FT-13 Technical Manual, Rev. 1.40 March 2013
Page 25 of 56
7.3.7 Programme 6: Filling and Emptying Type 2
F T -1 3
F T -1 3
Application:
Bagging machines
Material feeding systems
The filling stops if the total weight is higher than
the entered total limit value
Operation:
The tank/hopper is filled up to the target value
accurately by 2-speed or 3-speed filling.
The discharge input starts the complete emtying
of the tank/hopper and the weight is totalized.
Filling and emptying must be in sequence.
If the actual total weight is higher than the total
target value, the filling does not start.
For non-legal for trade discontinuous totalizer
applications, use the fine feed output for charging
and the parameters should be entered as:
Target = Tolerance
Coarse = Fine = 0
[501]=00
Process Parameters
Description
+
+
+
When type FT-
13 is in the “Ready” status (the top LED in
the LED bar is “on” ) press the keys shown on the left
sequentially.
This is the delay time at the end of emptying. The bottom
gate is opened and emtying starts. When the weight goes
into the zero range, “
d_dıSC
“ delay starts and the gate is
closed at the end of this period. The delay time can be
entered by the keypad up to 9.9 s.
If the gate position control is enabled and after the start
input> is activated, the gate position will be checked at the
end of this period.
It can be entered by the keypad up to 25.0 s.
Emptying type.
If it is set to “1“, the weight is followed during emptying.
Wh
en the weight goes into the zero range, the “d_dıSC”
delay starts and the gate is closed at the end of this delay.
If it is set to “0“, only the “d-dıSC” delay is enabled and the
gate is left open during the “d_dıSC” period.
Gate position check
0 = No
1 = “Gate position control” is enabled
This is the requested total weight. If the totalized weight is
higher than the requested total weight, the filling does not
start and the process ends. The value is entered in “kg”
without floating point. Enter “0” to disable the total check.
Zero range.
If the weigh is in this range, it means the scale is empty. To
start filling the weight has to be in the zero range.
Exit
t_trGT
XXXXX
d_dıSC
X.X
d_GAtE
X.X
E_tYPE
X
ZEro_r
XXXXX
GAT_Ch
k
X