FLIR CM83 Скачать руководство пользователя страница 46

9

Warranties

9.1

FLIR Global Limited Lifetime

Warranty

A qualifying FLIR Test and Measurement product (the
“Product”) purchased either directly from FLIR Commer-
cial Systems Inc and affiliates (FLIR) or from an author-
ized FLIR distributor or reseller that Purchaser registers
on-line with FLIR is eligible for coverage under FLIR’s Lim-
ited Lifetime Warranty, subject to the terms and conditions
in this document. This warranty only applies to purchases
of Qualifying Products (see below) purchased and manu-
factured after April 1, 2013.

PLEASE READ THIS DOCUMENT CAREFULLY; IT CON-
TAINS IMPORTANT INFORMATION ABOUT THE PROD-
UCTS THAT QUALIFY FOR COVERAGE UNDER THE
LIMITED LIFETIME WARRANTY, PURCHASER’S OBLI-
GATIONS, HOW TO ACTIVATE THE WARRANTY, WAR-
RANTY COVERAGE, AND OTHER IMPORTANT TERMS,
CONDITIONS, EXCLUSIONS AND DISCLAIMERS.

1. PRODUCT REGISTRATION

. To qualify for FLIR’s Lim-

ited Lifetime Warranty, Purchaser must fully register the
Product directly with FLIR on-line at http://www.flir.com
within Sixty (60) DAYS of the date the Product was pur-
chased by the first retail customer (the “Purchase Date”).
Qualifying PRODUCTS THAT ARE NOT REGISTERED
ON-LINE WITHIN SIXTY (60) DAYS OF THE PURCHASE
DATE WILL HAVE A LIMITED ONE YEAR WARRANTY
FROM DATE OF PURCHASE.

2. QUALIFYING PRODUCTS

. Upon registration, Test and

Measurement products that qualify for coverage under
FLIR’s Limited Lifetime Warranty are: MR7x, CM7x,
CM8x, DMxx, VP5x not including accessories which may
have their own warranty.

3. WARRANTY PERIODS

. For purposes of the The Lim-

ited Lifetime Warranty, Lifetime is defined as seven years
(7) after the product is no longer manufactured, or ten
years (10) from date of purchase, whichever is greater.
This Warranty is only applicable to the original owner of
the Products.

Any Product that is repaired or replaced under warranty is
covered under this Limited Lifetime Warranty for one hun-
dred eighty days (180) days from the date of return ship-
ment by FLIR or for the remaining duration of the
applicable Warranty Period, whichever is longer.

4. LIMITED WARRANTY. In accordance with the terms
and conditions of this Limited Lifetime Warranty, and ex-
cept as excluded or disclaimed in this document, FLIR
warrants, from the Purchase Date, that all fully registered
Products will conform to FLIR’s published Product specifi-
cations and be free from defects in materials and work-
manship during the applicable Warranty Period.
PURCHASER’S SOLE AND EXCLUSIVE REMEDY
UNDER THIS WARRANTY, AT FLIR’S SOLE DISCRE-
TION, IS THE REPAIR OR REPLACEMENT OF

DEFECTIVE PRODUCTS IN A MANNER, AND BY A
SERVICE CENTER, AUTHORIZED BY FLIR. IF THIS
REMEDY IS ADJUDICATED TO BE INSUFFICIENT, FLIR
SHALL REFUND PURCHASER’S PAID PURCHASE
PRICE AND HAVE NO OTHER OBLIGATION OR LIABIL-
ITY TO BUYER WHATSOEVER.

5. WARRANTY EXCLUSIONS AND DISCLAIMERS

.

FLIR MAKES NO OTHER WARRANTY OF ANY KIND
WITH RESPECT TO THE PRODUCTS. ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO IMPLIED WARRANTIES OF MER-
CHANTABILITY, FITNESS FOR A PARTICULAR PUR-
POSE (EVEN IF PURCHASER HAS NOTIFIED FLIR OF
ITS INTENDED USE FOR THE PRODUCTS), AND NON-
INFRINGEMENT ARE EXPRESSLY EXCLUDED FROM
THIS AGREEMENT.

THIS WARRANTY EXPRESSLY EXCLUDES ROUTINE
PRODUCT MAINTENANCE, SOFTWARE UPDATES,
AND REPLACEMENT OF MANUALS, FUSES, OR DIS-
POSABLE BATTERIES. FLIR FURTHER EXPRESSLY
DISCLAIMS ANY WARRANTY COVERAGE WHERE
THE ALLEGED NONCONFORMITY IS DUE TO NOR-
MAL WEAR AND TEAR, OTHER ALTERATION, MODIFI-
CATION, REPAIR, ATTEMPTED REPAIR, IMPROPER
USE, IMPROPER MAINTENANCE, NEGLECT, ABUSE,
IMPROPER STORAGE, FAILURE TO FOLLOW ANY
PRODUCT INSTRUCTIONS, DAMAGE (WHETHER
CAUSED BY ACCIDENT OR OTHERWISE), OR ANY
OTHER IMPROPER CARE OR HANDING OF THE
PRODUCTS CAUSED BY ANYONE OTHER THAN FLIR
OR FLIR’S EXPRESSLY AUTHORIZED DESIGNEE.

THIS DOCUMENT CONTAINS THE ENTIRE WAR-
RANTY AGREEMENT BETWEEN PURCHASER AND
FLIR AND SUPERSEDES ALL PRIOR WARRANTY NE-
GOTIATIONS, AGREEMENTS, PROMISES AND
UNDERSTANDINGS BETWEEN PURCHASER AND
FLIR. THIS WARRANTY MAY NOT BE ALTERED WITH-
OUT THE EXPRESS WRITTEN CONSENT OF FLIR.

6. WARRANTY RETURN, REPAIR AND REPLACE-
MENT

. To be eligible for warranty repair or replacement,

Purchaser must notify FLIR within thirty (30) days of dis-
covering of any apparent defect in materials or workman-
ship. Before Purchaser may return a Product for warranty
service or repair, Purchaser must first obtain a returned
material authorization (RMA) number from FLIR. To obtain
the RMA number Owner must provide an original proof of
purchase. For additional information, to notify FLIR of an
apparent defect in materials or workmanship, or to request
an RMA number, visit http://www.flir.com. Purchaser is
solely responsible for complying with all RMA instructions
provided by FLIR including but not limited to adequately
packaging the Product for shipment to FLIR and for all
packaging and shipping costs. FLIR will pay for returning
to Purchaser any Product that FLIR repairs or replaces
under warranty.

#T559825; r. AI/33557/33557; en-US

40

Содержание CM83

Страница 1: ...User s manual FLIR CM83 600 A True RMS Power Clamp Meter...

Страница 2: ......

Страница 3: ...User s manual FLIR CM83 T559825 r AI 33557 33557 en US...

Страница 4: ......

Страница 5: ...of range warning 13 5 Operation 14 5 1 Powering the meter 14 5 1 1 Auto power off 14 5 2 Auto Manual select mode 14 5 3 Auto Manual range mode 15 5 4 Hold mode 15 5 4 1 Smart hold 15 5 5 Silent mode 1...

Страница 6: ...enance 31 6 1 Cleaning and storage 31 6 2 Battery replacement 31 6 2 1 Disposal of electronic waste 31 7 Technical specifications 32 7 1 General specifications 32 7 2 Electrical specifications 33 8 Te...

Страница 7: ...Quality Management System under which these products are developed and manufactured has been certi fied in accordance with the ISO 9001 standard FLIR Systems is committed to a policy of continuous de...

Страница 8: ...and or national legislation for the electrical inspections can ap ply Incorrect operation of the device can cause damage shock injury or death to persons WARNING Do not start the measuring procedure b...

Страница 9: ...ice show signs of dam age Injury to persons can occur WARNING Be careful when you do the measurements if the voltages are more than 25 VAC rms or 35 VDC There is a risk of shock from these voltages In...

Страница 10: ...made for This can cause damage to the protection This symbol adjacent to another symbol or terminal indicates that the user must refer to the manual for further information This symbol adjacent to a t...

Страница 11: ...measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiv...

Страница 12: ...ure compliance requirements for mobile configurations a separation distance of at least 20 cm must be maintained be tween the antenna of this device and all persons This device must not be co located...

Страница 13: ...and selection Auto resistance continuity diode selection Power and power factor measurement Total harmonic distortion and 1 to 25 harmonics Phase rotation Indication 100 k resistance capability Non c...

Страница 14: ...2 Jaw opening trigger 3 Function buttons see section 4 3 Function buttons page 10 4 Navigation buttons 5 Non contact voltage detector light 6 Function switch see section 4 2 Function switch page 9 7...

Страница 15: ...e through the probe inputs The meter can measure resistance continuity or diode polarity through the probe inputs The type of measurement is selected by the button The meter can measure power through...

Страница 16: ...to change the range scale Press the button to toggle between Normal and Hold modes see section 5 4 Hold mode page 15 Holding the button down for 2 secconds enables disables the key lock mode In Hold...

Страница 17: ...ng maximum reading values Indicates that the meter is displaying minimum reading values Indicates that the meter is displaying the average reading Indicates that the meter is displaying peak maximum v...

Страница 18: ...that the meter is measuring AC current or voltage Indicates that the meter is measuring DC current or voltage Indicates that the meter is measuring AC DC current or voltage Indicates that the continui...

Страница 19: ...4 Description 4 4 1 Out of range warning If the input is out of range OL is displayed T559825 r AI 33557 33557 en US 13...

Страница 20: ...that the battery voltage is low or if the me ter does not power on replace the battery See section 6 2 Battery replace ment page 31 5 1 1 Auto power off The meter enters sleep mode after 30 minutes of...

Страница 21: ...nction is se lected with the function switch the starting mode is Auto range and the indi cator is displayed To enter Manual range mode press the button To change the range press the button repeatedly...

Страница 22: ...the measurement range scale press the button repeatedly Refer to section 5 3 Auto Manual range mode page 15 4 Insert the black probe lead into the negative COM terminal and the red probe lead into the...

Страница 23: ...3 Auto Manual range mode page 15 5 Press the trigger to open the clamp jaws Fully enclose one conductor refer to Figure 5 1 For optimum results center the conductor in the jaws 6 Read the current valu...

Страница 24: ...Press the button to toggle between the display of Peak Max and Peak Min In Peak Max mode the indicator is displayed In Peak Min mode the indicator is displayed 3 Press and hold the button for 2 secon...

Страница 25: ...60 Hz 5 6 3 4 DC Zero mode The DC zero feature removes offset values and improves the accuracy for DC current measurements DC Zero mode is available when measuring DC or AC DC current in Manual selec...

Страница 26: ...ayed or 3 Press and hold the button for 2 seconds to disable Min Max Avg mode 5 6 3 7 Harmonic Distortion mode In Harmonic Distortion mode the meter displays the distortion percentage value for the fi...

Страница 27: ...vigation buttons to select and enable VFD mode 5 7 Non contact voltage detector NOTE Test on a known live circuit before testing on an unfamiliar circuit 1 Hold the clamp tips of the meter very close...

Страница 28: ...factor value on the display If the value is displayed without a sign the phase of the current signal is lagging behind the voltage signal inductive load If the value is displayed with a minus sign the...

Страница 29: ...ements of the active power in accordance with Figure 5 4 4 To measure and display the power factor press the button repeatedly until the indicator is displayed 5 Read the power factor value on the dis...

Страница 30: ...or is displayed 5 8 2 2 Three phase four wire balanced unbalanced The power of a three phase four wire configuration is measured in three steps accordance with Figure 5 5 The total power is the sum of...

Страница 31: ...e power factor value on the display If the value is displayed without a sign the phase of the current signal is lagging behind the voltage signal inductive load If the value is displayed with a minus...

Страница 32: ...lack test lead to the presumed phase line 3 4 One of the following results is displayed OLV flashes if the voltage is 1000 V Lo V flashes if the voltage is 30 V outF flashes if the frequency is 65 Hz...

Страница 33: ...you remove the power from the capacitors and the other devices when you do a test during a meas urement Injury to persons can occur 1 Set the function switch to the position 2 Ensure that the meter i...

Страница 34: ...lue on the display NOTE For very large capacitance values it may take several seconds for the measurement to settle and the final reading to stabilize 5 11 Continuity test WARNING Do not do diode resi...

Страница 35: ...lay will show 0 4 0 8V for a good di ode bAd for a shorted diode and O L for an opened diode See Figure 5 7 0 4V O L bAd 0 4V Figure 5 7 Diode testing 1 Set the function switch to the position 2 Inser...

Страница 36: ...ntifying an overheated cable connection you may want to know the current in that cable The Bluetooth range is 10m 32ft maximum 5 13 2 Procedure 1 Pair the IR camera with the instrument Refer to the ca...

Страница 37: ...m the terminals and set the function switch to the position before attempting to replace the batteries 2 Unscrew and remove the battery compartment cover 3 Replace the six standard AAA batteries obser...

Страница 38: ...k light and Bluetooth are off Environmental conditions Indoor use Calibration 1 year calibration cycle Operating temperatures 0 to 10 32 to 50 non condensing 10 to 30 50 to 86 80 RH 30 to 40 86 to 104...

Страница 39: ...ock vibration Random vibration per MIL PRF 28800f Class 2 5 55 Hz 3g maximum 7 2 Electrical specifications Accuracy is reading number of digits dgt at 23 5 73 4 9 80 RH Table 7 1 Voltage TRMS Function...

Страница 40: ...CF 3 460 V 280 A 2 690 V 420 A AC DC Vrms accuracy Same as ACV specification DCV specification Table 7 2 Current TRMS Function Range Accuracy DCA 99 99 A 2 0 5 A 599 9 A 2 5 dgt ACA 0 10 99 99 A 50 60...

Страница 41: ...itable for repetitive events Table 7 4 Frequency Function Range Accuracy Frequency 20 00 99 99 Hz 0 5 3 dgt 20 0 999 9 Hz 0 020 9 999 kHz Overload protection 1000 Vrms 600 Arms Sensitivity 10 100 Vrms...

Страница 42: ...Arms rdy is displayed If the fundamental frequency is outside the range 45 65Hz out F is displayed Table 7 7 Inrush current Function Range Accuracy ACA 99 99 A 3 0 3 A 599 9 A 3 5 dgt For measured val...

Страница 43: ...599 9 kW 10 V 5 A min 1 The range is determined by the V A range 9 999 kW 100 V 100 A 99 99 kW 1000 V 100 A or 100 V 600 A 599 9 kW 1000 V 600 A Overload protection 1000 Vrms 600 Arms Accuracy defined...

Страница 44: ...00 Vrms Maximum test current Approx 0 5 mA Maximum open circuit voltage for Approx 2 4 V Maximum open circuit voltage for diode Approx 1 6 V Continuity threshold 30 beep on 100 beep off Continuity ind...

Страница 45: ...Technical support for external meters Website http www flir com test Technical support TMSupport flir com Repairs Repair flir com Phone number 1 855 499 3662 toll free T559825 r AI 33557 33557 en US 3...

Страница 46: ...he applicable Warranty Period PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY AT FLIR S SOLE DISCRE TION IS THE REPAIR OR REPLACEMENT OF DEFECTIVE PRODUCTS IN A MANNER AND BY A SERVICE CENTE...

Страница 47: ...EXCLUSIONS AND DISCLAIMERS 1 PRODUCT REGISTRATION To qualify for FLIR s Lim ited Warranty Purchaser must fully register the Product di rectly with FLIR on line at http www flir com within Sixty 60 DA...

Страница 48: ...etermine in its sole discretion whether a returned Product is covered under Warranty If FLIR determines that any returned Product is not covered under Warranty or is otherwise excluded from Warranty c...

Страница 49: ......

Страница 50: ...e For more information about XML please visit http www w3 org XML A note on the typeface used in this publication This publication was typeset using Linotype Helvetica World Helvetica was designed by...

Страница 51: ......

Страница 52: ...support flir com Copyright 2016 FLIR Systems Inc All rights reserved worldwide Disclaimer Specifications subject to change without further notice Models and accessories subject to regional market cons...

Отзывы: