1.4.3
Sunshield
The camera includes a sunshield which should be used for any installation where the camera is
exposed to direct sunlight or precipitation, If the camera is mounted with the top mounting holes, the
sunshield is not used. Depending on the needs of the installation, the sunshield can be positioned in
the neutral (middle) position, or slightly forward or rearward.To change the position of the sunshield,
temporarily loosen the three 3 mm hex screws on top, slide the sunshield forward or backward, and
re-tighten the screws.
1.5
Removing the Cover
In order to access the electrical connections
and install the cables, it is necessary to
temporarily remove the top cover of the
camera housing. The top cover of the
camera is held in place with four 3 mm hex
screws. The screws are accessible through
slots in the sunshield, so the sunshield does
not need to be removed from the top cover.
Use a 3 mm hex key to loosen the four
captive screws, exposing the connections
inside the camera enclosure. There is a
grounding wire connected inside the case to
the top cover, as shown. If it (or any of the
grounding wires) is temporarily
disconnected during the installation, it must
be reconnected to ensure proper grounding
of the camera.
Caution!
Replace the cover and tighten the four 3 mm hex screws to 1.8 n-m (16.0 in-lbs).
When replacing the cover, ensure that the ground wire between the cover and the camera body is