Flotec ergon 5000 Скачать руководство пользователя страница 3

1

Dear 

Customer, 

        

congratulations on your purchase of this product! As with all 

FLOTEC articles

, this product has been designed in accordance with the 

most advanced technical principles and has been manufactured using the most modern and reliable electrical/electronic components. 
We recommend that you dedicate a few moments to carefully reading the following use instructions prior to using the apparatus for the 
first time. 
Thank you! 
 
 

 
Index 
Chap. 1 

Safety 

regulations 

    

page 1 

Chap. 2 

Restrictions in use 

 

 

 

page 2 

Chap. 3 

Electrical connections 

 

 

 

page 2

 

Chap. 4 

Functions 

    

page 3

 

Chap. 5 

Installation 

    

page 3

 

Chap. 6 

Starting 

up 

    

page 4

 

Chap. 7 

Maintenance and troubleshooting 

 

 

page 5

 

Appendix 

Figures 

    

page 

37

 

 

Safety warnings for persons and things. 
Pay particular attention  to the wording marked with the following: 
 

    

 

DANGER 

Warns that failure to observe the prescriptions may result in 
serious risk to persons and/or things   

 

RISK 
ELECTRICAL LOADS 

Warns that failure to observe the prescriptions may result in the 
risk of an electric shock 

 
WARNINGS 

Warns that failure to observe the prescriptions may result in 
damage to the pump and/or the system 

 

 

 

Chap. 1 Safety regulations 
 

Keep technical apparatus out of the reach of children 

 

 

Avoid all contact with water when the pump is connected to the electric supply: ensure that the pump and the 
electric connections are in a position safe from flooding and do not power the pump if it is under water. 
The supply cable may only be replaced by qualified personnel 
 
 
Always remove the plug when the pump is not being used and prior to any type of intervention (priming, 
maintenance, cleaning).  
 

 

- Prior to installation ensure that this manual has been read and store carefully. Damages caused by non-observance of the 
indications contained in the manual are not covered by warranty. 
 
- Carefully store the present manual. If there are problems please contact the customer services only after having ensured that no 
error in use has occurred or that the problem has not been caused by an external factor. 
 
- At the moment of purchase check that the pump has not suffered any transport damage. Should there be damages please contact 
the reseller immediately and not beyond 8 days from the date of purchase. 
 
- Do not use the cable to transport the pump or use the cable to pull the plug out of the plug hole.  
Protect the plug and the supply cable from heat, oil and sharp edges. 
 
- Using the electro-pump with inflammable, corrosive or explosive liquids is prohibited. 
 
- Ensure that the voltage and the frequency on the i.d. plate correspond to that of the supply network available. 

 

- Avoid exposing the pump to humidity. Protect the pump from rain. Ensure that there are no connections which drip above the 
pump Do not use the pump in wet or humid areas. 
 
- Always visually check the pump before use (above all  the supply cable and the plug). The pump must not be used if it is damaged. 
If it is damaged ensure that it is checked by customer service personnel only. 
 
- In fixed installations the electric plug must be located in a visible and accessible position. 
 

       GB 

7

Содержание ergon 5000

Страница 1: ...tenzione pag 1 I Use and maintenance manual 7 GB Manuel d utilisation et d entretien 13 F Bedienungs und Wartungsanleitung 19 D Manual de uso y manutenci n 25 E Bycnherwbb gj ecnfyjdrt b aeyrwbjybhjdf...

Страница 2: ...ueaselectrobombasabaixoindicadasest oem conformidadecomosRequisitosEssenciaisdeSeguran aeTutela de Sa de contidos na Directiva 98 37 2006 95 CE 2004 108 CE e successivas modifica es CONFORMITEITSVERKL...

Страница 3: ...er The supply cable may only be replaced by qualified personnel Always remove the plug when the pump is not being used and prior to any type of intervention priming maintenance cleaning Prior to insta...

Страница 4: ...on to not exceed the maximum permitted which is equal to 6 bars Keep in mind that the start pressure to be increased and that of the pump are added together Example system pressure equal system to 1 5...

Страница 5: ...elow The pump will attempt to restart after 1 minute if a lack of water continues to be detected or electrical damage it will be stopped again A new attempt will be made after 10 minutes and then resp...

Страница 6: ...nstalling a check valve directly on the delivery Fig 1 2 ref 6 to avoid any damage to the electro pump caused by blow strokes In order to facilitate any maintenance operations we recommend the install...

Страница 7: ...UAGE parameter is displayed Once the language parameter is displayed press the SET pushbutton a number of times until the language you wish to select is displayed GB I FR D NL ES RUS Once the language...

Страница 8: ...reign bodies 4 Power supply is not according to that on the data plate 1 Extract the plug and let the pump cool down check the maximum temperature of the liquid transported 35 C Ensure that aeration i...

Отзывы: