![FLIR Elara 427-0108-00-00 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/flir/elara-427-0108-00-00/elara-427-0108-00-00_installation-and-user-manual_2305758012.webp)
This document does not contain any export-controlled information.
Installation
8
427-0108-00-10 - Revision 100 - December 2020
Interface
Description
1 Micro SD card slot To be supported in a future release.
2 USB
To be supported in a future release.
3 RESET (R)
To reboot the camera, press the button for at least one second.
4 DEFAULT (D)
To reset the camera to its factory defaults, press the button for at least six
seconds.
5 STATUS
LED (green / red / amber) that indicates camera is booting up or firmware
being upgraded.
Camera state
LED state
Description
Booting up
Solid red
for 2-3
seconds,
then:
Green
Normal
After a successful boot,
the LED turns off after
three minutes.
Red
An error has occurred.
Firmware
upgrade
Flashing amber
During upgrade
6 Anti-drop rubber
band
Makes sure the access cover does not drop. To ensure that the camera
remains waterproof, store the anti-drop rubber band inside the camera
before locking the access cover.
System cable
Connector
1 Black
RJ-45
2
Black
12-30 VDC (±10%) /
24 VAC (21-28 VAC) -
Red
12-30 VDC (±10%) /
24 VAC (21-28 VAC) +
3
Red
ALARM IN signal
Yellow
NOT USED
Black
ALARM IN GND
Orange
NOT USED
Brown
ALARM OUT signal
Purple
NOT USED
Blue
ALARM OUT COM
Green
NOT USED
2.4
Supplying Power to the Camera
The camera can be powered by PoE or by an external DC or AC power supply (not included in the
camera kit).
www.
.com
1.800.561.8187