17. Troubleshooting guide
Motor not running
Cause
Remedy
- Power supply not connected
- Impeller blocked, thermostat has swit-
ched off
- Check voltage supply
- Take pump apart and clean it
Pump not priming
Cause
Remedy
- Intake valve not in the water
- No water in the pump chamber
- Air in the intake line
- Intake valve leaking
- Intake cage (intake valve) blocked
- Max. intake height exceeded
- Place intake valve in water
- Fill pump housing with water
- Check sealing of intake line
- Clean intake valve
- Clean intake cage
- Check intake height
Insufficient pumping rate
Cause
Remedy
- Intake height too high
- Intake cage soiled
- Water level falling rapidly
- Pump performance reduced by foreign
bodies (sand, stones, etc.)
- Check intake height
- Clean intake cage
- Place intake valve lower down
- Clean pump and replace wearing parts
Thermostat switches off the pump
Cause
Remedy
- Motor overloaded, excessive friction
caused by foreign bodies
- Dismantle and clean pump, prevent in-
take of foreign bodies (filter)
Caution! The pump must not run dry.
Anleitung_LB5_4171184.indb 41
16.09.11 10:16
Содержание fgp 1000 a1
Страница 3: ... 3 1 2 4 2 1 3 9 6 8 5 7 Anleitung_LB5_4171184 indb 3 16 09 11 10 16 ...
Страница 4: ... 4 Anleitung_LB5_4171184 indb 4 16 09 11 10 16 ...
Страница 54: ... 54 Anleitung_LB5_4171184 indb 54 16 09 11 10 17 ...
Страница 55: ... 55 Anleitung_LB5_4171184 indb 55 16 09 11 10 17 ...
Страница 56: ... 56 Anleitung_LB5_4171184 indb 56 16 09 11 10 17 ...
Страница 57: ... 57 Anleitung_LB5_4171184 indb 57 16 09 11 10 17 ...