FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 73 of 131
CHK (Checksum) = 0
– ( STX
+
STATUS A
+
.....
+
LF)
Error Messages: UNDER, OVER, A.OUT, L-VOLT, H-VOLT, are represented in Indicated data fields.
Note:
The weight data is represented with right aligned and the error messages are represented with left
aligned.
9.2 Fast Continuous Data Output
Fast continuous “indicated weight” data output can be used only for the instruments which can communicate
fast. The output rate is related with the baud rate. Use higher baud rate for faster data rate. Received ASCII
codes of
P
(print),
Z
(zero),
T
(tare) or
C
(clear) letters, the controller will act like the related keys are pressed.
CR and LF can be enabled in the related parameter.
The data format of the fast continuous data output is;
[STX][STATUS][SIGN][WEIGHT VALUE][CR][LF]
Examples
:
S+000123.4
(weight is stable and 123.4)
D+000123.4
(weight is dynamic and 123.4)
+
(Over load)
-
(Under load)
O
(ADC out error)
9.3 Print Mode
The format of the data output in Print mode can be selected in 3 different type forms in the parameter group
[
04-
]. Only continuous format is available more than one interface. The print mode output is transmitted
automatically after each filling or by pressing <
> key in basic weighing mode (ready status).
Single Line
You can send the data in single line like below by pressing <
Enter
> key.
CN: 21 G: 3.000kg T: 1.000kg N: 2.000kg
Multi Line Formats
You can send the data in multiple lines as seen in the label given below by pressing <
Enter
> key.
The data output structure can be programmed with printer parameters for 2 different printer types.
Multi Line-24 Format
Multi Line-16 Format
CN
GROSS
TARE
NET
M
S
D
L
S
D
S
P
M
S
D
L
S
D
S
P
M
S
D
L
S
D
S
P
M
S
D
L
S
D
L
F
C
R
9
3
13
3
13
3
13
1
1