used for automobile tubeless
tires.)

TESTING FOR BLADDER LEAKAGE

1. Disconnect power to pump.

2. Drain water from tank bladder by opening faucet closest to tank.

3. Remove valve cap and release all pressure by depressing valve

core. When air stops coming from valve, remove valve core to
release remaining pressure.

4. Disconnect piping from elbow on tank cover flange.

5. Carefully turn tank upside down or lay on its side.

Retained water in tank may cause sudden

weight shift when lowering. Support tank so it cannot fall
when being lowered or inverted.

6. If bladder leaks, water will run out of valve. If so, replace bladder.

7. If replacing bladder, be sure air and water pressures are relieved

before removing cover flange. When reassembling cover flange,
do not tighten nuts or mounting studs more than 85 in- bs. (9.6
Nm).

1

Lake Chemical Co., Chicago, IL

3

English

148 0893

Figure 3 – Plug AVC Port
when installing 
pre-charged tank.

Содержание FP7300

Страница 1: ...ION PRÉCHARGÉ EN ACIER INOXYDABLE Installation Fonctionnement Pour plus de renseignements concernant l utilisation l installation ou l entretien téléphonez au 1 800 365 6832 Français Pages 4 5 MANUAL DEL USUARIO DEPÓSITO BAJO PRESIÓN PRECARGADO DE ACERO INOXIDABLE Instalación Operación Para mayor información sobre el funcionamiento instalación o mantenimiento del equipo Llame al 1 800 365 6832 Esp...

Страница 2: ...ow pump tank or piping system to freeze Freezing can severely damage equipment and may lead to tank explosion and serious injury Allowing tank to freeze voids tank warranty GENERAL INFORMATION Tanks are factory pre charged with air to 20 pounds per square inch PSI 138kPa When installing tank adjust pre charge to 2 PSI 14kPa below pump ON pressure setting To do this bleed or add air from valve on t...

Страница 3: ...reduce pre charge pressure to 2 PSI 14kPa below pump ON pressure setting TO CHECK TANK AIR CHARGE If drawdown decreases significantly check as follows 1 To check air charge in tank shut off electric power to pump open faucet near tank and drain completely 2 At air valve check air pressure with tire gauge Pressure should be 2 PSI 14kPa below pump ON pressure setting 3 If air pressure is more than 2...

Страница 4: ...servoir Si la pression de refoulement du système peut dépasser 689 kPa 100 PSI installer un clapet de surpression capable d assurer le plein débit de la pompe à 689 kPa 100 PSI Ne pas soumettre au gel la pompe le réser voir de la pompe ou la canalisation Le gel peut endommager gravement l équipement et risque d entraîn er l explosion du réservoir et de provoquer des blessures graves L exposition d...

Страница 5: ...vée pendant de longues périodes la pression préchargée du réservoir risque d aug menter et de réduire ainsi l effort de tirage du réservoir quantité d eau disponible par cycle Dans ce cas réduire la pression accumulée en la réglant à 14 kPa 2 PSI au dessous du niveau de pression MARCHE ON de la pompe POUR VÉRIFIER L ACCUMULATION D AIR DANS LE RÉSERVOIR Si l effort de tirage diminue sensiblement ef...

Страница 6: ... producir el reventón del tanque Si la presión de des carga del sistema puede superar las 100 lib pulg 2 689 kPa instale una válvula capaz de admitir el caudal pleno de la bom ba a 100 lib pulg 2 689 kPa No permita que la bomba el tanque o el sistema de tuberías se congelen El congelamiento puede pro ducir graves daños al equipo provocar la explosión del tanque y causar lesiones graves La garantía...

Страница 7: ...emperaturas permanecen a un valor elevado durante períodos prolongados la presión de precarga del tanque puede aumentar Esto podrá tener el efecto de reducir el volumen de extracción o sea la cantidad de agua que puede extraerse por ciclo Si tal ocurriera reduzca la presión de precarga hasta 2 lib pulg 2 14 kPa por debajo de la presión de ajuste de conexión ON del interruptor manométrico VERIFICAC...

Страница 8: ...s pressions dépas sant la limite maximale recommandée Les demandes de service en vertu de la présente garantie seront faites en retournant le produit défectueux au détaillant ou à FLOTEC Wicor dès la découverte de tout défaut allégué FLOTEC Wi cor prendra alors les mesures correctives aussi rapidement qu il est raisonnablement possible Aucune demande de service en vertu de la présente garantie ne ...

Страница 9: ......

Отзывы: