6
ASSEMBLY INSTRUCTIONS
NOTE:
For
DISPLAY READY
QSI
electronic modules only.
For the “Display Ready” QSI module, follow these initial instructions first to install
your customer provided display to the cover plate in the kit. Then follow the
Installation Instructions to install this customer-assembled unit to the meter
1. Make sure the QSI module and meter are disconnected from power source.
2.
Remove batteries
from your display, they will no longer be needed.
3. Remove the pickup coil from the back center of your display by cutting the two
wires that attach it to the display. Cut the wires as close to the display as
possible to ensure the cut ends do not touch the PC board inside the QSI
module. Discard the removed coil.
4. Using a small regular screwdriver, remove the clear sealant from the 10 pin
female connector holes on the backside of your display.
5. Insert the “long legs” of the 10-pin male connector that came with the kit into
the 10 pin female connector on the QSI circuit board (see Figure A).
6. Install the formed display seal into the seal gland on the backside of the display.
7.
CAREFULLY
mount the display onto the cover plate ensuring the legs of the
male 10-pin connector are inserted into
ALL
10 pin female connector holes of
the display (see Figure B).
8. Secure the display to the cover plate using the four #4-20 x 7/8 in. tapping
screws. Torque to 80-96 oz-in (0.56-0.67 Nm).
Figure A
Figure B