Regulations

FloPlast’s Air Admittance Valve , if installed, used and maintained in accordance with this document and supporting 

installation guides, can contribute to satisfying the relevant requirements of the following Building Regulations (the 

presence of a UK map indicates that the subject is related to the Building Regulations in the region or regions of the UK 

depicted):

The Building Regulations 2010 (England and Wales) (as amended)

Requirement:

 

H1 

Comment:

Regulation:

 

Comment:

Foul Water Drainage

The valves will:

1.  Provide adequate ventilation to prevent the loss of water seals in trapped appliances. 

See section 4, 6 and 7 of this document.

2.  Prevent foul air from entering the building. See section 7 of this document.

3.  Enable access to sanitary pipework for clearing blockages. See section 6.1 of this 

document.

4.  Contribute to the ventilation of underground drains. See section 6.2 and 6.3 of this 

document.

Material and workmanship

The products are acceptable. See section 9 amd the installation part of this document.

The Building (Scotland) Regulations 2004 (as amended)

Regulation:

 

8(1) 

Comment:

Regulation:

 

Standard:

 

3.7

Comment:

Standard:

 

7.1[a](b) 

Comment: 

Regulation:

  1

Comment:

Durability, workmanship and fitness of materials

The use of this product satisfies the requirements of this Regulation. See section and the 

installation part of this document.

Building standards applicable to construction

Wastewater drainage

The valves can meet the relevent requirements of this Standard, with reference to 

clauses 3.7.7

(2)

 and 3.7.1

(1)

. See sections 4, 6.1 to 6.4, 6.6 to 6.9 and 7 of this document.

Statement of durability

This product can contribute to meeting the relevant Requirements of Regulation 9,  

standards 1 to 6 and therefore will contribute to a construction meeting a bronze level of 

sustainability as defined in this standard.

Building Standards applicable to conversions

All comments given for product Regulation 9, Standards 1 to 6 also apply to this 

Regulation with reference to 0.12.1

(1)(2)

 and schedule 6

(1)(2)

.

The Building Regulations (Northen Ireland) 2012 (as amended)

Regulation:

 

23 (a)(i)(iii)(b)(i) 

Comment:

Regulation:

 

79 

Comment:

Fitness of materials and workmanship

The products are acceptable. See section 9 and the installation part of this document.

Material and workmanship

The products are acceptable. See section 9 amd the installation part of this document.

Drainage Systems

The products provide adequate ventialtion to maintain water seals in traps. See sections 

4, 6.1 to 6.4, 6.6 to 6.9 and 7 of this document.

Construction (Design and Management) Regulations 2015

Construction (Design and Management) Regulations (Northern Ireland) 2016

Information in this document may assist the client, designer (including Principle Designers) and contractors (including 

Principle Contractor) to address their obligations under the regulations.

Содержание AF110

Страница 1: ...itish Standards Kitemark KM512474 and CE mark as having met the performance requirements of BS EN 12380 2002 and have been designated with an A1 rating FloPlast s Air Admittance Valves provide a means...

Страница 2: ...the installation part of this document Building standards applicable to construction Wastewater drainage The valves can meet the relevent requirements of this Standard with reference to clauses 3 7 7...

Страница 3: ...also be installed directly into 100mm or 110mm European designated pipe with the use of an EPDM finned seal this product is designated AFE110 FloPlast s AF110 Air Admittance Valve as seen on the fron...

Страница 4: ...socket 82 82 0 82 3 BS EN1329 1 BS 4514 PVC AF110 AX110 Push Fit 110 110 0 110 3 BS EN 1329 1 BS EN 1455 1 BS EN 1565 1 BS EN 1566 1 BS 4514 BS5255 Multi AV110 Solvent Weld 110 110 0 110 3 BS EN1329 1...

Страница 5: ...on instructions are supplied in cardboard boxes and polyethylene bags to limit the risk of contamination or damage All valves must be stored upright in their boxes until required for use 3 2 The legen...

Страница 6: ...wellings a ventilated by FloPlast AVE100 AV110 AF110 or AX110 FloPlast AVE100 AV110 AF110 or AX110 FloPlast AF32 or AFE32 Minimum 200mm Greater than 4 metres b unventilated Up to 4 metres NOTES The ma...

Страница 7: ...le 3 and Figure 5 Table 3 Air admittance valve disposition Number of Dwellings Up to three stories in height Multi storey domestic dwelling and non domestic buildings 1 4 Additional drain and venting...

Страница 8: ...suitable form of sound insulation 6 8 In addition other than those shown in Figure 5 stacks should not be fitted with the valves when the connecting drain s are subject to periodic surcharging or are...

Страница 9: ...ied out in accordance with these instructions 11 2 FloPlast AF110 AX110 valves are supplied with a synthetic rubber connector enabling a push fit into 100mm and 110mm as indicated in Table 1 Additiona...

Страница 10: ...ecification BS 5255 1989 Specification for thermoplastics waste pipe and fittings BS EN 1329 1 2014 Plastics piping systems for soil and waste discharge low and high temperature within the building st...

Страница 11: ...c Are reviewed by the BSI as and when it considers appropriate 15 4 In issuing this document FloPlast is not responsible for a the right of the document holder to market supply install or maintain th...

Отзывы: