![FLIR Exx series Скачать руководство пользователя страница 87](http://html.mh-extra.com/html/flir/exx-series/exx-series_user-manual_2305764087.webp)
Working with measurement tools
5. Use the navigation pad to select one or more of the following:
• Select
(
Max
) to display the maximum value.
• Select
(
Min
) to display the minimum value.
• Select
(
Avg
) to display the average value.
• Select (depending on the tool)
or
(
Area
) to display the area of an object
within the measurement tool. For more information, see section 10.9
• Select
(
Max & min markers
) to display the maximum and minimum markers
(the hot/cold spots).
6. Push the navigation pad to toggle the function between inactive and active:
• When the icon with the unfilled indicator
is displayed, the function is inactive.
• When the icon with the filled indicator
is displayed, the function is active.
7. When completed, push the navigation pad down to close the submenu.
8. Select
(
Done
) and push the navigation pad.
15.7
Creating and setting up a difference
calculation
15.7.1
General
A difference calculation gives the difference between the values of two known measure-
ment results.
15.7.2
Procedure
Note
• You can set up a difference calculation when defining user presets, or when editing an
image in the archive.
• This procedure assumes that you have previously laid out at least one measurement
tool on the screen.
15.7.2.1
Procedure
Follow this procedure:
1. To set up a difference calculation, do the following:
• If you are defining user presets, select
(
Add measurement
) and then select
(
Add delta
).
• If you are editing an image in the archive, select
(
Measurement
) and then select
(
Add delta
).
2. Push the navigation pad. This displays a dialog box where you can select the measure-
ment tools that you want to use in the difference calculation. You can also select a
fixed-temperature reference.
#T810190; r. AI/41890/41890; en-US
75
Содержание Exx series
Страница 1: ...User s manual FLIR Exx series ...
Страница 2: ......
Страница 3: ...User s manual FLIR Exx series T810190 r AI 41890 41890 en US iii ...
Страница 4: ......
Страница 12: ......
Страница 51: ...Handling the camera 10 T810190 r AI 41890 41890 en US 39 ...
Страница 54: ...Handling the camera 10 10 15 Lanyard strap 10 15 1 General T810190 r AI 41890 41890 en US 42 ...
Страница 226: ...Mechanical drawings 27 See next page T810190 r AI 41890 41890 en US 214 ...
Страница 228: ...CE Declaration of conformity 28 See next page T810190 r AI 41890 41890 en US 216 ...
Страница 229: ......
Страница 234: ...Application examples 29 T810190 r AI 41890 41890 en US 222 ...
Страница 275: ......
Страница 277: ......