For parts or assistance, call Flotec Customer Service at 

800-365-6832

Operation 3

Operation

 Risk of electric shock. Can shock, burn or kill. 

Do not handle pump or pump motor with wet hands or when 

standing on wet or damp surface, or in water. Disconnect 

power from pump before handling, servicing, or attempting to 

repair pump.
NOTICE The power cord for this pump is equipped with a 

Ground Fault Circuit Interrupter (GFCI). The GFCI will shut 

down the pump in the event of leakage of electrical current 

from the pump motor or cord to ground. If the pump does not 

respond when plugged in, unplug it, reset the GFCI (push the 

RESET button on the plug) and plug it in again. If it still doesn’t 

respond, make sure that the circuit breaker for the branch 

circuit is in the ‘on’ position (closed). if the circuit breaker 

is closed and the pump doesn’t respond, consult a licensed 

electrician. DO NOT TRY TO MODIFY the cord or plug, and 

do not remove the GFCI.
The Electronic Pool Cover Pump is fully automatic in operation. 

The “smart” controller starts the pump every 2-1/2 minutes 

and causes it to run for 5 seconds. If it senses that there is no 

water to the pump, it stops. If it senses water, it continues to 

run until the water is pumped down to 1/4” deep, and then 

it stops. It then goes into a 7-minute quick-detection cycle, 

starting 4 times the first minute, twice the second minute, and 

once a minute for the next 5 minutes. If by the last check it 

has not detected water, it resumes its cycle (running 5 seconds 

every 2-1/2 minutes) until it senses water again.
NOTICE When you plug the pump into the outlet, it will start 

and run for 5 seconds. It will then cycle as described above.
If the unit is put in the water and started, interrupting the water 

flow into the pump during the 5-second water-sensing run will 

cause it to wait 2-1/2 minutes before restarting.
1.  The motor is equipped with an automatically resetting 

thermal overload protector. If the motor gets too hot, 

the overload protector will stop the motor before it is 

damaged. When the motor has cooled sufficiently, the 

overload protector will reset itself and the motor will 

restart.

 

NOTICE If the overload protector stops the pump 

repeatedly, disconnect the power from the pump and check 

it to find the problem. Low voltage, clogged impeller, 

too much back pressure in the discharge hose (as when 

pumping through 50’ (15 M) of coiled hose), or extended 

running of pump with no load, can all cause overheating.

2.  The water being pumped cools the motor, allowing the 

pump to run continuously at any depth of water above 1/4”. 

However, if the motor overload stops the pump, allow it to 

cool for one hour before restarting. The motor will not restart 

before the overload has cooled. 

Locked Rotor

1.  If the pump tries to start and senses that the rotor is locked, 

it will shut off, wait 2-1/2 minutes, and try to restart.

2.  If the rotor has unlocked, the pump will resume normal 

operation. If the rotor is still locked, the pump will shut off 

again and wait through another 2-1/2 minute cycle.

3.  After 2-1/2 minutes, the pump will again try to start. If 

the rotor has unlocked, the pump will resume normal 

operation. If the rotor is still locked, the pump will shut off 

and will not restart automatically.

4.  To restart the pump manually, unplug it and plug it in again. 

5.  If the rotor is still locked, UNPLUG THE PUMP, remove 

the base, shield, and screen, and clean out the rotor. 

 Risk of electric shock. Can shock, burn or 

kill. Disconnect the pump from the power source before 

disassembling the pump or cleaning out the rotor.
6.  See Page 4 for important information about the alignment 

of the screen and shield when you reassemble them. Note 

that the pump will not operate correctly if these parts are 

not correctly installed.

7.  Once you have reassembled the pump, reset it on the pool 

cover and plug it in again to resume normal operation.

Airlocks

When a pump airlocks, it runs but does not move any water. 

An airlock will cause the pump to overheat and fail. This 

pump has an anti-airlock hole in the bottom of the pump 

body. If you suspect an airlock, unplug the pump, clean out 

the anti-airlock hole with a paper clip or piece of wire, and 

restart the pump.
NOTICE If the outlet of the discharge hose is submerged you 

must have a 1/8” hole in the discharge hose to prevent airlock. 

This hole must be open to air.
NOTICE If you move the pump or the pump airlocks, be sure to 

drain the hose before trying to restart the pump.

Содержание FP0S1790PCA

Страница 1: ...Call 800 365 6832 English Pages 2 5 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 800 365 6832 Fran ais Pages 6 9 I...

Страница 2: ...of debris and foreign objects Specifications Power supply required 115V 60 HZ Liquid Temp Range Max 77 F 25 C Operation Position Vertical Individual Branch Circuit Required 15 Amp Operating Depth Begi...

Страница 3: ...ll restart NOTICE If the overload protector stops the pump repeatedly disconnect the power from the pump and check it to find the problem Low voltage clogged impeller too much back pressure in the dis...

Страница 4: ...32 and order part number PW73 63 If motor fails replace entire pump Assemble Screen and Shield as shown Symptom Possible Cause s Corrective Action Pump won t start or run Blown fuse If blown replace w...

Страница 5: ...vice Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return t...

Страница 6: ...bris et de corps trangers Caract ristiques techniques Alimentation requise 115V 60HZ Temp rature du liquide gamme Max 25 C 77 F Position en marche Verticale Circuit de d rivation individuel requis 15...

Страница 7: ...de fa on r p titive d brancher la pompe et d terminer le probl me Une basse tension un impulseur bouch une contre pression trop importante dans le tuyau de refoule ment comme pomper de l eau dans un...

Страница 8: ...er 2i me 3i me Ins rer les vis travers la base La base est omise pour fins de clart Sympt mes Cause s probable s Action corrective Le pompe ne d marre pas Le fusible a saut S il a saut le remplacer av...

Страница 9: ...ntent un risque de contamination En cas de d faillance de la pompe d eaux d gout Porter des gants en caoutchouc pour manipuler la pompe des fins de garantie retourner l tiquette figurant sur le cordon...

Страница 10: ...tura del l quido M x 25 C 77 F Posici n de operaci n Vertical Requiere un ramal individual 15 A Nivel de operaci n M n inicial 19 1 mm 3 4 nivel de agua M x final 6 4 mm 1 4 Descarga 1 NPT AVISO Esta...

Страница 11: ...ma Tensiones bajas impulsores bloqueados demasiada presi n en la manguera de descarga como en los casos en que se bombea a trav s de 50 pies 15 metros de manguera enre dada o una operaci n prolongada...

Страница 12: ...anti airlock Apriete 1o 2o 3o Insertar los tornillos a trav s de la base No se muestra la base para mayor claridad S ntoma Causas probablesll Soluci n La bomba no arrancao no funciona Fusible fundido...

Страница 13: ...partamento de Atenci n al Cliente de FLOTEC Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci n Si su bomba cloacal ha fallado Use guan...

Страница 14: ...14 For parts or assistance call Flotec Customer Service at 800 365 6832...

Страница 15: ...15 For parts or assistance call Flotec Customer Service at 800 365 6832...

Страница 16: ......

Отзывы: